多焦人工晶状体混合技术的视觉效果、对比敏感度和满意度:中后期结果。

Q4 Medicine Ceska a Slovenska Oftalmologie Pub Date : 2023-01-01 DOI:10.31348/2023/13
Blanco, V A Galvis Tello, Mendoza
{"title":"多焦人工晶状体混合技术的视觉效果、对比敏感度和满意度:中后期结果。","authors":"Blanco,&nbsp;V A Galvis Tello,&nbsp;Mendoza","doi":"10.31348/2023/13","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To describe clinical visual outcomes, spectacle independence, and patient satisfaction after cataract surgery with blending implantation of ReSTOR (Alcon laboratories) multifocal intraocular lenses.</p><p><strong>Material and methods: </strong>A single-arm, non-randomized prospective study assessed patients undergoing cataract surgery with ReSTOR® +2.50 intraocular lens in the dominant eye and +3.00 add in the fellow eye between January 2015 to January 2020.</p><p><strong>Results: </strong>In total, 47 patients (94 eyes) were enrolled, 28 women and 19 men. The average age at surgery time was 64 ±8 years, average postoperative follow-up was 45.4 ±7.0 months, with a minimum of 18.9 months. Postoperative binocular uncorrected distance visual acuity (UDVA) was on average 0.07 logMar (Snellen 20/24), uncorrected binocular intermediate visual acuity at 65 cm was 0.07 logMar (20/24), uncorrected binocular near visual acuity at 40 cm was 0.06 logMar (20/23). Contrast sensitivity under photopic and scotopic conditions, with and without glare, remained at the upper limit of normality. 98% of patients were quite satisfied or very satisfied. 87% did not require glasses for any activities, either at distant vision, nor at near vision.</p><p><strong>Conclusions: </strong>Cataract surgery with ReSTOR® IOL blended vision showed medium-term satisfactory visual results, achieving spectacle independence and a high level of satisfaction.</p>","PeriodicalId":39839,"journal":{"name":"Ceska a Slovenska Oftalmologie","volume":"79 2","pages":"80-85"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"VISUAL OUTCOMES, CONTRAST SENSITIVITY, AND SATISFACTION WITH MULTIFOCAL INTRAOCULAR LENS BLENDED TECHNIQUE: LATE MID-TERM RESULTS.\",\"authors\":\"Blanco,&nbsp;V A Galvis Tello,&nbsp;Mendoza\",\"doi\":\"10.31348/2023/13\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To describe clinical visual outcomes, spectacle independence, and patient satisfaction after cataract surgery with blending implantation of ReSTOR (Alcon laboratories) multifocal intraocular lenses.</p><p><strong>Material and methods: </strong>A single-arm, non-randomized prospective study assessed patients undergoing cataract surgery with ReSTOR® +2.50 intraocular lens in the dominant eye and +3.00 add in the fellow eye between January 2015 to January 2020.</p><p><strong>Results: </strong>In total, 47 patients (94 eyes) were enrolled, 28 women and 19 men. The average age at surgery time was 64 ±8 years, average postoperative follow-up was 45.4 ±7.0 months, with a minimum of 18.9 months. Postoperative binocular uncorrected distance visual acuity (UDVA) was on average 0.07 logMar (Snellen 20/24), uncorrected binocular intermediate visual acuity at 65 cm was 0.07 logMar (20/24), uncorrected binocular near visual acuity at 40 cm was 0.06 logMar (20/23). Contrast sensitivity under photopic and scotopic conditions, with and without glare, remained at the upper limit of normality. 98% of patients were quite satisfied or very satisfied. 87% did not require glasses for any activities, either at distant vision, nor at near vision.</p><p><strong>Conclusions: </strong>Cataract surgery with ReSTOR® IOL blended vision showed medium-term satisfactory visual results, achieving spectacle independence and a high level of satisfaction.</p>\",\"PeriodicalId\":39839,\"journal\":{\"name\":\"Ceska a Slovenska Oftalmologie\",\"volume\":\"79 2\",\"pages\":\"80-85\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ceska a Slovenska Oftalmologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31348/2023/13\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceska a Slovenska Oftalmologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31348/2023/13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:描述混合ReSTOR(爱尔康实验室)多焦人工晶体植入术后的临床视力结果、眼镜独立性和患者满意度。材料和方法:一项单臂、非随机前瞻性研究评估了2015年1月至2020年1月期间接受白内障手术的患者,主眼植入ReSTOR®+2.50人工晶状体,对眼植入+3.00。结果:共纳入47例患者(94只眼),其中女性28例,男性19例。手术时平均年龄64±8岁,术后平均随访45.4±7.0个月,最短18.9个月。术后双眼未矫正距离视力(UDVA)平均为0.07 logMar (Snellen 20/24), 65 cm处未矫正双眼中间视力为0.07 logMar (20/24), 40 cm处未矫正双眼近视力为0.06 logMar(20/23)。在有眩光和无眩光条件下,对比灵敏度保持在正常的上限。98%的患者满意或非常满意。87%的人不需要戴眼镜进行任何活动,无论是远视还是近视。结论:ReSTOR®IOL混合视力白内障手术视力中期满意,实现了眼镜独立性和高满意度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
VISUAL OUTCOMES, CONTRAST SENSITIVITY, AND SATISFACTION WITH MULTIFOCAL INTRAOCULAR LENS BLENDED TECHNIQUE: LATE MID-TERM RESULTS.

