验证的qrs极性算法,特别强调在parahisian路径。

IF 0.7 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS Archivos de cardiologia de Mexico Pub Date : 2023-01-01 DOI:10.24875/ACM.22000090
Jorge Gómez-Flores, Ángel Cueva-Parra, Antonio Gallegos-Cortéz, Santiago Nava, Manlio F Márquez, Pedro Iturralde-Torres
{"title":"验证的qrs极性算法,特别强调在parahisian路径。","authors":"Jorge Gómez-Flores,&nbsp;Ángel Cueva-Parra,&nbsp;Antonio Gallegos-Cortéz,&nbsp;Santiago Nava,&nbsp;Manlio F Márquez,&nbsp;Pedro Iturralde-Torres","doi":"10.24875/ACM.22000090","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In 1996 Iturralde et al. published an algorithm based on the QRS polarity to determine the location of the accessory pathways (AP), this algorithm was developed before the massive practice of invasive electrophysiology.</p><p><strong>Purpose: </strong>To validate the QRS-Polarity algorithm in a modern cohort of subjects submitted to radiofrequency catheter ablation (RFCA). Our objective was to determinate its global accuracy and its accuracy for parahisian AP.</p><p><strong>Methods: </strong>We conducted a retrospective analysis of patients with Wolff-Parkinson-White (WPW) syndrome who underwent an electrophysiological study (EPS) and RFCA. We employed the QRS-Polarity algorithm to predict the AP anatomical location and we compared this result with the real anatomic location determined in the EPS. To determine accuracy, the Cohen's kappa coefficient (k) and the Pearson correlation coefficient were used.</p><p><strong>Results: </strong>A total of 364 patients were included (mean age 30 years, 57% male). The global k score was 0.78 and the Pearson's coefficient was 0.90. The accuracy for each zone was also evaluated, the best correlation was for the left lateral AP (k of 0.97). There were 26 patients with a parahisian AP, who showed a great variability in the ECG features. Employing the QRS-Polarity algorithm, 34.6% patients had a correct anatomical location, 42.3% had an adjacent location and only 23% an incorrect location.</p><p><strong>Conclusion: </strong>The QRS-Polarity algorithm has a good global accuracy; its precision is high, especially for left lateral AP. This algorithm is also useful for the parahisian AP.</p>","PeriodicalId":8360,"journal":{"name":"Archivos de cardiologia de Mexico","volume":"93 2","pages":"164-171"},"PeriodicalIF":0.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b8/77/7567AX222-ACM-93-164.PMC10161820.pdf","citationCount":"0","resultStr":"{\"title\":\"Validation of qrs-polarity algorithm with special emphasis in parahisian pathways.\",\"authors\":\"Jorge Gómez-Flores,&nbsp;Ángel Cueva-Parra,&nbsp;Antonio Gallegos-Cortéz,&nbsp;Santiago Nava,&nbsp;Manlio F Márquez,&nbsp;Pedro Iturralde-Torres\",\"doi\":\"10.24875/ACM.22000090\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In 1996 Iturralde et al. published an algorithm based on the QRS polarity to determine the location of the accessory pathways (AP), this algorithm was developed before the massive practice of invasive electrophysiology.</p><p><strong>Purpose: </strong>To validate the QRS-Polarity algorithm in a modern cohort of subjects submitted to radiofrequency catheter ablation (RFCA). Our objective was to determinate its global accuracy and its accuracy for parahisian AP.</p><p><strong>Methods: </strong>We conducted a retrospective analysis of patients with Wolff-Parkinson-White (WPW) syndrome who underwent an electrophysiological study (EPS) and RFCA. We employed the QRS-Polarity algorithm to predict the AP anatomical location and we compared this result with the real anatomic location determined in the EPS. To determine accuracy, the Cohen's kappa coefficient (k) and the Pearson correlation coefficient were used.</p><p><strong>Results: </strong>A total of 364 patients were included (mean age 30 years, 57% male). The global k score was 0.78 and the Pearson's coefficient was 0.90. The accuracy for each zone was also evaluated, the best correlation was for the left lateral AP (k of 0.97). There were 26 patients with a parahisian AP, who showed a great variability in the ECG features. Employing the QRS-Polarity algorithm, 34.6% patients had a correct anatomical location, 42.3% had an adjacent location and only 23% an incorrect location.</p><p><strong>Conclusion: </strong>The QRS-Polarity algorithm has a good global accuracy; its precision is high, especially for left lateral AP. This algorithm is also useful for the parahisian AP.</p>\",\"PeriodicalId\":8360,\"journal\":{\"name\":\"Archivos de cardiologia de Mexico\",\"volume\":\"93 2\",\"pages\":\"164-171\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b8/77/7567AX222-ACM-93-164.PMC10161820.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archivos de cardiologia de Mexico\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24875/ACM.22000090\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivos de cardiologia de Mexico","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24875/ACM.22000090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:1996年Iturralde等人发表了一种基于QRS极性确定辅助通路(AP)位置的算法,该算法是在有创电生理学大量实践之前开发的。目的:在接受射频导管消融(RFCA)的现代队列中验证qrs -极性算法。我们的目的是确定它的整体准确性和它对旁隐性ap的准确性。方法:我们对Wolff-Parkinson-White (WPW)综合征患者进行了回顾性分析,这些患者接受了电生理研究(EPS)和RFCA。我们使用QRS-Polarity算法来预测AP的解剖位置,并将该结果与EPS中确定的真实解剖位置进行比较。为了确定准确性,使用Cohen's kappa系数(k)和Pearson相关系数。结果:共纳入364例患者(平均年龄30岁,男性57%)。总体k得分为0.78,Pearson系数为0.90。每个区域的准确性也进行了评估,最好的相关性是左侧AP (k为0.97)。有26例伴发性AP,其心电图表现出很大的变异性。采用qrs - polar算法,34.6%的患者解剖位置正确,42.3%的患者解剖位置邻近,只有23%的患者解剖位置不正确。结论:QRS-Polarity算法具有较好的全局精度;该算法具有较高的精度,特别是对于左侧AP。该算法也适用于parahisian AP。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validation of qrs-polarity algorithm with special emphasis in parahisian pathways.

