Investigation of the effect of different surface treatments for preventing detachment of polyetheretherketone and titanium attachment matrix housings in overdentures: An in vitro study.

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE The Journal of Indian Prosthodontic Society Pub Date : 2023-04-01 DOI:10.4103/jips.jips_497_22
Pınar Yıldız, Damla Güneş Ünlü
{"title":"Investigation of the effect of different surface treatments for preventing detachment of polyetheretherketone and titanium attachment matrix housings in overdentures: An <i>in vitro</i> study.","authors":"Pınar Yıldız, Damla Güneş Ünlü","doi":"10.4103/jips.jips_497_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The attachment matrix housing (AMH) of implant overdentures is not chemically bonded with acrylic resins. Therefore, AMH may lose due to insertion and removal forces. This study aims to investigate the effects of different surface treatments to reduce the detachment of AMH and to compare the adhesion of the AMH used in implant-supported overdentures made of different materials with the reline acrylic resin.</p><p><strong>Materials and methods: </strong>Titanium and polyetheretherketone (PEEK) AMHs were separated into four surface treatment groups; no treatment, airborne-particle abrasion (APA) applied, universal bond (UB) applicated, APA, and UB applicated. Eight millimeters in diameter and ten millimeters tall straws were used to restrain the reline acrylic resin prepared according to the manufacturer's instructions and the resin was injected onto the surface-treated AMH. After the polymerization was completed, the universal testing machine performed the tensile bond strength (TBS) test with a fishing line passed through the acrylic resins.</p><p><strong>Statistical analysis used: </strong>TBS data were analyzed with two and one-way ANOVA and Tukey HSD post hoc tests (α =0.05).</p><p><strong>Results: </strong>According to the two-way ANOVA results, titanium AMHs (103.78 ± 45.98 N) showed higher TBS than PEEK AMHs (67.81 ± 28.61 N). UB applicated titanium groups showed significantly increased TBS values.</p><p><strong>Conclusions: </strong>Using titanium AMHs may be a better choice in situations where clinical aesthetic expectations are unimportant for adhesion to reline acrylic resins. The UB resin significantly increased the bonding of the titanium AMHs with reline resins. The application of UB resin to titanium housings can be easily applied in a clinical situation and can reduce the detachment of the titanium AMHs.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"23 2","pages":"142-149"},"PeriodicalIF":1.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10262101/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_497_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The attachment matrix housing (AMH) of implant overdentures is not chemically bonded with acrylic resins. Therefore, AMH may lose due to insertion and removal forces. This study aims to investigate the effects of different surface treatments to reduce the detachment of AMH and to compare the adhesion of the AMH used in implant-supported overdentures made of different materials with the reline acrylic resin.

Materials and methods: Titanium and polyetheretherketone (PEEK) AMHs were separated into four surface treatment groups; no treatment, airborne-particle abrasion (APA) applied, universal bond (UB) applicated, APA, and UB applicated. Eight millimeters in diameter and ten millimeters tall straws were used to restrain the reline acrylic resin prepared according to the manufacturer's instructions and the resin was injected onto the surface-treated AMH. After the polymerization was completed, the universal testing machine performed the tensile bond strength (TBS) test with a fishing line passed through the acrylic resins.

Statistical analysis used: TBS data were analyzed with two and one-way ANOVA and Tukey HSD post hoc tests (α =0.05).

Results: According to the two-way ANOVA results, titanium AMHs (103.78 ± 45.98 N) showed higher TBS than PEEK AMHs (67.81 ± 28.61 N). UB applicated titanium groups showed significantly increased TBS values.

Conclusions: Using titanium AMHs may be a better choice in situations where clinical aesthetic expectations are unimportant for adhesion to reline acrylic resins. The UB resin significantly increased the bonding of the titanium AMHs with reline resins. The application of UB resin to titanium housings can be easily applied in a clinical situation and can reduce the detachment of the titanium AMHs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同表面处理方法对防止聚醚醚酮和钛附件基质外壳脱落的影响:体外研究。
目的:种植体覆盖义齿的连接基质外壳(AMH)与丙烯酸树脂没有化学粘结。因此,AMH 可能会因插入和拔出力而脱落。本研究旨在探讨不同的表面处理方法对减少AMH脱落的影响,并比较不同材料制成的种植体支撑覆盖义齿中使用的AMH与再衬丙烯酸树脂的粘附性:将钛和聚醚醚酮(PEEK)AMH分为四个表面处理组:无处理组、气载颗粒磨蚀(APA)应用组、通用粘结(UB)应用组、APA应用组和UB应用组。用直径八毫米、高十毫米的吸管吸住按照制造商说明制备的再衬垫丙烯酸树脂,然后将树脂注射到表面处理过的 AMH 上。聚合完成后,万能试验机用鱼线穿过丙烯酸树脂进行拉伸粘接强度(TBS)测试:采用双因素方差分析和单因素方差分析对 TBS 数据进行分析,并进行 Tukey HSD 后检验(α =0.05):根据双向方差分析结果,钛 AMHs(103.78 ± 45.98 N)的 TBS 值高于 PEEK AMHs(67.81 ± 28.61 N)。结论:结论:在临床美学期望值对粘附再衬丙烯酸树脂不重要的情况下,使用钛AMH可能是更好的选择。UB 树脂明显提高了钛 AMH 与再衬丙烯酸树脂的粘接性。在钛外壳上使用 UB 树脂可以很容易地应用于临床,并且可以减少钛 AMH 的脱落。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
期刊最新文献
A comparative evaluation of marginal fit and microleakage of computer-aided design/computer-aided manufacturing-milled zirconia and prefabricated posterior occlusal veneers: An in vitrostudy. An evaluation of antagonist enamel wear opposing full-coverage zirconia crowns versus other ceramics full-coverage crowns and natural enamel - An umbrella review. Evaluation of flexural strength and microhardness in Vaccinium macrocarpon (cranberry)-added self-cure polymethyl methacrylate dental resin: An in vitro study. Knowledge and awareness about temporomandibular disorder among dentists in India: Questionnaire study and review. Precise jaw relation recorder: An innovative device for prosthodontic rehabilitation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1