编码愈合基台在修复单个即刻种植体美学区中的应用:一个临床病例报告。

IF 1.5 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Oral Implantology Pub Date : 2023-06-01 DOI:10.1563/aaid-joi-D-22-00187
Esraa A Attar
{"title":"编码愈合基台在修复单个即刻种植体美学区中的应用:一个临床病例报告。","authors":"Esraa A Attar","doi":"10.1563/aaid-joi-D-22-00187","DOIUrl":null,"url":null,"abstract":"<p><p>For several years, the implant-level impression procedure started by removal of the healing abutment, followed by connection of the impression coping to the implant. Encode Complete (Encode, Biomet 3i, Biomet 3i, Palm Beach Gardens, FL) was introduced to eliminate implant-level impressions by offering a healing abutment-level impression protocol. This report illustrated the treatment of a single tooth in the anterior esthetic zone using Encode Complete. A 23-year-old female patient reported to the prosthodontics clinic complaining of a fractured maxillary anterior tooth that was deemed nonrestorable. After immediate implant placement, soft tissue preservation and temporization of the implant, healing abutment level impression was made. The codes embedded on the occlusal surface communicated the implant depth, hex-orientation, platform diameter, and interface. The definitive Encode gold-plated titanium abutment was anatomically designed virtually with customized margin, contour, taper, and emergence profile. The milling process was initiated, and the virtual design data were sent to the Robocast Center for analog placement in the original Encode master cast. The definitive abutment was placed on the master cast using Robocast technology, followed by the fabrication of the final porcelain fused to zirconia cement-retained all ceramic crown. The abutment was secured to the implant with a Gold-Tite abutment screw, followed by the final cement-retained implant crown placement. Recall visits were obtained at 1 week, 1 month, 3 months, and 1 year after final prosthesis insertion.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 3","pages":"279-285"},"PeriodicalIF":1.5000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Use of a Coded Healing Abutment in the Restoration of a Single, Immediately Placed Implant in the Esthetic Zone: A Clinical Case Report.\",\"authors\":\"Esraa A Attar\",\"doi\":\"10.1563/aaid-joi-D-22-00187\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>For several years, the implant-level impression procedure started by removal of the healing abutment, followed by connection of the impression coping to the implant. Encode Complete (Encode, Biomet 3i, Biomet 3i, Palm Beach Gardens, FL) was introduced to eliminate implant-level impressions by offering a healing abutment-level impression protocol. This report illustrated the treatment of a single tooth in the anterior esthetic zone using Encode Complete. A 23-year-old female patient reported to the prosthodontics clinic complaining of a fractured maxillary anterior tooth that was deemed nonrestorable. After immediate implant placement, soft tissue preservation and temporization of the implant, healing abutment level impression was made. The codes embedded on the occlusal surface communicated the implant depth, hex-orientation, platform diameter, and interface. The definitive Encode gold-plated titanium abutment was anatomically designed virtually with customized margin, contour, taper, and emergence profile. The milling process was initiated, and the virtual design data were sent to the Robocast Center for analog placement in the original Encode master cast. The definitive abutment was placed on the master cast using Robocast technology, followed by the fabrication of the final porcelain fused to zirconia cement-retained all ceramic crown. The abutment was secured to the implant with a Gold-Tite abutment screw, followed by the final cement-retained implant crown placement. Recall visits were obtained at 1 week, 1 month, 3 months, and 1 year after final prosthesis insertion.</p>\",\"PeriodicalId\":50101,\"journal\":{\"name\":\"Journal of Oral Implantology\",\"volume\":\"49 3\",\"pages\":\"279-285\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Oral Implantology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1563/aaid-joi-D-22-00187\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oral Implantology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-22-00187","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

几年来,种植体水平的印模手术从移除愈合基台开始,然后将印模顶部连接到种植体上。Encode Complete (Encode, Biomet 3i, Biomet 3i, Palm Beach Gardens, FL)通过提供愈合基台级印模方案来消除种植体级印模。本报告描述了使用Encode Complete治疗单牙前感觉区。一名23岁的女性患者到口腔修复科就诊,主诉上颌前牙骨折,认为无法修复。即刻种植体放置、软组织保存及种植体暂存后,制作愈合基台水平印模。嵌套在咬合面上的编码包含种植体深度、六边形方向、平台直径和界面。最终的Encode镀金钛基台是解剖学上设计的,具有定制的边缘、轮廓、锥度和涌现轮廓。铣削过程开始,虚拟设计数据被发送到Robocast中心,在原始Encode主铸模中进行模拟放置。使用Robocast技术将最终的基台放置在主铸件上,然后制造最终的瓷融合到氧化锆水泥中,保留所有陶瓷冠。用金钛基牙螺钉将基牙固定在种植体上,然后进行最后的骨水泥保留种植体冠置入术。在最终植入假体后1周、1个月、3个月和1年进行回忆访问。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Use of a Coded Healing Abutment in the Restoration of a Single, Immediately Placed Implant in the Esthetic Zone: A Clinical Case Report.

For several years, the implant-level impression procedure started by removal of the healing abutment, followed by connection of the impression coping to the implant. Encode Complete (Encode, Biomet 3i, Biomet 3i, Palm Beach Gardens, FL) was introduced to eliminate implant-level impressions by offering a healing abutment-level impression protocol. This report illustrated the treatment of a single tooth in the anterior esthetic zone using Encode Complete. A 23-year-old female patient reported to the prosthodontics clinic complaining of a fractured maxillary anterior tooth that was deemed nonrestorable. After immediate implant placement, soft tissue preservation and temporization of the implant, healing abutment level impression was made. The codes embedded on the occlusal surface communicated the implant depth, hex-orientation, platform diameter, and interface. The definitive Encode gold-plated titanium abutment was anatomically designed virtually with customized margin, contour, taper, and emergence profile. The milling process was initiated, and the virtual design data were sent to the Robocast Center for analog placement in the original Encode master cast. The definitive abutment was placed on the master cast using Robocast technology, followed by the fabrication of the final porcelain fused to zirconia cement-retained all ceramic crown. The abutment was secured to the implant with a Gold-Tite abutment screw, followed by the final cement-retained implant crown placement. Recall visits were obtained at 1 week, 1 month, 3 months, and 1 year after final prosthesis insertion.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Oral Implantology
Journal of Oral Implantology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.30
自引率
6.20%
发文量
54
审稿时长
6-12 weeks
期刊介绍: The official publication of the American Academy of Implant Dentistry and of the American Academy of Implant Prosthodontics, is dedicated to providing valuable information to general dentists, oral surgeons, prosthodontists, periodontists, scientists, clinicians, laboratory owners and technicians, manufacturers, and educators. Implant basics, prosthetics, pharmaceuticals, the latest research in implantology, implant surgery, and advanced implant procedures are just some of the topics covered.
期刊最新文献
Comparison of Biomechanical Behaviors of Different Designs and Configurations of Titanium and Zirconium Dental Implants With Finite Elements Analysis in Anterior Maxilla. Enhancing Precision and Efficiency in Fabricating Complete Arch Screw-Retained Implant Prosthesis: A Clinical Case Report Utilizing the Nexus iOS Scan Gauge System. Reconstruction of the Fully Edentulous Maxilla Using Sinus Grafts and Bone Expansion: A Retrospective Analysis of 50 Consecutive Cases. All-on-4 Concept With Use Of Zygoma Implants for Rehabilitation in the Severely Atrophied Maxilla With a Definitive Immediate Restoration. Clinical Performance of 170 Frictional Morse Taper Implants: 2 Years Follow-Up.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1