{"title":"T1 Mapping for Differentiating of Haemorrhagic Transformation from Extravasation of Iodine Contrast Agents: A Phantom Study.","authors":"Rong Liu,&nbsp;Sunyu Hua,&nbsp;Chaogang Wei,&nbsp;Wu Cai,&nbsp;Chao Sun","doi":"10.29271/jcpsp.2023.07.742","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate T1 mapping values in different concentrations of iodine and mixed blood and to simulate the application of T1 mapping in differentiating iodine contrast extravasation and haemorrhage transformation after revascularisation in acute ischemic stroke.</p><p><strong>Study design: </strong>A phantom-based experimental study. Place and Duration of the Study: Department of Radiology, the Second Affiliated Hospital of Soochow University, China, from October 2020 to December 2021.</p><p><strong>Methodology: </strong>Fresh blood, pure iodine, blood-iodine mixtures (75/25, 50/50, and 25/75 ratios), and diluted iodine (at a concentration of 2.1 mmol I/L) were scanned in a phantom on 3-T MR T1 mapping imaging. A total of 10 layers in the middle section of tubes were scanned. The mean value of T1 mapping and 95% confidence interval for the investigated sample compositions were calculated and compared by ANOVA.</p><p><strong>Results: </strong>The mean values (95% CI) for fresh blood, [2/3] blood +[1/3] iodine, [1/2] blood +[1/2] iodine, [1/3] blood +[2/3] iodine, and pure iodine were 2108.69 ± 1966.68-2250.71(ms), 1991.72 ± 1763.22-2220.21(ms), 1811.62 ± 1614.79-2008.45(ms), 1624.39 ± 1442.41-1806.37(ms), 1294.68 ± 1172.92-1416.44(ms), respectively. The differences between the T1 mapping values of all compositions were significant (p <0.01), except for fresh blood and the sample consisting of 67% blood. The mean value on T1 mapping (95% CI) was 1294.68 ± 1172.92-1416.44 (ms) in the samples only with diluted iodine, which was significantly different from other investigated samples (p <0.01). The intra-class correlation coefficient between the two times drawing of radiologist A was excellent (ICC=0.913, p<0.01), and between radiologists A and B was 0.99.</p><p><strong>Conclusion: </strong>Iodine contrast extravasation in a phantom setting might be distinguished from haemorrhagic transformation using T1 mapping.</p><p><strong>Key words: </strong>Acute ischemic stroke, Haemorrhage transformation, Contrast extravasation, Magnetic resonance imaging, T1 mapping, 3T MRI.</p>","PeriodicalId":54905,"journal":{"name":"Jcpsp-Journal of the College of Physicians and Surgeons Pakistan","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jcpsp-Journal of the College of Physicians and Surgeons Pakistan","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.29271/jcpsp.2023.07.742","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate T1 mapping values in different concentrations of iodine and mixed blood and to simulate the application of T1 mapping in differentiating iodine contrast extravasation and haemorrhage transformation after revascularisation in acute ischemic stroke.

Study design: A phantom-based experimental study. Place and Duration of the Study: Department of Radiology, the Second Affiliated Hospital of Soochow University, China, from October 2020 to December 2021.

Methodology: Fresh blood, pure iodine, blood-iodine mixtures (75/25, 50/50, and 25/75 ratios), and diluted iodine (at a concentration of 2.1 mmol I/L) were scanned in a phantom on 3-T MR T1 mapping imaging. A total of 10 layers in the middle section of tubes were scanned. The mean value of T1 mapping and 95% confidence interval for the investigated sample compositions were calculated and compared by ANOVA.

Results: The mean values (95% CI) for fresh blood, [2/3] blood +[1/3] iodine, [1/2] blood +[1/2] iodine, [1/3] blood +[2/3] iodine, and pure iodine were 2108.69 ± 1966.68-2250.71(ms), 1991.72 ± 1763.22-2220.21(ms), 1811.62 ± 1614.79-2008.45(ms), 1624.39 ± 1442.41-1806.37(ms), 1294.68 ± 1172.92-1416.44(ms), respectively. The differences between the T1 mapping values of all compositions were significant (p <0.01), except for fresh blood and the sample consisting of 67% blood. The mean value on T1 mapping (95% CI) was 1294.68 ± 1172.92-1416.44 (ms) in the samples only with diluted iodine, which was significantly different from other investigated samples (p <0.01). The intra-class correlation coefficient between the two times drawing of radiologist A was excellent (ICC=0.913, p<0.01), and between radiologists A and B was 0.99.

Conclusion: Iodine contrast extravasation in a phantom setting might be distinguished from haemorrhagic transformation using T1 mapping.

Key words: Acute ischemic stroke, Haemorrhage transformation, Contrast extravasation, Magnetic resonance imaging, T1 mapping, 3T MRI.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
T1定位鉴别出血性转化与碘造影剂外渗:一项幻象研究。
目的:评价不同浓度碘和混合血T1测图的价值,模拟T1测图在急性缺血性脑卒中碘造影剂外渗和血运重建后出血转化鉴别中的应用。研究设计:基于幻影的实验研究。研究地点和时间:中国苏州大学第二附属医院放射科,2020年10月至2021年12月。方法:对新鲜血液、纯碘、血碘混合物(75/ 25,50 /50和25/75的比例)和稀释碘(浓度为2.1 mmol I/L)在3-T MR T1成像上进行扫描。共扫描管内中段10层。计算被调查样本组成的T1映射平均值和95%置信区间,并通过方差分析进行比较。结果:新鲜血、[2/3]血+[1/3]碘、[1/2]血+[1/2]碘、[1/3]血+[2/ 2]碘、[1/3]血+[2/3]碘、纯碘的平均值(95% CI)分别为2108.69±1966.68 ~ 2250.71(ms)、1991.72±1763.22 ~ 2220.21(ms)、1811.62±1614.79 ~ 2008.45(ms)、1624.39±1442.41 ~ 1806.37(ms)、1294.68±1172.92 ~ 1416.44(ms)。结论:碘造影剂外渗可以通过T1定位与出血转化区分开来。关键词:急性缺血性卒中,出血转化,造影剂外渗,磁共振成像,T1定位,3T MRI。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
453
审稿时长
3-6 weeks
期刊介绍: Journal of College of Physicians and Surgeons Pakistan (JCPSP), is the prestigious, peer reviewed monthly biomedical journal of the country published regularly since 1991. Established with the primary aim of promotion and dissemination of medical research and contributed by scholars of biomedical sciences from Pakistan and abroad, it carries original research papers, , case reports, review articles, articles on medical education, commentaries, short communication, new technology, editorials and letters to the editor. It covers the core biomedical health science subjects, basic medical sciences and emerging community problems, prepared in accordance with the “Uniform requirements for submission to bio-medical journals” laid down by International Committee of Medical Journals Editors (ICMJE). All publications of JCPSP are peer reviewed by subject specialists from Pakistan and locally and abroad.
期刊最新文献
Changes in Corneal Biomechanical Properties after Laser-Assisted in situ Keratomileusis and Photorefractive Keratectomy in Myopia. Efficacy of Endotracheal Tube Cuff Modification in Preventing Ventilator-associated Pneumonia. Comparison of Rapid Antigen Detection Test with Reverse Transcription Polymerase Chain Reaction in Highly Suspected COVID-19 Patients. Cervical Mediastinoscopy as a Diagnostic Tool for Mediastinal Lymphadenopathy. Proposing Development of Community-based Physical Activity Park for Elderly Population of Pakistan.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1