Background: In 1996 Iturralde et al. published an algorithm based on the QRS polarity to determine the location of the accessory pathways (AP), this algorithm was developed before the massive practice of invasive electrophysiology.

Purpose: To validate the QRS-Polarity algorithm in a modern cohort of subjects submitted to radiofrequency catheter ablation (RFCA). Our objective was to determinate its global accuracy and its accuracy for parahisian AP.

Methods: We conducted a retrospective analysis of patients with Wolff-Parkinson-White (WPW) syndrome who underwent an electrophysiological study (EPS) and RFCA. We employed the QRS-Polarity algorithm to predict the AP anatomical location and we compared this result with the real anatomic location determined in the EPS. To determine accuracy, the Cohen's kappa coefficient (k) and the Pearson correlation coefficient were used.

Results: A total of 364 patients were included (mean age 30 years, 57% male). The global k score was 0.78 and the Pearson's coefficient was 0.90. The accuracy for each zone was also evaluated, the best correlation was for the left lateral AP (k of 0.97). There were 26 patients with a parahisian AP, who showed a great variability in the ECG features. Employing the QRS-Polarity algorithm, 34.6% patients had a correct anatomical location, 42.3% had an adjacent location and only 23% an incorrect location.

Conclusion: The QRS-Polarity algorithm has a good global accuracy; its precision is high, especially for left lateral AP. This algorithm is also useful for the parahisian AP.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Archivos de cardiologia de Mexico
Archivos de cardiologia de Mexico Medicine-Cardiology and Cardiovascular Medicine
CiteScore
0.80
自引率
20.00%
发文量
176
审稿时长
18 weeks
期刊最新文献
[Assessment of coronary flow capacity by positron emission tomography in coronary artery disease]. [Acute myocardial infarction patients without COVID-19 manifestations in the pandemic may have high thrombus burden]. [Abnormal aortic origin of coronary arteries]. [Intracardiac leiomyoma]. [Comments to: Recommendations for the care of patients with heart failure and COVID-19].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1