Rahman Ali, Anas Ilyas, Hizbullah Riaz, Umer Faheem, Junaid Khan, Naeem Ahmed, Ahmed Aziz
{"title":"跨腕外固定架与支撑钢板治疗桡骨远端骨折的疗效比较。","authors":"Rahman Ali, Anas Ilyas, Hizbullah Riaz, Umer Faheem, Junaid Khan, Naeem Ahmed, Ahmed Aziz","doi":"10.55519/JAMC-01-10605","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Distal radius fracture is one of the most common injuries presented to emergency department and can be presented in any age group. In young patients the most common cause is Road Traffic Accident (RTA), while old patient history of fall is the most common cause. Different surgical options are available to treat this injury. This study aims to compare the outcome of volar buttress plate vs across wrist external fixator for Arbeitsgemeinschaft für Osteosynthesefragen (AO) type C2/C3 fracture of the distal radius.</p><p><strong>Methods: </strong>A retrospective comparative study between July 2020 to June 2021 at Ghurki Trust Teaching Hospital was done and a total of 50 patients who underwent surgical intervention for AO C2/C3 fracture of the distal Radius, were included. The follow-up period was 12 weeks. QuickDASH score was used to find out patient's functional outcomes. Functional outcome was analyzed between the two groups using Mann-Whitney U test, using SPSS version 21.</p><p><strong>Results: </strong>There was no significant statistical difference between the functional outcome of patients with distal radius fracture treated with across wrist external fixator vs volar buttress plate, in term of QuickDASH score. Furthermore, age and gender also were having no effect on functional outcome in our population.</p><p><strong>Conclusions: </strong>Across wrist external fixator is a reasonable option for AO C2/C3 type fractures of the distal radius with comparable results with volar buttress plate. It is the procedure of choice in high volume tertiary care hospitals like Gurki Trust Teaching hospital as it saves time, have similar functional outcome score, no need to re-open for removal of implant, less chances of tendon rupture as compared to volar buttress plate for distal radius fracture.</p>","PeriodicalId":15141,"journal":{"name":"Journal of Ayub Medical College, Abbottabad : JAMC","volume":"35 1","pages":"32-36"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Outcome Of The Distal Radius Fractures Managed With Across Wrist External Fixator Vs Buttress Plates.\",\"authors\":\"Rahman Ali, Anas Ilyas, Hizbullah Riaz, Umer Faheem, Junaid Khan, Naeem Ahmed, Ahmed Aziz\",\"doi\":\"10.55519/JAMC-01-10605\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Distal radius fracture is one of the most common injuries presented to emergency department and can be presented in any age group. In young patients the most common cause is Road Traffic Accident (RTA), while old patient history of fall is the most common cause. Different surgical options are available to treat this injury. This study aims to compare the outcome of volar buttress plate vs across wrist external fixator for Arbeitsgemeinschaft für Osteosynthesefragen (AO) type C2/C3 fracture of the distal radius.</p><p><strong>Methods: </strong>A retrospective comparative study between July 2020 to June 2021 at Ghurki Trust Teaching Hospital was done and a total of 50 patients who underwent surgical intervention for AO C2/C3 fracture of the distal Radius, were included. The follow-up period was 12 weeks. QuickDASH score was used to find out patient's functional outcomes. Functional outcome was analyzed between the two groups using Mann-Whitney U test, using SPSS version 21.</p><p><strong>Results: </strong>There was no significant statistical difference between the functional outcome of patients with distal radius fracture treated with across wrist external fixator vs volar buttress plate, in term of QuickDASH score. Furthermore, age and gender also were having no effect on functional outcome in our population.</p><p><strong>Conclusions: </strong>Across wrist external fixator is a reasonable option for AO C2/C3 type fractures of the distal radius with comparable results with volar buttress plate. It is the procedure of choice in high volume tertiary care hospitals like Gurki Trust Teaching hospital as it saves time, have similar functional outcome score, no need to re-open for removal of implant, less chances of tendon rupture as compared to volar buttress plate for distal radius fracture.</p>\",\"PeriodicalId\":15141,\"journal\":{\"name\":\"Journal of Ayub Medical College, Abbottabad : JAMC\",\"volume\":\"35 1\",\"pages\":\"32-36\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ayub Medical College, Abbottabad : JAMC\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.55519/JAMC-01-10605\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ayub Medical College, Abbottabad : JAMC","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55519/JAMC-01-10605","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
背景:桡骨远端骨折是急诊科最常见的损伤之一,任何年龄段都可能发生。在年轻患者中,最常见的原因是道路交通事故(RTA),而老年患者跌倒史是最常见的病因。治疗这种损伤有不同的手术选择。本研究旨在比较掌侧支撑板与跨腕外固定器治疗桡骨远端Arbeitsgemeinschaft für Osteo-synthesefragen(AO)型C2/C3骨折的疗效。方法:2020年7月至2021年6月在古尔基信托教学医院进行了一项回顾性比较研究,共有50名患者接受了桡骨远端AO C2/C3骨折的手术干预。随访时间为12周。QuickDASH评分用于了解患者的功能结果。使用SPSS 21版Mann-Whitney U检验对两组患者的功能结果进行分析。结果:在QuickDASH评分方面,使用跨腕外固定器治疗桡骨远端骨折的患者与使用掌侧支撑板治疗的桡骨远端骨折患者的功能结果之间没有显著的统计学差异。此外,年龄和性别对我们人群的功能结果也没有影响。结论:跨腕外固定器治疗桡骨远端AO C2/C3型骨折是一种合理的选择,与掌侧支撑钢板疗效相当。这是像Gurki Trust Teaching医院这样的大容量三级护理医院的首选手术,因为与桡骨远端骨折的掌侧支撑板相比,它节省了时间,具有相似的功能结果评分,无需重新开放以移除植入物,肌腱断裂的机会更小。
Outcome Of The Distal Radius Fractures Managed With Across Wrist External Fixator Vs Buttress Plates.
Background: Distal radius fracture is one of the most common injuries presented to emergency department and can be presented in any age group. In young patients the most common cause is Road Traffic Accident (RTA), while old patient history of fall is the most common cause. Different surgical options are available to treat this injury. This study aims to compare the outcome of volar buttress plate vs across wrist external fixator for Arbeitsgemeinschaft für Osteosynthesefragen (AO) type C2/C3 fracture of the distal radius.
Methods: A retrospective comparative study between July 2020 to June 2021 at Ghurki Trust Teaching Hospital was done and a total of 50 patients who underwent surgical intervention for AO C2/C3 fracture of the distal Radius, were included. The follow-up period was 12 weeks. QuickDASH score was used to find out patient's functional outcomes. Functional outcome was analyzed between the two groups using Mann-Whitney U test, using SPSS version 21.
Results: There was no significant statistical difference between the functional outcome of patients with distal radius fracture treated with across wrist external fixator vs volar buttress plate, in term of QuickDASH score. Furthermore, age and gender also were having no effect on functional outcome in our population.
Conclusions: Across wrist external fixator is a reasonable option for AO C2/C3 type fractures of the distal radius with comparable results with volar buttress plate. It is the procedure of choice in high volume tertiary care hospitals like Gurki Trust Teaching hospital as it saves time, have similar functional outcome score, no need to re-open for removal of implant, less chances of tendon rupture as compared to volar buttress plate for distal radius fracture.