Zachary P Berliner, Muhammad Umar Jawad, Chelsea Matzko, H John Cooper, Jose A Rodriguez, Matthew S Hepinstall
{"title":"全羟基磷灰石涂层锥形股骨柄周围的近端放射线:我们应该关注吗?","authors":"Zachary P Berliner, Muhammad Umar Jawad, Chelsea Matzko, H John Cooper, Jose A Rodriguez, Matthew S Hepinstall","doi":"10.1177/11207000231178269","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Radiolucent lines occasionally develop around the proximal aspect of fully hydroxyapatite (HA)-coated tapered femoral stems after total hip arthroplasty (THA). It was hypothesised that distal wedging of stems may predispose to proximal radiolucent line formation, which may negatively impact clinical outcome.</p><p><strong>Methods: </strong>All primary THA performed with a collarless fully HA-coated stem that had a minimum of 1 year of radiographic follow-up were identified in a surgical database (<i>n =</i> 244). Radiographic measures of proximal femoral morphology and femoral canal fill at the middle and distal thirds of the stem were analysed for association with the presence of proximal radiolucent lines. Linear regression was used to explore any association between radiolucent lines and patient reported outcome measures (PROMs), available in 61% of patients.</p><p><strong>Results: </strong>Proximal radiolucent lines developed in 31 cases (12.7%) at final follow-up. Dorr A femoral morphology and increased canal-fill at the distal ⅓ of the stem correlated with the development of radiolucent lines (<i>p <</i> 0.001). No correlation was observed between pain or PROMs and the presence of proximal radiolucent lines.</p><p><strong>Discussion: </strong>We observed an unexpectedly high incidence of proximal femoral radiolucent lines about collarless fully HA coated stems. Distal-only implant wedging in Dorr A bone may compromise proximal fixation. Although this finding did not correlate with short-term outcomes, the long-term clinical impact requires further study.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proximal radiolucent lines around fully hydroxyapatite-coated tapered femoral stems: should we be concerned?\",\"authors\":\"Zachary P Berliner, Muhammad Umar Jawad, Chelsea Matzko, H John Cooper, Jose A Rodriguez, Matthew S Hepinstall\",\"doi\":\"10.1177/11207000231178269\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Radiolucent lines occasionally develop around the proximal aspect of fully hydroxyapatite (HA)-coated tapered femoral stems after total hip arthroplasty (THA). It was hypothesised that distal wedging of stems may predispose to proximal radiolucent line formation, which may negatively impact clinical outcome.</p><p><strong>Methods: </strong>All primary THA performed with a collarless fully HA-coated stem that had a minimum of 1 year of radiographic follow-up were identified in a surgical database (<i>n =</i> 244). Radiographic measures of proximal femoral morphology and femoral canal fill at the middle and distal thirds of the stem were analysed for association with the presence of proximal radiolucent lines. Linear regression was used to explore any association between radiolucent lines and patient reported outcome measures (PROMs), available in 61% of patients.</p><p><strong>Results: </strong>Proximal radiolucent lines developed in 31 cases (12.7%) at final follow-up. Dorr A femoral morphology and increased canal-fill at the distal ⅓ of the stem correlated with the development of radiolucent lines (<i>p <</i> 0.001). No correlation was observed between pain or PROMs and the presence of proximal radiolucent lines.</p><p><strong>Discussion: </strong>We observed an unexpectedly high incidence of proximal femoral radiolucent lines about collarless fully HA coated stems. Distal-only implant wedging in Dorr A bone may compromise proximal fixation. Although this finding did not correlate with short-term outcomes, the long-term clinical impact requires further study.</p>\",\"PeriodicalId\":12911,\"journal\":{\"name\":\"HIP International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HIP International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11207000231178269\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000231178269","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Proximal radiolucent lines around fully hydroxyapatite-coated tapered femoral stems: should we be concerned?
Introduction: Radiolucent lines occasionally develop around the proximal aspect of fully hydroxyapatite (HA)-coated tapered femoral stems after total hip arthroplasty (THA). It was hypothesised that distal wedging of stems may predispose to proximal radiolucent line formation, which may negatively impact clinical outcome.
Methods: All primary THA performed with a collarless fully HA-coated stem that had a minimum of 1 year of radiographic follow-up were identified in a surgical database (n = 244). Radiographic measures of proximal femoral morphology and femoral canal fill at the middle and distal thirds of the stem were analysed for association with the presence of proximal radiolucent lines. Linear regression was used to explore any association between radiolucent lines and patient reported outcome measures (PROMs), available in 61% of patients.
Results: Proximal radiolucent lines developed in 31 cases (12.7%) at final follow-up. Dorr A femoral morphology and increased canal-fill at the distal ⅓ of the stem correlated with the development of radiolucent lines (p < 0.001). No correlation was observed between pain or PROMs and the presence of proximal radiolucent lines.
Discussion: We observed an unexpectedly high incidence of proximal femoral radiolucent lines about collarless fully HA coated stems. Distal-only implant wedging in Dorr A bone may compromise proximal fixation. Although this finding did not correlate with short-term outcomes, the long-term clinical impact requires further study.
期刊介绍:
HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice.
The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit.
HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are:
• Biomaterials
• Biomechanics
• Conservative Hip Surgery
• Paediatrics
• Primary and Revision Hip Arthroplasty
• Traumatology