M Eremchev, D Roesel, P-M Dansette, A Michailovas, S Roke
{"title":"巨型单层囊泡的高通量宽场二次谐波成像。","authors":"M Eremchev, D Roesel, P-M Dansette, A Michailovas, S Roke","doi":"10.1116/6.0002640","DOIUrl":null,"url":null,"abstract":"<p><p>Cell-sized giant unilamellar vesicles (GUVs) are an ideal tool for understanding lipid membrane structure and properties. Label-free spatiotemporal images of their membrane potential and structure would greatly aid the quantitative understanding of membrane properties. In principle, second harmonic imaging is a great tool to do so, but the low degree of spatial anisotropy that arises from a single membrane limits its application. Here, we advance the use of wide-field high throughput SH imaging by SH imaging with the use of ultrashort laser pulses. We achieve a throughput improvement of 78% of the maximum theoretical value and demonstrate subsecond image acquisition times. We show how the interfacial water intensity can be converted into a quantitative membrane potential map. Finally, for GUV imaging, we compare this type of nonresonant SH imaging to resonant SH imaging and two photon imaging using fluorophores.</p>","PeriodicalId":9053,"journal":{"name":"Biointerphases","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"High throughput wide field second harmonic imaging of giant unilamellar vesicles.\",\"authors\":\"M Eremchev, D Roesel, P-M Dansette, A Michailovas, S Roke\",\"doi\":\"10.1116/6.0002640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Cell-sized giant unilamellar vesicles (GUVs) are an ideal tool for understanding lipid membrane structure and properties. Label-free spatiotemporal images of their membrane potential and structure would greatly aid the quantitative understanding of membrane properties. In principle, second harmonic imaging is a great tool to do so, but the low degree of spatial anisotropy that arises from a single membrane limits its application. Here, we advance the use of wide-field high throughput SH imaging by SH imaging with the use of ultrashort laser pulses. We achieve a throughput improvement of 78% of the maximum theoretical value and demonstrate subsecond image acquisition times. We show how the interfacial water intensity can be converted into a quantitative membrane potential map. Finally, for GUV imaging, we compare this type of nonresonant SH imaging to resonant SH imaging and two photon imaging using fluorophores.</p>\",\"PeriodicalId\":9053,\"journal\":{\"name\":\"Biointerphases\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biointerphases\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1116/6.0002640\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biointerphases","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1116/6.0002640","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
High throughput wide field second harmonic imaging of giant unilamellar vesicles.
Cell-sized giant unilamellar vesicles (GUVs) are an ideal tool for understanding lipid membrane structure and properties. Label-free spatiotemporal images of their membrane potential and structure would greatly aid the quantitative understanding of membrane properties. In principle, second harmonic imaging is a great tool to do so, but the low degree of spatial anisotropy that arises from a single membrane limits its application. Here, we advance the use of wide-field high throughput SH imaging by SH imaging with the use of ultrashort laser pulses. We achieve a throughput improvement of 78% of the maximum theoretical value and demonstrate subsecond image acquisition times. We show how the interfacial water intensity can be converted into a quantitative membrane potential map. Finally, for GUV imaging, we compare this type of nonresonant SH imaging to resonant SH imaging and two photon imaging using fluorophores.
期刊介绍:
Biointerphases emphasizes quantitative characterization of biomaterials and biological interfaces. As an interdisciplinary journal, a strong foundation of chemistry, physics, biology, engineering, theory, and/or modelling is incorporated into originated articles, reviews, and opinionated essays. In addition to regular submissions, the journal regularly features In Focus sections, targeted on specific topics and edited by experts in the field. Biointerphases is an international journal with excellence in scientific peer-review. Biointerphases is indexed in PubMed and the Science Citation Index (Clarivate Analytics). Accepted papers appear online immediately after proof processing and are uploaded to key citation sources daily. The journal is based on a mixed subscription and open-access model: Typically, authors can publish without any page charges but if the authors wish to publish open access, they can do so for a modest fee.
Topics include:
bio-surface modification
nano-bio interface
protein-surface interactions
cell-surface interactions
in vivo and in vitro systems
biofilms / biofouling
biosensors / biodiagnostics
bio on a chip
coatings
interface spectroscopy
biotribology / biorheology
molecular recognition
ambient diagnostic methods
interface modelling
adhesion phenomena.