Bas Van Hooren, Bart C. Bongers, Bruce Rogers, Thomas Gronwald
{"title":"跑步过程中心率变异性相关特性的日间可靠性。","authors":"Bas Van Hooren, Bart C. Bongers, Bruce Rogers, Thomas Gronwald","doi":"10.1007/s10484-023-09599-x","DOIUrl":null,"url":null,"abstract":"<div><p>The short-term scaling exponent of detrended fluctuation analysis (DFA-a1) of heart rate variability may be a helpful tool to assess autonomic balance as a prelude to daily, individualized training. For this concept to be useful, between-session reliability should be acceptable. The aim of this study was to explore the reliability of DFA-a1 during a low-intensity exercise session in both a non-fatigued and a fatigued condition in healthy males and females. Ten participants completed two sessions with each containing an exhaustive treadmill ramp protocol. Before and after the fatiguing ramp, a standardized submaximal low-intensity exercise bout was performed during which DFA-a1, heart rate, and oxygen consumption (VO<sub>2</sub>) were measured. We compared between-session reliability of all metrics prior to the ramps (i.e., non-fatigued status) and after the first ramp (i.e., fatigued status). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI), the standard error of measurement, and the smallest worthwhile change (SWC) were determined. The ICC and SWC pre fatiguing ramp were 0.85 (95% CI 0.39–0.96) and 5.5% for DFA-a1, 0.85 (0.38–0.96) and 2.2% for heart rate, and 0.84 (0.31–0.96) and 3.1% for VO<sub>2</sub>. Post fatiguing ramp, the ICC and SWC were 0.55 (0.00–0.89) and 7.9% for DFA-a1, 0.91 (0.62–0.98) and 1.6% for heart rate, and 0.80 (0.17–0.95) and 3.0% for VO<sub>2</sub>. DFA-a1 shows generally acceptable to good between-session reliability with a SWC of 0.06 and 0.07 (5.5–7.9%) during non-fatigued and fatigued conditions. This suggests that this metric may be useful to inform on training readiness.\n</p></div>","PeriodicalId":47506,"journal":{"name":"Applied Psychophysiology and Biofeedback","volume":"48 4","pages":"453 - 460"},"PeriodicalIF":2.2000,"publicationDate":"2023-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10484-023-09599-x.pdf","citationCount":"0","resultStr":"{\"title\":\"The Between-Day Reliability of Correlation Properties of Heart Rate Variability During Running\",\"authors\":\"Bas Van Hooren, Bart C. Bongers, Bruce Rogers, Thomas Gronwald\",\"doi\":\"10.1007/s10484-023-09599-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The short-term scaling exponent of detrended fluctuation analysis (DFA-a1) of heart rate variability may be a helpful tool to assess autonomic balance as a prelude to daily, individualized training. For this concept to be useful, between-session reliability should be acceptable. The aim of this study was to explore the reliability of DFA-a1 during a low-intensity exercise session in both a non-fatigued and a fatigued condition in healthy males and females. Ten participants completed two sessions with each containing an exhaustive treadmill ramp protocol. Before and after the fatiguing ramp, a standardized submaximal low-intensity exercise bout was performed during which DFA-a1, heart rate, and oxygen consumption (VO<sub>2</sub>) were measured. We compared between-session reliability of all metrics prior to the ramps (i.e., non-fatigued status) and after the first ramp (i.e., fatigued status). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI), the standard error of measurement, and the smallest worthwhile change (SWC) were determined. The ICC and SWC pre fatiguing ramp were 0.85 (95% CI 0.39–0.96) and 5.5% for DFA-a1, 0.85 (0.38–0.96) and 2.2% for heart rate, and 0.84 (0.31–0.96) and 3.1% for VO<sub>2</sub>. Post fatiguing ramp, the ICC and SWC were 0.55 (0.00–0.89) and 7.9% for DFA-a1, 0.91 (0.62–0.98) and 1.6% for heart rate, and 0.80 (0.17–0.95) and 3.0% for VO<sub>2</sub>. DFA-a1 shows generally acceptable to good between-session reliability with a SWC of 0.06 and 0.07 (5.5–7.9%) during non-fatigued and fatigued conditions. This suggests that this metric may be useful to inform on training readiness.\\n</p></div>\",\"PeriodicalId\":47506,\"journal\":{\"name\":\"Applied Psychophysiology and Biofeedback\",\"volume\":\"48 4\",\"pages\":\"453 - 460\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2023-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s10484-023-09599-x.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Psychophysiology and Biofeedback\",\"FirstCategoryId\":\"102\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10484-023-09599-x\",\"RegionNum\":3,\"RegionCategory\":\"心理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PSYCHOLOGY, CLINICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Psychophysiology and Biofeedback","FirstCategoryId":"102","ListUrlMain":"https://link.springer.com/article/10.1007/s10484-023-09599-x","RegionNum":3,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PSYCHOLOGY, CLINICAL","Score":null,"Total":0}
The Between-Day Reliability of Correlation Properties of Heart Rate Variability During Running
The short-term scaling exponent of detrended fluctuation analysis (DFA-a1) of heart rate variability may be a helpful tool to assess autonomic balance as a prelude to daily, individualized training. For this concept to be useful, between-session reliability should be acceptable. The aim of this study was to explore the reliability of DFA-a1 during a low-intensity exercise session in both a non-fatigued and a fatigued condition in healthy males and females. Ten participants completed two sessions with each containing an exhaustive treadmill ramp protocol. Before and after the fatiguing ramp, a standardized submaximal low-intensity exercise bout was performed during which DFA-a1, heart rate, and oxygen consumption (VO2) were measured. We compared between-session reliability of all metrics prior to the ramps (i.e., non-fatigued status) and after the first ramp (i.e., fatigued status). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI), the standard error of measurement, and the smallest worthwhile change (SWC) were determined. The ICC and SWC pre fatiguing ramp were 0.85 (95% CI 0.39–0.96) and 5.5% for DFA-a1, 0.85 (0.38–0.96) and 2.2% for heart rate, and 0.84 (0.31–0.96) and 3.1% for VO2. Post fatiguing ramp, the ICC and SWC were 0.55 (0.00–0.89) and 7.9% for DFA-a1, 0.91 (0.62–0.98) and 1.6% for heart rate, and 0.80 (0.17–0.95) and 3.0% for VO2. DFA-a1 shows generally acceptable to good between-session reliability with a SWC of 0.06 and 0.07 (5.5–7.9%) during non-fatigued and fatigued conditions. This suggests that this metric may be useful to inform on training readiness.
期刊介绍:
Applied Psychophysiology and Biofeedback is an international, interdisciplinary journal devoted to study of the interrelationship of physiological systems, cognition, social and environmental parameters, and health. Priority is given to original research, basic and applied, which contributes to the theory, practice, and evaluation of applied psychophysiology and biofeedback. Submissions are also welcomed for consideration in several additional sections that appear in the journal. They consist of conceptual and theoretical articles; evaluative reviews; the Clinical Forum, which includes separate categories for innovative case studies, clinical replication series, extended treatment protocols, and clinical notes and observations; the Discussion Forum, which includes a series of papers centered around a topic of importance to the field; Innovations in Instrumentation; Letters to the Editor, commenting on issues raised in articles previously published in the journal; and select book reviews. Applied Psychophysiology and Biofeedback is the official publication of the Association for Applied Psychophysiology and Biofeedback.