Prolonged Use of an Automated Insulin Delivery System Improves Sleep in Long-Standing Type 1 Diabetes Complicated by Impaired Awareness of Hypoglycemia.
Susan Kohl Malone, Austin M Matus, Anneliese J Flatt, Amy J Peleckis, Laura Grunin, Gary Yu, Sooyong Jang, James Weimer, Insup Lee, Michael R Rickels, Namni Goel
{"title":"Prolonged Use of an Automated Insulin Delivery System Improves Sleep in Long-Standing Type 1 Diabetes Complicated by Impaired Awareness of Hypoglycemia.","authors":"Susan Kohl Malone, Austin M Matus, Anneliese J Flatt, Amy J Peleckis, Laura Grunin, Gary Yu, Sooyong Jang, James Weimer, Insup Lee, Michael R Rickels, Namni Goel","doi":"10.1177/19322968231182406","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study assessed changes in actigraphy-estimated sleep and glycemic outcomes after initiating automated insulin delivery (AID).</p><p><strong>Methods: </strong>Ten adults with long-standing type 1 diabetes and impaired awareness of hypoglycemia (IAH) participated in an 18-month clinical trial assessing an AID intervention on hypoglycemia and counter-regulatory mechanisms. Data from eight participants (median age = 58 years) with concurrent wrist actigraph and continuous glucose monitoring (CGM) data were used in the present analyses. Actigraphs and CGM measured sleep and glycemic control at baseline (one week) and months 3, 6, 9, 12, 15, and 18 (three weeks) following AID initiation. HypoCount software integrated actigraphy with CGM data to separate wake and sleep-associated glycemic measures. Paired sample <i>t</i>-tests and Cohen's <i>d</i> effect sizes modeled changes and their magnitude in sleep, glycemic control, IAH (Clarke score), hypoglycemia severity (HYPO score), hypoglycemia exposure (CGM), and glycemic variability (lability index [LI]; CGM coefficient-of-variation [CV]) from baseline to 18 months.</p><p><strong>Results: </strong>Sleep improved from baseline to 18 months (shorter sleep latency [<i>P</i> < .05, <i>d</i> = 1.74], later sleep offset [<i>P</i> < .05, <i>d</i> = 0.90], less wake after sleep onset [<i>P</i> < .01, <i>d</i> = 1.43]). Later sleep onset (<i>d</i> = 0.74) and sleep midpoint (<i>d</i> = 0.77) showed medium effect sizes. Sleep improvements were evident from 12 to 15 months after AID initiation and were preceded by improved hypoglycemia awareness (Clarke score [<i>d</i> = 1.18]), reduced hypoglycemia severity (HYPO score [<i>d</i> = 2.13]), reduced sleep-associated hypoglycemia (percent time glucose was < 54 mg/dL, < 60 mg/dL,< 70 mg/dL; <i>d</i> = 0.66-0.81), and reduced glucose variability (LI, <i>d</i> = 0.86; CV, <i>d</i> = 0.62).</p><p><strong>Conclusion: </strong>AID improved sleep initiation and maintenance. Improved awareness of hypoglycemia, reduced hypoglycemia severity, hypoglycemia exposure, and glucose variability preceded sleep improvements.This trial is registered with ClinicalTrials.gov NCT03215914 https://clinicaltrials.gov/ct2/show/NCT03215914.</p>","PeriodicalId":15475,"journal":{"name":"Journal of Diabetes Science and Technology","volume":" ","pages":"1416-1423"},"PeriodicalIF":4.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11528733/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Diabetes Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19322968231182406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study assessed changes in actigraphy-estimated sleep and glycemic outcomes after initiating automated insulin delivery (AID).
Methods: Ten adults with long-standing type 1 diabetes and impaired awareness of hypoglycemia (IAH) participated in an 18-month clinical trial assessing an AID intervention on hypoglycemia and counter-regulatory mechanisms. Data from eight participants (median age = 58 years) with concurrent wrist actigraph and continuous glucose monitoring (CGM) data were used in the present analyses. Actigraphs and CGM measured sleep and glycemic control at baseline (one week) and months 3, 6, 9, 12, 15, and 18 (three weeks) following AID initiation. HypoCount software integrated actigraphy with CGM data to separate wake and sleep-associated glycemic measures. Paired sample t-tests and Cohen's d effect sizes modeled changes and their magnitude in sleep, glycemic control, IAH (Clarke score), hypoglycemia severity (HYPO score), hypoglycemia exposure (CGM), and glycemic variability (lability index [LI]; CGM coefficient-of-variation [CV]) from baseline to 18 months.
Results: Sleep improved from baseline to 18 months (shorter sleep latency [P < .05, d = 1.74], later sleep offset [P < .05, d = 0.90], less wake after sleep onset [P < .01, d = 1.43]). Later sleep onset (d = 0.74) and sleep midpoint (d = 0.77) showed medium effect sizes. Sleep improvements were evident from 12 to 15 months after AID initiation and were preceded by improved hypoglycemia awareness (Clarke score [d = 1.18]), reduced hypoglycemia severity (HYPO score [d = 2.13]), reduced sleep-associated hypoglycemia (percent time glucose was < 54 mg/dL, < 60 mg/dL,< 70 mg/dL; d = 0.66-0.81), and reduced glucose variability (LI, d = 0.86; CV, d = 0.62).
Conclusion: AID improved sleep initiation and maintenance. Improved awareness of hypoglycemia, reduced hypoglycemia severity, hypoglycemia exposure, and glucose variability preceded sleep improvements.This trial is registered with ClinicalTrials.gov NCT03215914 https://clinicaltrials.gov/ct2/show/NCT03215914.
期刊介绍:
The Journal of Diabetes Science and Technology (JDST) is a bi-monthly, peer-reviewed scientific journal published by the Diabetes Technology Society. JDST covers scientific and clinical aspects of diabetes technology including glucose monitoring, insulin and metabolic peptide delivery, the artificial pancreas, digital health, precision medicine, social media, cybersecurity, software for modeling, physiologic monitoring, technology for managing obesity, and diagnostic tests of glycation. The journal also covers the development and use of mobile applications and wireless communication, as well as bioengineered tools such as MEMS, new biomaterials, and nanotechnology to develop new sensors. Articles in JDST cover both basic research and clinical applications of technologies being developed to help people with diabetes.