{"title":"Feasibility analysis of digital method for measuring supracrestal tissue height crest around implant.","authors":"Luxin Li, Honghong Liu, Jia Chen, Zhihong Zhang, Xiao Sang, Lili Zhang, Yuantian Wang","doi":"10.7518/hxkq.2023.2023089","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to investigate the feasibility of measuring the soft tissue height of bone cristae around implant by digital method.</p><p><strong>Methods: </strong>A total of 36 patients with dental implants were selected from the Dental Medicine Center of the First Affiliated Hospital of University of Science and Technology of China (Anhui Provincial Hospital) from August 2022 to December 2022. A total of 43 dental implants were enrolled. All postoperative cone beam CT (CBCT) imaging data and intraoral digital impressions obtained before surgery were immediately obtained by the patients on the day of completion of oral implant surgery and they were imported into oral implant surgery planning software for image fitting. Then, virtual implants of the same specification were placed in the planting area, and the implant position was adjusted to overlap with the implant shadow in the CBCT image. Supracrestal tissue height (STH) was measured at the implant view interface (digital group). During the operation, implant holes were prepared step by step in accordance with the standard preparation method, and implants were implanted. The upper edge of the implant was flushed with the crest of the alveolar ridge. STH was measured by perio-dontal probing (periodontal probe group). Paired <i>t</i>-test was used to compare the STH differences between the digital and periodontal probe groups. Bland-Altman test was used to analyze the consistency of the two methods. Intra-group correlation coefficient (ICC) was used to verify the reliability of the results measured by different surveyors using di-gital methods.</p><p><strong>Results: </strong>No statistical significance was observed in the STH difference between the two methods (<i>P</i>>0.05). Bland-Altman test showed good consistency between the two methods, but the measurement of mandibular posterior teeth showed that the results of periodontal probe were greater than those of digital method. The ICC and 95%CI of the STH results measured digitally by different surveyors are 0.992 (0.986-0.996).</p><p><strong>Conclusions: </strong>The digital me-thod is in good agreement with the periodontal probe method in measuring the soft tissue height of the bone cristae around the implant.</p>","PeriodicalId":35800,"journal":{"name":"华西口腔医学杂志","volume":"41 4","pages":"426-433"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10372536/pdf/wcjs-41-04-426.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"华西口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7518/hxkq.2023.2023089","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: This study aimed to investigate the feasibility of measuring the soft tissue height of bone cristae around implant by digital method.
Methods: A total of 36 patients with dental implants were selected from the Dental Medicine Center of the First Affiliated Hospital of University of Science and Technology of China (Anhui Provincial Hospital) from August 2022 to December 2022. A total of 43 dental implants were enrolled. All postoperative cone beam CT (CBCT) imaging data and intraoral digital impressions obtained before surgery were immediately obtained by the patients on the day of completion of oral implant surgery and they were imported into oral implant surgery planning software for image fitting. Then, virtual implants of the same specification were placed in the planting area, and the implant position was adjusted to overlap with the implant shadow in the CBCT image. Supracrestal tissue height (STH) was measured at the implant view interface (digital group). During the operation, implant holes were prepared step by step in accordance with the standard preparation method, and implants were implanted. The upper edge of the implant was flushed with the crest of the alveolar ridge. STH was measured by perio-dontal probing (periodontal probe group). Paired t-test was used to compare the STH differences between the digital and periodontal probe groups. Bland-Altman test was used to analyze the consistency of the two methods. Intra-group correlation coefficient (ICC) was used to verify the reliability of the results measured by different surveyors using di-gital methods.
Results: No statistical significance was observed in the STH difference between the two methods (P>0.05). Bland-Altman test showed good consistency between the two methods, but the measurement of mandibular posterior teeth showed that the results of periodontal probe were greater than those of digital method. The ICC and 95%CI of the STH results measured digitally by different surveyors are 0.992 (0.986-0.996).
Conclusions: The digital me-thod is in good agreement with the periodontal probe method in measuring the soft tissue height of the bone cristae around the implant.
期刊介绍:
West China Journal of Stomatology (WCJS, pISSN 1000-1182, eISSN 2618-0456, CN 51-1169/R), published bimonthly, is a peer-reviewed Open Access journal, hosted by Sichuan university and Ministry of Education of the People's Republic of China. WCJS was established in 1983 and indexed in Medline/Pubmed, SCOPUS, EBSCO, Chemical Abstract(CA), CNKI, WANFANG Data, etc.