90Y Contamination in the Interventional Radiology Suite: VARSKIN Estimation of Skin and Eye Injury and Review of Mitigation Strategies.

IF 1 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of nuclear medicine technology Pub Date : 2023-12-05 DOI:10.2967/jnmt.122.265108
Michael Arseneault, George Mawko, Robert J Abraham
{"title":"<sup>90</sup>Y Contamination in the Interventional Radiology Suite: VARSKIN Estimation of Skin and Eye Injury and Review of Mitigation Strategies.","authors":"Michael Arseneault, George Mawko, Robert J Abraham","doi":"10.2967/jnmt.122.265108","DOIUrl":null,"url":null,"abstract":"<p><p>Our objective was to demonstrate, through computer simulations, radiation exposure levels from a <sup>90</sup>Y contamination event during radioembolization procedures to calculate the radiation doses from various contamination scenarios. We also provide reasonable safety protocols to prevent contamination and minimize radiation exposure during decontamination. <b>Methods:</b> Simulations were performed using the computer code VARSKIN+, version 1.0, to determine the amount of radiation exposure resulting from different contamination scenarios. <b>Results:</b> The annual radiation dose limit to the skin and the lens of the eye was exceeded within 23 s of exposure to a 44-MBq droplet. Double layers of surgical gloves and level 3 gowns provided some attenuation of radiation from <sup>90</sup>Y contamination by reducing the dose rate by 39% and 44%, respectively. Two layers of surgical gloves offered the best ratio of radiation protection without compromising dexterity. <b>Conclusion:</b> This study demonstrated that radiation exposures during <sup>90</sup>Y spills or contamination events can be considerable. Interventional radiology and nuclear medicine personnel must be mindful of the risks, follow strategies to prevent spills, and be familiar with recommended decontamination procedures for spills in the interventional radiology suite.</p>","PeriodicalId":16548,"journal":{"name":"Journal of nuclear medicine technology","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nuclear medicine technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnmt.122.265108","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Our objective was to demonstrate, through computer simulations, radiation exposure levels from a 90Y contamination event during radioembolization procedures to calculate the radiation doses from various contamination scenarios. We also provide reasonable safety protocols to prevent contamination and minimize radiation exposure during decontamination. Methods: Simulations were performed using the computer code VARSKIN+, version 1.0, to determine the amount of radiation exposure resulting from different contamination scenarios. Results: The annual radiation dose limit to the skin and the lens of the eye was exceeded within 23 s of exposure to a 44-MBq droplet. Double layers of surgical gloves and level 3 gowns provided some attenuation of radiation from 90Y contamination by reducing the dose rate by 39% and 44%, respectively. Two layers of surgical gloves offered the best ratio of radiation protection without compromising dexterity. Conclusion: This study demonstrated that radiation exposures during 90Y spills or contamination events can be considerable. Interventional radiology and nuclear medicine personnel must be mindful of the risks, follow strategies to prevent spills, and be familiar with recommended decontamination procedures for spills in the interventional radiology suite.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
介入放射套件中的y污染:皮肤和眼睛损伤的VARSKIN评估和缓解策略的回顾
我们的目的是通过计算机模拟证明,在放射栓塞过程中,90Y污染事件的辐射暴露水平,以计算各种污染情况下的辐射剂量。我们还提供合理的安全规程,以防止污染,并在净化过程中尽量减少辐射暴露。方法:采用计算机程序VARSKIN+ 1.0进行模拟,确定不同污染情景下的辐射暴露量。结果:一个44-MBq的微滴暴露在23 s内就超过了皮肤和晶状体的年辐射剂量限制。双层手术手套和3级防护服分别减少39%和44%的剂量率,对来自90Y污染的辐射有一定的衰减。两层手术手套在不影响灵巧性的情况下提供了最佳的辐射防护比例。结论:本研究表明,在90Y泄漏或污染事件中的辐射暴露是相当可观的。介入放射学和核医学人员必须注意风险,遵循防止泄漏的策略,并熟悉介入放射学套件中泄漏的推荐去污程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of nuclear medicine technology
Journal of nuclear medicine technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.90
自引率
15.40%
发文量
57
期刊最新文献
Comment Regarding "Vapocoolant Analgesia for Breast Lymphoscintigraphy: A Prospective Clinical Trial". Navigating a Transatlantic Career Shift: Guidance for U.S. Nuclear Medicine Technologists Looking to Relocate to the U.K. So You Are a Clinical Instructor-Now What? The Effect of Monitored Walking on Extracardiac Intestinal Activity in Myocardial Perfusion Imaging. A Multiradionuclide Automatic Dispensing System for Syringes of Radiopharmaceuticals: The Effect on Operator Hand Dose.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1