HS-GC-FID方法用于定量细胞培养基中的HFA-152a,以及来自一系列物种的血浆和符合监管的验证

IF 1.3 4区 医学 Q4 PHARMACOLOGY & PHARMACY Journal of pharmacological and toxicological methods Pub Date : 2023-07-01 DOI:10.1016/j.vascn.2023.107271
Philip J. Kuehl , Stuart Corr , Jabari Farrar , Jacob D. McDonald , Tim Wermer , Derek Weber , Chet Leach
{"title":"HS-GC-FID方法用于定量细胞培养基中的HFA-152a,以及来自一系列物种的血浆和符合监管的验证","authors":"Philip J. Kuehl ,&nbsp;Stuart Corr ,&nbsp;Jabari Farrar ,&nbsp;Jacob D. McDonald ,&nbsp;Tim Wermer ,&nbsp;Derek Weber ,&nbsp;Chet Leach","doi":"10.1016/j.vascn.2023.107271","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>1,1-Difluoroethane (HFA-152a) is being developed as an alternative propellant in pressurized metered dose inhalers (pMDIs). As a part of the regulatory development pathway, pharmacology, toxicology and clinical studies have been conducted with inhaled HFA-152a. These studies require fit for purpose regulatory compliant (GxP validated) methods for quantification of HFA-152a from blood.</p></div><div><h3>Methods</h3><p>As HFA-152a is a gas at standard temperature and pressure, novel methods were developed to support the analysis across the wide range of species and concentrations required for regulatory filing.</p></div><div><h3>Results</h3><p>The developed methods utilized a headspace auto sampler coupled to a gas chromatograph (GC) with flame ionization detection. Key factors in the successful method included bringing together fit for purpose approaches to the head space vials, volume of matrix (blood), detection range required for species/study objective, handling / transfer of blood into head space vials and the stability/storage required for the analysis of the samples. The species-specific assays were fully validated under regulatory (GLP) conditions for mouse, rat, rabbit, canine and human and non-regulatory (non GLP) validations for guinea pig and cell culture media.</p></div><div><h3>Discussion</h3><p>Overall the novel approach of head space analysis of whole blood allowed for the development and validation of assays used to generate the toxicokinetic data that supported clinical testing of HFA-152a as a new pMDI propellant.</p></div>","PeriodicalId":16767,"journal":{"name":"Journal of pharmacological and toxicological methods","volume":"122 ","pages":"Article 107271"},"PeriodicalIF":1.3000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"HS-GC-FID method for quantification of HFA-152a in cell culture media, and plasma from a range of species and regulatory compliant validations\",\"authors\":\"Philip J. Kuehl ,&nbsp;Stuart Corr ,&nbsp;Jabari Farrar ,&nbsp;Jacob D. McDonald ,&nbsp;Tim Wermer ,&nbsp;Derek Weber ,&nbsp;Chet Leach\",\"doi\":\"10.1016/j.vascn.2023.107271\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>1,1-Difluoroethane (HFA-152a) is being developed as an alternative propellant in pressurized metered dose inhalers (pMDIs). As a part of the regulatory development pathway, pharmacology, toxicology and clinical studies have been conducted with inhaled HFA-152a. These studies require fit for purpose regulatory compliant (GxP validated) methods for quantification of HFA-152a from blood.</p></div><div><h3>Methods</h3><p>As HFA-152a is a gas at standard temperature and pressure, novel methods were developed to support the analysis across the wide range of species and concentrations required for regulatory filing.</p></div><div><h3>Results</h3><p>The developed methods utilized a headspace auto sampler coupled to a gas chromatograph (GC) with flame ionization detection. Key factors in the successful method included bringing together fit for purpose approaches to the head space vials, volume of matrix (blood), detection range required for species/study objective, handling / transfer of blood into head space vials and the stability/storage required for the analysis of the samples. The species-specific assays were fully validated under regulatory (GLP) conditions for mouse, rat, rabbit, canine and human and non-regulatory (non GLP) validations for guinea pig and cell culture media.</p></div><div><h3>Discussion</h3><p>Overall the novel approach of head space analysis of whole blood allowed for the development and validation of assays used to generate the toxicokinetic data that supported clinical testing of HFA-152a as a new pMDI propellant.</p></div>\",\"PeriodicalId\":16767,\"journal\":{\"name\":\"Journal of pharmacological and toxicological methods\",\"volume\":\"122 \",\"pages\":\"Article 107271\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pharmacological and toxicological methods\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1056871923000229\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacological and toxicological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1056871923000229","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

