{"title":"新开发的低剂量 180 度 CBCT 方案可在不影响诊断价值的情况下减少辐射剂量。","authors":"Afroditi Pita, Sejal Thacker, Takanori Sobue, Vaibhav Gandhi, Aditya Tadinada","doi":"10.11607/jomi.10364","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the standard 360-degree CBCT acquisition protocol to the low dose 180-degree CBCT protocol for implant planning.</p><p><strong>Materials and methods: </strong>Two groups of patients, each consisting of 35 patients, were included in the study. The first group was imaged with the conventional 360-degree CBCT protocol, and the second group was imaged with the low dose 180-degree CBCT protocol. The primary outcome of this study was the number of scans that needed to be repeated due to poor image quality. In addition, six secondary parameters were evaluated quantitatively and qualitatively.</p><p><strong>Results: </strong>The results showed that there was no need to repeat any of the CBCT scans that were obtained in either group, which showed that 360-degree and 180-degree protocols had comparable image quality. As for the secondary parameters, the results showed that the evaluators were able to evaluate the six chosen parameters in a comparable manner.</p><p><strong>Conclusion: </strong>The 180-degree low dose CBCT scan is a viable option for dental implant treatment planning in the posterior mandible as it provides comparable and adequate information regarding accuracy of measurements, identification of critical structures, evaluation of bone quality, and any pathology.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Newly Developed Low Dose 180-degree CBCT Protocol Reduces Radiation Dose Without Compromising Diagnostic Value.\",\"authors\":\"Afroditi Pita, Sejal Thacker, Takanori Sobue, Vaibhav Gandhi, Aditya Tadinada\",\"doi\":\"10.11607/jomi.10364\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare the standard 360-degree CBCT acquisition protocol to the low dose 180-degree CBCT protocol for implant planning.</p><p><strong>Materials and methods: </strong>Two groups of patients, each consisting of 35 patients, were included in the study. The first group was imaged with the conventional 360-degree CBCT protocol, and the second group was imaged with the low dose 180-degree CBCT protocol. The primary outcome of this study was the number of scans that needed to be repeated due to poor image quality. In addition, six secondary parameters were evaluated quantitatively and qualitatively.</p><p><strong>Results: </strong>The results showed that there was no need to repeat any of the CBCT scans that were obtained in either group, which showed that 360-degree and 180-degree protocols had comparable image quality. As for the secondary parameters, the results showed that the evaluators were able to evaluate the six chosen parameters in a comparable manner.</p><p><strong>Conclusion: </strong>The 180-degree low dose CBCT scan is a viable option for dental implant treatment planning in the posterior mandible as it provides comparable and adequate information regarding accuracy of measurements, identification of critical structures, evaluation of bone quality, and any pathology.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/jomi.10364\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.10364","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Newly Developed Low Dose 180-degree CBCT Protocol Reduces Radiation Dose Without Compromising Diagnostic Value.
Purpose: To compare the standard 360-degree CBCT acquisition protocol to the low dose 180-degree CBCT protocol for implant planning.
Materials and methods: Two groups of patients, each consisting of 35 patients, were included in the study. The first group was imaged with the conventional 360-degree CBCT protocol, and the second group was imaged with the low dose 180-degree CBCT protocol. The primary outcome of this study was the number of scans that needed to be repeated due to poor image quality. In addition, six secondary parameters were evaluated quantitatively and qualitatively.
Results: The results showed that there was no need to repeat any of the CBCT scans that were obtained in either group, which showed that 360-degree and 180-degree protocols had comparable image quality. As for the secondary parameters, the results showed that the evaluators were able to evaluate the six chosen parameters in a comparable manner.
Conclusion: The 180-degree low dose CBCT scan is a viable option for dental implant treatment planning in the posterior mandible as it provides comparable and adequate information regarding accuracy of measurements, identification of critical structures, evaluation of bone quality, and any pathology.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.