血块对从 PAXgene 血液 RNA 管中提取的 RNA 质量的影响。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-04-01 Epub Date: 2023-08-03 DOI:10.1089/bio.2023.0001
Rong Tang, Ling Zhu, Ping Zhu, Ru Yin, Chunxia Zheng
{"title":"血块对从 PAXgene 血液 RNA 管中提取的 RNA 质量的影响。","authors":"Rong Tang, Ling Zhu, Ping Zhu, Ru Yin, Chunxia Zheng","doi":"10.1089/bio.2023.0001","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> PAXgene<sup>®</sup> Blood RNA tubes are routinely used in clinical research and molecular biology applications to preserve the stability of RNA in whole blood. However, in practice, blood clots are occasionally observed after blood collection and are often ignored. Currently, there are few studies on whether blood clots affect the quality of RNA extracted from these tubes. <b><i>Materials and Methods:</i></b> Fifteen pairs of non-clot and clot PAXgene Blood RNA tube samples (<i>n</i> = 30) were collected to form two matched groups from 15 patients. According to the maximum diameter (<i>d</i>) of the blood clot observed visually at the time of sample reception, the clot groups were divided into a small-clot group (0 cm < <i>d</i> < 0.5 cm) and a large-clot group (<i>d</i> ≥ 0.5 cm). RNA was extracted by the PAXgene Blood RNA Kit. To analyze the quality of RNA, its yield and purity were assessed by spectrophotometry, and integrity was measured by microfluidic electrophoresis. An A<sub>260/280</sub> ratio between 1.8 and 2.2 indicated purified RNA, and RNA integrity number (RIN) values ≥7.0 were considered to represent qualified integrity. <b><i>Results:</i></b> The median yields of RNA from the non-clot and clot groups were 3.84 (2.80-6.38) μg and 4.87 (2.77-8.30) μg, respectively. The median A<sub>260/280</sub> ratios were 2.08 (2.06-2.09) and 2.09 (2.07-2.11), whereas the median A<sub>260/230</sub> ratios were 1.77 (1.31-1.91) and 1.67 (1.21-1.94) in the two groups. In addition, the median RINs were 8.20 (8.00-8.40) and 7.20 (6.60-7.70), respectively. There were no significant differences in RNA yields, A<sub>260/280</sub>, or A<sub>260/230</sub> between the two groups. However, the RIN value of the clot group was significantly lower compared with the non-clot group (<i>p</i> < 0.05), with RIN ≥7.0 found in all non-clot samples and 60% of clot samples (<i>p</i> < 0.05). Furthermore, in the clot groups, the small-clot samples had higher RIN values than large-clot samples (8.25 [7.75-8.75] vs. 6.90 [6.60-7.30], <i>p</i> < 0.001). <b><i>Conclusions:</i></b> The formation of large blood clots in PAXgene Blood RNA tubes will reduce the integrity of extracted RNA.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Blood Clots on the Quality of RNA Extracted from PAXgene Blood RNA Tubes.\",\"authors\":\"Rong Tang, Ling Zhu, Ping Zhu, Ru Yin, Chunxia Zheng\",\"doi\":\"10.1089/bio.2023.0001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Background:</i></b> PAXgene<sup>®</sup> Blood RNA tubes are routinely used in clinical research and molecular biology applications to preserve the stability of RNA in whole blood. However, in practice, blood clots are occasionally observed after blood collection and are often ignored. Currently, there are few studies on whether blood clots affect the quality of RNA extracted from these tubes. <b><i>Materials and Methods:</i></b> Fifteen pairs of non-clot and clot PAXgene Blood RNA tube samples (<i>n</i> = 30) were collected to form two matched groups from 15 patients. According to the maximum diameter (<i>d</i>) of the blood clot observed visually at the time of sample reception, the clot groups were divided into a small-clot group (0 cm < <i>d</i> < 0.5 cm) and a large-clot group (<i>d</i> ≥ 0.5 cm). RNA was extracted by the PAXgene Blood RNA Kit. To analyze the quality of RNA, its yield and purity were assessed by spectrophotometry, and integrity was measured by microfluidic electrophoresis. An A<sub>260/280</sub> ratio between 1.8 and 2.2 indicated purified RNA, and RNA integrity number (RIN) values ≥7.0 were considered to represent qualified integrity. <b><i>Results:</i></b> The median yields of RNA from the non-clot and clot groups were 3.84 (2.80-6.38) μg and 4.87 (2.77-8.30) μg, respectively. The median A<sub>260/280</sub> ratios were 2.08 (2.06-2.09) and 2.09 (2.07-2.11), whereas the median A<sub>260/230</sub> ratios were 1.77 (1.31-1.91) and 1.67 (1.21-1.94) in the two groups. In addition, the median RINs were 8.20 (8.00-8.40) and 7.20 (6.60-7.70), respectively. There were no significant differences in RNA yields, A<sub>260/280</sub>, or A<sub>260/230</sub> between the two groups. However, the RIN value of the clot group was significantly lower compared with the non-clot group (<i>p</i> < 0.05), with RIN ≥7.0 found in all non-clot samples and 60% of clot samples (<i>p</i> < 0.05). Furthermore, in the clot groups, the small-clot samples had higher RIN values than large-clot samples (8.25 [7.75-8.75] vs. 6.90 [6.60-7.30], <i>p</i> < 0.001). <b><i>Conclusions:</i></b> The formation of large blood clots in PAXgene Blood RNA tubes will reduce the integrity of extracted RNA.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1089/bio.2023.0001\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1089/bio.2023.0001","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

背景:PAXgene® 血液 RNA 管通常用于临床研究和分子生物学应用,以保持全血中 RNA 的稳定性。然而,在实践中,采血后偶尔会观察到血凝块,但往往被忽视。目前,有关血凝块是否会影响从这些试管中提取的 RNA 质量的研究很少。材料与方法:从 15 名患者中收集 15 对无血块和有血块的 PAXgene 血液 RNA 管样本(n = 30),形成两个匹配组。根据接收样本时肉眼观察到的血凝块最大直径(d),将血凝块组分为小血凝块组(0 cm < d d ≥ 0.5 cm)。用 PAXgene 血液 RNA 试剂盒提取 RNA。为了分析 RNA 的质量,用分光光度法评估其产量和纯度,并用微流控电泳法测定其完整性。A260/280 比率在 1.8 和 2.2 之间表示 RNA 已纯化,RNA 完整性编号(RIN)值≥7.0 则表示 RNA 完整性合格。结果非血块组和血块组的 RNA 产量中位数分别为 3.84 (2.80-6.38) μg 和 4.87 (2.77-8.30) μg。两组的 A260/280 比率中位数分别为 2.08(2.06-2.09)和 2.09(2.07-2.11),而 A260/230 比率中位数分别为 1.77(1.31-1.91)和 1.67(1.21-1.94)。此外,RIN 中位数分别为 8.20(8.00-8.40)和 7.20(6.60-7.70)。两组的 RNA 产量、A260/280 或 A260/230 均无明显差异。然而,与无血块组相比,血块组的 RIN 值明显较低(P P P 结论):PAXgene 血液 RNA 管中大块血凝块的形成会降低提取 RNA 的完整性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Effect of Blood Clots on the Quality of RNA Extracted from PAXgene Blood RNA Tubes.

Background: PAXgene® Blood RNA tubes are routinely used in clinical research and molecular biology applications to preserve the stability of RNA in whole blood. However, in practice, blood clots are occasionally observed after blood collection and are often ignored. Currently, there are few studies on whether blood clots affect the quality of RNA extracted from these tubes. Materials and Methods: Fifteen pairs of non-clot and clot PAXgene Blood RNA tube samples (n = 30) were collected to form two matched groups from 15 patients. According to the maximum diameter (d) of the blood clot observed visually at the time of sample reception, the clot groups were divided into a small-clot group (0 cm < d < 0.5 cm) and a large-clot group (d ≥ 0.5 cm). RNA was extracted by the PAXgene Blood RNA Kit. To analyze the quality of RNA, its yield and purity were assessed by spectrophotometry, and integrity was measured by microfluidic electrophoresis. An A260/280 ratio between 1.8 and 2.2 indicated purified RNA, and RNA integrity number (RIN) values ≥7.0 were considered to represent qualified integrity. Results: The median yields of RNA from the non-clot and clot groups were 3.84 (2.80-6.38) μg and 4.87 (2.77-8.30) μg, respectively. The median A260/280 ratios were 2.08 (2.06-2.09) and 2.09 (2.07-2.11), whereas the median A260/230 ratios were 1.77 (1.31-1.91) and 1.67 (1.21-1.94) in the two groups. In addition, the median RINs were 8.20 (8.00-8.40) and 7.20 (6.60-7.70), respectively. There were no significant differences in RNA yields, A260/280, or A260/230 between the two groups. However, the RIN value of the clot group was significantly lower compared with the non-clot group (p < 0.05), with RIN ≥7.0 found in all non-clot samples and 60% of clot samples (p < 0.05). Furthermore, in the clot groups, the small-clot samples had higher RIN values than large-clot samples (8.25 [7.75-8.75] vs. 6.90 [6.60-7.30], p < 0.001). Conclusions: The formation of large blood clots in PAXgene Blood RNA tubes will reduce the integrity of extracted RNA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Management of Cholesteatoma: Hearing Rehabilitation. Congenital Cholesteatoma. Evaluation of Cholesteatoma. Management of Cholesteatoma: Extension Beyond Middle Ear/Mastoid. Recidivism and Recurrence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1