引言1,1-二氟乙烷(HFA-152a)正被开发为加压计量吸入器的替代推进剂。作为调节发展途径的一部分,已经对吸入HFA-152a进行了药理学、毒理学和临床研究。这些研究需要符合目的的监管(GxP验证)方法来定量血液中的HFA-152a。方法由于HFA-152a是一种在标准温度和压力下的气体,因此开发了新的方法来支持监管备案所需的广泛物种和浓度的分析。结果所开发的方法利用顶空自动采样器与气相色谱(GC)相结合,进行火焰离子化检测。成功方法的关键因素包括将适用于头部空间小瓶的方法、基质(血液)的体积、物种/研究目标所需的检测范围、将血液处理/转移到头部空间小瓶以及分析样本所需的稳定性/储存。物种特异性测定在小鼠、大鼠、兔、犬和人的调节(GLP)条件下以及豚鼠和细胞培养基的非调节(非GLP)验证下得到了充分验证。讨论总体而言,全血头部空间分析的新方法允许开发和验证用于生成毒代动力学数据的分析方法,这些数据支持HFA-152a作为一种新型pMDI推进剂的临床测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
HS-GC-FID method for quantification of HFA-152a in cell culture media, and plasma from a range of species and regulatory compliant validations

Introduction

1,1-Difluoroethane (HFA-152a) is being developed as an alternative propellant in pressurized metered dose inhalers (pMDIs). As a part of the regulatory development pathway, pharmacology, toxicology and clinical studies have been conducted with inhaled HFA-152a. These studies require fit for purpose regulatory compliant (GxP validated) methods for quantification of HFA-152a from blood.

Methods

As HFA-152a is a gas at standard temperature and pressure, novel methods were developed to support the analysis across the wide range of species and concentrations required for regulatory filing.

Results

The developed methods utilized a headspace auto sampler coupled to a gas chromatograph (GC) with flame ionization detection. Key factors in the successful method included bringing together fit for purpose approaches to the head space vials, volume of matrix (blood), detection range required for species/study objective, handling / transfer of blood into head space vials and the stability/storage required for the analysis of the samples. The species-specific assays were fully validated under regulatory (GLP) conditions for mouse, rat, rabbit, canine and human and non-regulatory (non GLP) validations for guinea pig and cell culture media.

Discussion

Overall the novel approach of head space analysis of whole blood allowed for the development and validation of assays used to generate the toxicokinetic data that supported clinical testing of HFA-152a as a new pMDI propellant.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of pharmacological and toxicological methods
Journal of pharmacological and toxicological methods PHARMACOLOGY & PHARMACY-TOXICOLOGY
CiteScore
3.60
自引率
10.50%
发文量
56
审稿时长
26 days
期刊介绍: Journal of Pharmacological and Toxicological Methods publishes original articles on current methods of investigation used in pharmacology and toxicology. Pharmacology and toxicology are defined in the broadest sense, referring to actions of drugs and chemicals on all living systems. With its international editorial board and noted contributors, Journal of Pharmacological and Toxicological Methods is the leading journal devoted exclusively to experimental procedures used by pharmacologists and toxicologists.
期刊最新文献
Molecular imaging of excitability difference between alkaloids/salts (nicotine, nicotinic benzoate, caffeine and arecoline hydrobromide) In-situ polyherbal gel as biomedicine in the management of Alzheimer's disease: Understanding ameliorative potential in Trimethyltin induced neurodegeneration Evaluation of 4 quantification methods for monitoring 16 antidepressant drugs and their metabolites in human plasma by LC-MS/MS Comparative toxicity assessment of selected nanoparticles using different experimental model organisms Evaluating the proarrhythmic risk of delayed-action compounds in serum free cell culture conditions; serum-starvation accelerates/amplifies the effect of probucol on the KCNQ1 + KCNE1 channel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1