Revision of total knee arthroplasty with press-fit condylar SIGMA TC3-mobile bearing system and porous metaphyseal sleeves in type AORI type II and III bone defects. A long-term follow-up study.
{"title":"Revision of total knee arthroplasty with press-fit condylar SIGMA TC3-mobile bearing system and porous metaphyseal sleeves in type AORI type II and III bone defects. A long-term follow-up study.","authors":"Fabio Zanchini, Davide Piscopo, Enrico Pola, Valerio Cipolloni, Antonio Piscopo, Stefano Cacciapuoti, Gabriele Colò, Federico Fusini","doi":"10.23750/abm.v94i4.13117","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aim: </strong>Revision total knee arthroplasty(rTKA) is a challenging and expensive treatment for orthopedic surgeons who have to deal with poor bone quality and bone loss. This study aims to retrospectively evaluate the clinical and radiological results of patients undergoing rTKA and porous metaphyseal sleeves in AORI type II and III bone defects.</p><p><strong>Methods: </strong>We conducted a retrospective series of continuous patients treated for mechanical failure of TKA. All patients with aseptic loosening of TKR underwent revision arthroplasty. We included only patients with AORI type IIa/b and III bone defects. The Septic revision or other grades of bone defect or patients lost at follow-up or with less than 2 years follow-up were excluded. We evaluated knee function with Oxford Knee Score (OKS) pain with Visual Analogue Scale (VAS) and range of motion (flex-ext), while radiological evaluation was performed to evaluate any sign of loosening.</p><p><strong>Results: </strong>The mean preoperative OKS was 13.85 +/- 5.39 (range 5 -22), and it improved to 33.89 +/- 3.98 (range 20 - 40) (p<0.00001). The mean preoperative VAS was 7.77 +/- 1.33 (range 5 - 9), and it improved to 1.89 +/- 0.92 (range 0 - 4) (p<0.00001). ROM improved from 62.23° +/- 13.71° (range 40° - 90°) to 100.53° +/- 6.93° (range 90° - 120°) (p<0.00001). No signs of loosening or implant migration were reported.</p><p><strong>Conclusions: </strong>Metaphyseal sleeves made knee revision in large bone defects reliable and effective with good results. Good implant stability was reached in all the cases treated with metaphyseal sleeves.</p>","PeriodicalId":35682,"journal":{"name":"Acta Biomedica de l''Ateneo Parmense","volume":"94 4","pages":"e2023183"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/53/12/ACTA-94-183.PMC10440776.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Biomedica de l''Ateneo Parmense","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23750/abm.v94i4.13117","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background and aim: Revision total knee arthroplasty(rTKA) is a challenging and expensive treatment for orthopedic surgeons who have to deal with poor bone quality and bone loss. This study aims to retrospectively evaluate the clinical and radiological results of patients undergoing rTKA and porous metaphyseal sleeves in AORI type II and III bone defects.
Methods: We conducted a retrospective series of continuous patients treated for mechanical failure of TKA. All patients with aseptic loosening of TKR underwent revision arthroplasty. We included only patients with AORI type IIa/b and III bone defects. The Septic revision or other grades of bone defect or patients lost at follow-up or with less than 2 years follow-up were excluded. We evaluated knee function with Oxford Knee Score (OKS) pain with Visual Analogue Scale (VAS) and range of motion (flex-ext), while radiological evaluation was performed to evaluate any sign of loosening.
Results: The mean preoperative OKS was 13.85 +/- 5.39 (range 5 -22), and it improved to 33.89 +/- 3.98 (range 20 - 40) (p<0.00001). The mean preoperative VAS was 7.77 +/- 1.33 (range 5 - 9), and it improved to 1.89 +/- 0.92 (range 0 - 4) (p<0.00001). ROM improved from 62.23° +/- 13.71° (range 40° - 90°) to 100.53° +/- 6.93° (range 90° - 120°) (p<0.00001). No signs of loosening or implant migration were reported.
Conclusions: Metaphyseal sleeves made knee revision in large bone defects reliable and effective with good results. Good implant stability was reached in all the cases treated with metaphyseal sleeves.
期刊介绍:
Acta Bio Medica Atenei Parmensis is the official Journal of the Society of Medicine and Natural Sciences of Parma, and it is one of the few Italian Journals to be included in many excellent scientific data banks (i.e. MEDLINE). Acta Bio Medica was founded in 1887 and its founders and collaborators, Clinicians and Surgeons, entered history. Acta Bio Medica Atenei Parmensis publishes Original Articles, Commentaries, Review Articles, Case Reports of experimental and general Medicine. A section is devoted to a Continuous Medical Education programme in order to help primary care Physicians to improve the quality of care.