William G Hamilton, Robert A Sershon, Anshu Gupta, Laura Goldstein, Mina Kabiri, Chantal E Holy, Rodrigo Diaz
{"title":"Readmission rate and healthcare utilization outcomes of computer-assisted fluoroscopy-based hip navigation versus manual total hip arthroplasty.","authors":"William G Hamilton, Robert A Sershon, Anshu Gupta, Laura Goldstein, Mina Kabiri, Chantal E Holy, Rodrigo Diaz","doi":"10.1080/17434440.2023.2238609","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The study evaluates the technology of fluoroscopy-based hip navigation that has shown to improve implant positioning in total hip arthroplasty (THA).</p><p><strong>Methods: </strong>Premier Healthcare data for patients undergoing manual THA or fluoroscopy-based hip navigation THA between 1 January 2016-30 September 2021, were analyzed 90- and 365-day post-THA. The primary outcome was inpatient readmission. Secondary outcomes were operating room (OR) time, length of stay, discharge status, and hospital costs. Baseline covariate differences were balanced using fine stratification and analyzed using generalized linear models.</p><p><strong>Results: </strong>Among 4,080 fluoroscopy-based hip navigation THA and 429,533 manual THA balanced patients, hip-related readmission rates were statistically significantly lower for the fluoroscopy-based hip navigation THA cohort vs. manual THA for both 90-day (odd ratio [95% CI]: 0.69 [0.52 to 0.91] and 365-day (0.63 [0.49 to 0.81] follow-up. OR time was higher with fluoroscopy-based hip navigation THA vs. manual THA (134.65 vs. 132.04 minutes); however, fluoroscopy-based hip navigation THA patients were more likely to be discharged to home (93.73% vs. 90.11%) vs. manual THA. Hospital costs were not different between cohorts at 90- and 365-day post-operative.</p><p><strong>Conclusions: </strong>Fluoroscopy-based hip navigation THA resulted in fewer readmissions, greater discharge to home, and similar hospital costs compared to manual THA.</p>","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":"20 9","pages":"779-789"},"PeriodicalIF":2.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Medical Devices","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2238609","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: The study evaluates the technology of fluoroscopy-based hip navigation that has shown to improve implant positioning in total hip arthroplasty (THA).
Methods: Premier Healthcare data for patients undergoing manual THA or fluoroscopy-based hip navigation THA between 1 January 2016-30 September 2021, were analyzed 90- and 365-day post-THA. The primary outcome was inpatient readmission. Secondary outcomes were operating room (OR) time, length of stay, discharge status, and hospital costs. Baseline covariate differences were balanced using fine stratification and analyzed using generalized linear models.
Results: Among 4,080 fluoroscopy-based hip navigation THA and 429,533 manual THA balanced patients, hip-related readmission rates were statistically significantly lower for the fluoroscopy-based hip navigation THA cohort vs. manual THA for both 90-day (odd ratio [95% CI]: 0.69 [0.52 to 0.91] and 365-day (0.63 [0.49 to 0.81] follow-up. OR time was higher with fluoroscopy-based hip navigation THA vs. manual THA (134.65 vs. 132.04 minutes); however, fluoroscopy-based hip navigation THA patients were more likely to be discharged to home (93.73% vs. 90.11%) vs. manual THA. Hospital costs were not different between cohorts at 90- and 365-day post-operative.
Conclusions: Fluoroscopy-based hip navigation THA resulted in fewer readmissions, greater discharge to home, and similar hospital costs compared to manual THA.
期刊介绍:
The journal serves the device research community by providing a comprehensive body of high-quality information from leading experts, all subject to rigorous peer review. The Expert Review format is specially structured to optimize the value of the information to reader. Comprehensive coverage by each author in a key area of research or clinical practice is augmented by the following sections:
Expert commentary - a personal view on the most effective or promising strategies
Five-year view - a clear perspective of future prospects within a realistic timescale
Key issues - an executive summary cutting to the author''s most critical points
In addition to the Review program, each issue also features Medical Device Profiles - objective assessments of specific devices in development or clinical use to help inform clinical practice. There are also Perspectives - overviews highlighting areas of current debate and controversy, together with reports from the conference scene and invited Editorials.