Measurement Repeatability and Reproducibility of Virtual Goniometry of a Set of Acquired Images in Youths with Arthrogryposis Multiplex Congenita.

IF 1.7 4区 医学 Q4 NEUROSCIENCES Journal of musculoskeletal & neuronal interactions Pub Date : 2023-06-01
Marianne Gagnon, Gabriela Marino Merlo, Noémi Dahan-Oliel, Louis-Nicolas Veilleux
{"title":"Measurement Repeatability and Reproducibility of Virtual Goniometry of a Set of Acquired Images in Youths with Arthrogryposis Multiplex Congenita.","authors":"Marianne Gagnon,&nbsp;Gabriela Marino Merlo,&nbsp;Noémi Dahan-Oliel,&nbsp;Louis-Nicolas Veilleux","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the intra-rater repeatability and the inter-rater reproducibility of using a virtual goniometer to measure upper and lower extremity joint range of motion (ROM) in youths with arthrogryposis multiplex congenita (AMC).</p><p><strong>Methods: </strong>Youths presenting with AMC aged 8 to 21 years old were recruited. ROM of the upper and lower limbs were assessed remotely during a teleassessment on a video-conferencing platform. Screen captures were taken and ROM were measured by two raters, two-weeks apart, using a virtual goniometer. Intraclass correlation coefficient (ICC) and associated 95% confidence interval (CI) were calculated to assess intra-and inter-rater repeatability and reproducibility.</p><p><strong>Results: </strong>Nine participants were included with a median age of 15.9 years (range: 11.3 to 20.8 years). The overall intra-rater ICC was 0.997 (95% CI:0.996 to 0.997) for the first rater and 0.993 (95% CI:0.992 to 0.994) for the second rater. The inter-rater ICC ranged from 0.410 (95% CI:-0.392; 0.753) for forearm pronation to 0.998 (95% CI:0.996; 0.999) for elbow flexion.</p><p><strong>Conclusions: </strong>Results of the current study suggest that virtual goniometry is reproducible and repeatable for the ROM of most joints. Future studies should evaluate procedural reliability and validity of the proposed method for youth with complex conditions.</p>","PeriodicalId":16430,"journal":{"name":"Journal of musculoskeletal & neuronal interactions","volume":"23 2","pages":"175-188"},"PeriodicalIF":1.7000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/87/ca/JMNI-23-175.PMC10233227.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of musculoskeletal & neuronal interactions","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the intra-rater repeatability and the inter-rater reproducibility of using a virtual goniometer to measure upper and lower extremity joint range of motion (ROM) in youths with arthrogryposis multiplex congenita (AMC).

Methods: Youths presenting with AMC aged 8 to 21 years old were recruited. ROM of the upper and lower limbs were assessed remotely during a teleassessment on a video-conferencing platform. Screen captures were taken and ROM were measured by two raters, two-weeks apart, using a virtual goniometer. Intraclass correlation coefficient (ICC) and associated 95% confidence interval (CI) were calculated to assess intra-and inter-rater repeatability and reproducibility.

Results: Nine participants were included with a median age of 15.9 years (range: 11.3 to 20.8 years). The overall intra-rater ICC was 0.997 (95% CI:0.996 to 0.997) for the first rater and 0.993 (95% CI:0.992 to 0.994) for the second rater. The inter-rater ICC ranged from 0.410 (95% CI:-0.392; 0.753) for forearm pronation to 0.998 (95% CI:0.996; 0.999) for elbow flexion.

Conclusions: Results of the current study suggest that virtual goniometry is reproducible and repeatable for the ROM of most joints. Future studies should evaluate procedural reliability and validity of the proposed method for youth with complex conditions.

Abstract Image

Abstract Image

Abstract Image

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
青少年多重先天性关节挛缩的一组获得图像的虚拟角度测量的测量重复性和再现性。
目的:评价虚拟测角仪测量青少年多重先天性关节挛缩(AMC)患者上肢和下肢关节活动范围(ROM)的内、间重复性。方法:招募年龄在8 ~ 21岁的出现AMC的青少年。在视频会议平台上进行远程评估时,对上肢和下肢的ROM进行远程评估。屏幕截图和ROM由两名评分者使用虚拟测角仪测量,间隔两周。计算组内相关系数(ICC)和相关95%置信区间(CI)以评估组内和组间的重复性和再现性。结果:纳入9名参与者,中位年龄为15.9岁(范围:11.3至20.8岁)。第一组的总体评分内ICC为0.997 (95% CI:0.996 ~ 0.997),第二组为0.993 (95% CI:0.992 ~ 0.994)。评分间ICC范围为0.410 (95% CI:-0.392;0.753)至0.998 (95% CI:0.996;0.999)肘关节屈曲。结论:目前的研究结果表明,虚拟角度测量法对大多数关节的ROM是可再现和可重复的。未来的研究应评估程序的信度和有效性提出的方法,以青年复杂的条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.40
自引率
0.00%
发文量
67
审稿时长
>12 weeks
期刊介绍: The Journal of Musculoskeletal and Neuronal Interactions (JMNI) is an academic journal dealing with the pathophysiology and treatment of musculoskeletal disorders. It is published quarterly (months of issue March, June, September, December). Its purpose is to publish original, peer-reviewed papers of research and clinical experience in all areas of the musculoskeletal system and its interactions with the nervous system, especially metabolic bone diseases, with particular emphasis on osteoporosis. Additionally, JMNI publishes the Abstracts from the biannual meetings of the International Society of Musculoskeletal and Neuronal Interactions, and hosts Abstracts of other meetings on topics related to the aims and scope of JMNI.
期刊最新文献
A Comparative Study of the Early Postoperative Outcome of Three Intramedullary Fixation Modalities in the Treatment of Intertrochanteric Fractures of the Femur in the Elderly. Analysis of Pathological Factors of Long Head of Biceps Tendinopathy Based on Network Pharmacology. Commentary to: The Diagnostic Role of Adding the Hoffman Reflex for L5 Radiculopathy in the Electrodiagnostic Laboratory: A Cross-sectional Study. Effect of a Rehabilitation Program Including Home-Based Vibration-Assisted Therapy on Gait Parameters in Children with Cerebral Palsy. Effect of Upper Limb Repetitive Facilitative Exercise on Gait of Stroke Patients based on Artificial Intelligence and Computer Vision Evaluation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1