Purpose: To describe clinical visual outcomes, spectacle independence, and patient satisfaction after cataract surgery with blending implantation of ReSTOR (Alcon laboratories) multifocal intraocular lenses.

Material and methods: A single-arm, non-randomized prospective study assessed patients undergoing cataract surgery with ReSTOR® +2.50 intraocular lens in the dominant eye and +3.00 add in the fellow eye between January 2015 to January 2020.

Results: In total, 47 patients (94 eyes) were enrolled, 28 women and 19 men. The average age at surgery time was 64 ±8 years, average postoperative follow-up was 45.4 ±7.0 months, with a minimum of 18.9 months. Postoperative binocular uncorrected distance visual acuity (UDVA) was on average 0.07 logMar (Snellen 20/24), uncorrected binocular intermediate visual acuity at 65 cm was 0.07 logMar (20/24), uncorrected binocular near visual acuity at 40 cm was 0.06 logMar (20/23). Contrast sensitivity under photopic and scotopic conditions, with and without glare, remained at the upper limit of normality. 98% of patients were quite satisfied or very satisfied. 87% did not require glasses for any activities, either at distant vision, nor at near vision.

Conclusions: Cataract surgery with ReSTOR® IOL blended vision showed medium-term satisfactory visual results, achieving spectacle independence and a high level of satisfaction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ceska a Slovenska Oftalmologie
Ceska a Slovenska Oftalmologie Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
0
期刊介绍: - Redakce přijímá pouze práce vyhovující po odborné stránce, které jsou na odpovídající profesionální a formální úrovni. - Uveřejněná práce se stává majetkem časopisu, přetisknout její část nebo obrázek lze jen s citací původu. - Rukopis zasílejte v originále a dobře čitelné kopii (je nutná také kopie tabulek, legend, podle možnosti i obrázků). - Listy číslujte v pravém horním rohu a spojujte svorkou, nesešívejte. Přijímáme práce psané na jedné straně kvalitního bílého nelesklého papíru formátu A4 (neprůklepový) na psacím stroji nebo počítači s obvyklými typy.
期刊最新文献
ULTRASOUND EXAMINATION OF THE ORBIT IN PATIENTS WITH THYROIDASSOCIATED ORBITOPATHY - EXAMINATION GUIDE AND RECOMMENDATIONS FOR EVERYDAY PRACTICE. A REVIEW. Diagnostic Importance of OCT Pachymetry in Keratoconus. Improvement of Visual Field Defects after Neuroembolization Treatment of Intracranial Aneurysms. Case Reports. Pars Plana Vitrectomy in the Treatment of Rhegmatogenous Retinal Detachment. Refractive Errors Among Members of the Armed Forces of the Czech Republic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1