Philip Keye, Thomas Reinhard, Philip Christian Maier
{"title":"人工虹膜眼的去角膜内皮角膜移植术","authors":"Philip Keye, Thomas Reinhard, Philip Christian Maier","doi":"10.1055/a-2089-3588","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study is to report the outcome of Descemet membrane endothelial keratoplasty (DMEK) in three eyes with a complex anterior segment and an artificial iris. A retrospective chart review of three cases was performed and clinically meaningful patient characteristics, clinical events, and therapeutic interventions were outlined. A literature search was performed and the clinical course of the three cases was discussed in the context of the published literature. DMEK in the presence of an artificial iris did not match the clinical results of DMEK in uncomplicated eyes. All three eyes experienced major complications, such as failure to achieve graft adherence, early graft failure, or an immune reaction. The indication for DMEK in complex anterior segments with an artificial iris should be made with the awareness of multiple possible complications and the potentially poor prognosis of the procedure.</p>","PeriodicalId":17904,"journal":{"name":"Klinische Monatsblatter fur Augenheilkunde","volume":" ","pages":"741-743"},"PeriodicalIF":0.8000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Descemet Membrane Endothelial Keratoplasty in Eyes with an Artificial Iris.\",\"authors\":\"Philip Keye, Thomas Reinhard, Philip Christian Maier\",\"doi\":\"10.1055/a-2089-3588\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study is to report the outcome of Descemet membrane endothelial keratoplasty (DMEK) in three eyes with a complex anterior segment and an artificial iris. A retrospective chart review of three cases was performed and clinically meaningful patient characteristics, clinical events, and therapeutic interventions were outlined. A literature search was performed and the clinical course of the three cases was discussed in the context of the published literature. DMEK in the presence of an artificial iris did not match the clinical results of DMEK in uncomplicated eyes. All three eyes experienced major complications, such as failure to achieve graft adherence, early graft failure, or an immune reaction. The indication for DMEK in complex anterior segments with an artificial iris should be made with the awareness of multiple possible complications and the potentially poor prognosis of the procedure.</p>\",\"PeriodicalId\":17904,\"journal\":{\"name\":\"Klinische Monatsblatter fur Augenheilkunde\",\"volume\":\" \",\"pages\":\"741-743\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Klinische Monatsblatter fur Augenheilkunde\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2089-3588\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/6/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Klinische Monatsblatter fur Augenheilkunde","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2089-3588","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/30 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Descemet Membrane Endothelial Keratoplasty in Eyes with an Artificial Iris.
The purpose of this study is to report the outcome of Descemet membrane endothelial keratoplasty (DMEK) in three eyes with a complex anterior segment and an artificial iris. A retrospective chart review of three cases was performed and clinically meaningful patient characteristics, clinical events, and therapeutic interventions were outlined. A literature search was performed and the clinical course of the three cases was discussed in the context of the published literature. DMEK in the presence of an artificial iris did not match the clinical results of DMEK in uncomplicated eyes. All three eyes experienced major complications, such as failure to achieve graft adherence, early graft failure, or an immune reaction. The indication for DMEK in complex anterior segments with an artificial iris should be made with the awareness of multiple possible complications and the potentially poor prognosis of the procedure.
期刊介绍:
-Konzentriertes Fachwissen aus Klinik und Praxis:
Die entscheidenden Ergebnisse der internationalen Forschung - für Sie auf den Punkt gebracht und kritisch kommentiert,
Übersichtsarbeiten zu den maßgeblichen Themen der täglichen Praxis,
Top informiert - breite klinische Berichterstattung.
-CME-Punkte sammeln mit dem Refresher:
Effiziente, CME-zertifizierte Fortbildung, mit dem Refresher,
3 CME-Punkte pro Ausgabe - bis zu 36 CME-Punkte im Jahr!.
-Aktuelle Rubriken mit echtem Nutzwert:
Kurzreferate zu den wichtigsten Artikeln internationaler Zeitschriften,
Schwerpunktthema in jedem Heft: Ausführliche Übersichtsarbeiten zu den wichtigsten Themen der Ophthalmologie – so behalten Sie das gesamte Fach im Blick!,
Originalien mit den neuesten Entwicklungen,
Übersichten zu den relevanten Themen.