Conduction system pacing in difficult cardiac anatomies: Systematic approach with the 3D electroanatomic mapping guide

Lina Marcantoni, Marco Centioni, Gianni Pastore, Federico Aneris, Enrico Baracca, Francesco Zanon
{"title":"Conduction system pacing in difficult cardiac anatomies: Systematic approach with the 3D electroanatomic mapping guide","authors":"Lina Marcantoni,&nbsp;Marco Centioni,&nbsp;Gianni Pastore,&nbsp;Federico Aneris,&nbsp;Enrico Baracca,&nbsp;Francesco Zanon","doi":"10.1016/j.ipej.2023.08.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Restoring physiological cardiac electrical activity in patients with conduction disease can be crucial for the survival and quality of life. Conduction system pacing (CSP) is a valuable option, although it is limited by technical challenges in difficult anatomies. 3D electroanatomical mapping (3D-EAM) can support CSP ensuring high electro-anatomical precision and low fluoroscopy.</p></div><div><h3>Objectives</h3><p>We evaluated the feasibility and effectiveness of a systematic 3D-EAM use to guide CSP in difficult anatomical scenarios (highly dilated atria, congenital cardiomyopathies, failed biventricular implants (BiV) and pacing-induced cardiomyopathy (PICM)).</p></div><div><h3>Methods</h3><p>Forty-three consecutive patients (27 males, 75 ± 10 years old) with standard pacing indications and difficult anatomical scenarios were included. The right atrium, His cloud, and atrio-ventricular septum were reconstructed by 3D-EAM. The His bundle (HB) was the initial target, while left bundle branch area pacing (LBBAP) was aimed at in case of unsatisfactory parameters, sub-optimally paced QRS, or impossibility of reaching the HB.</p></div><div><h3>Results</h3><p>CSP was successful in 37 (86%) patients (15 HBP; 22 LBBAP). Mean mapping, fluoroscopy, and procedural times were 18 ± 7 min, 7 ± 5 min, 98 ± 47 min, respectively. The mean pacing threshold, R wave sensing, and pacing impedance of CSP lead were 1.2 ± [email protected], 11.4 ± 6.2 mV, 736 ± 306 Ω, respectively. Baseline and paced QRS were 139 ± 38 ms and 114 ± 23 ms, respectively. No procedural complications were observed.</p></div><div><h3>Conclusions</h3><p>3D-EAM allowed the accurate definition of the His cloud and high ventricular septum and effectively guided CSP. It facilitated CSP in complex anatomies, with a procedural success rate of 86%. The results were satisfactory and reproducible, with acceptable fluoroscopy and procedural times.</p></div>","PeriodicalId":35900,"journal":{"name":"Indian Pacing and Electrophysiology Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0972629223000943/pdfft?md5=5a29721e1788895205a15daa84021513&pid=1-s2.0-S0972629223000943-main.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Pacing and Electrophysiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0972629223000943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction

Restoring physiological cardiac electrical activity in patients with conduction disease can be crucial for the survival and quality of life. Conduction system pacing (CSP) is a valuable option, although it is limited by technical challenges in difficult anatomies. 3D electroanatomical mapping (3D-EAM) can support CSP ensuring high electro-anatomical precision and low fluoroscopy.

Objectives

We evaluated the feasibility and effectiveness of a systematic 3D-EAM use to guide CSP in difficult anatomical scenarios (highly dilated atria, congenital cardiomyopathies, failed biventricular implants (BiV) and pacing-induced cardiomyopathy (PICM)).

Methods

Forty-three consecutive patients (27 males, 75 ± 10 years old) with standard pacing indications and difficult anatomical scenarios were included. The right atrium, His cloud, and atrio-ventricular septum were reconstructed by 3D-EAM. The His bundle (HB) was the initial target, while left bundle branch area pacing (LBBAP) was aimed at in case of unsatisfactory parameters, sub-optimally paced QRS, or impossibility of reaching the HB.

Results

CSP was successful in 37 (86%) patients (15 HBP; 22 LBBAP). Mean mapping, fluoroscopy, and procedural times were 18 ± 7 min, 7 ± 5 min, 98 ± 47 min, respectively. The mean pacing threshold, R wave sensing, and pacing impedance of CSP lead were 1.2 ± [email protected], 11.4 ± 6.2 mV, 736 ± 306 Ω, respectively. Baseline and paced QRS were 139 ± 38 ms and 114 ± 23 ms, respectively. No procedural complications were observed.

Conclusions

3D-EAM allowed the accurate definition of the His cloud and high ventricular septum and effectively guided CSP. It facilitated CSP in complex anatomies, with a procedural success rate of 86%. The results were satisfactory and reproducible, with acceptable fluoroscopy and procedural times.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
传导系统起搏在困难的心脏解剖:系统的方法与三维电解剖作图指南。
导读:恢复传导疾病患者的生理性心电活动对患者的生存和生活质量至关重要。传导系统起搏(CSP)是一个有价值的选择,尽管在困难的解剖结构中受到技术挑战的限制。3D电解剖映射(3D- eam)可以支持CSP,确保高电解剖精度和低透视。目的:我们评估了系统3D-EAM在困难解剖情况下(心房高度扩张、先天性心肌病、双心室植入物(BiV)失败和起搏性心肌病(PICM))指导CSP的可行性和有效性。方法:连续43例患者(27例男性,75±10岁),起搏适应证标准,解剖情况困难。3D-EAM重建右心房、His云、房室间隔。肝束(HB)是最初的目标,而左束分支区域起搏(LBBAP)的目标是在参数不理想、次优起搏QRS或无法到达HB的情况下。结果:37例(86%)患者CSP成功(15 HBP;22 LBBAP)。平均作图时间、透视时间和手术时间分别为18±7分钟、7±5分钟、98±47分钟。CSP导联的起搏阈值均值为1.2±0.5V@0.5ms, R波感知均值为11.4±6.2 mV,起搏阻抗均值为736±306 Ω。基线QRS为139±38 ms,节律QRS为114±23 ms。无手术并发症。结论:3D-EAM可以准确定义His云和高室间隔,有效指导CSP。它促进了复杂解剖结构的CSP,手术成功率为86%。结果令人满意,可重复性,可接受的透视和操作时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal Medicine-Cardiology and Cardiovascular Medicine
CiteScore
2.20
自引率
0.00%
发文量
91
审稿时长
61 days
期刊介绍: Indian Pacing and Electrophysiology Journal is a peer reviewed online journal devoted to cardiac pacing and electrophysiology. Editorial Advisory Board includes eminent personalities in the field of cardiac pacing and electrophysiology from Asia, Australia, Europe and North America.
期刊最新文献
Atrial leadless pacemaker implant using Aveir VR in an Adolescent with congenital heart disease. Feasibility of a using chest strap and dry electrode system for longer term cardiac arrhythmia monitoring: Correspondence. Two distinct stages and mechanisms of ST-elevation during cryothermal cavotricuspid isthmus ablation guided by intracardiac echocardiography: A case report. Pivoting turn-around activation guided successful slow pathway ablation in the cavotricuspid isthmus. Late onset of two concurrent and dissociated arrhythmias in a transplanted heart.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1