{"title":"Technical concepts on blood pool phase SPECT (acquisition, reconstruction).","authors":"Sarah C Cade,&nbsp;Richard N Graham","doi":"10.23736/S1824-4785.23.03506-9","DOIUrl":null,"url":null,"abstract":"<p><p>Guidelines for bone scintigraphy are well established and recommend the use of planar early phase images to investigate a number of clinical indications. With recent advances in gamma camera technology the use of SPECT/CT imaging in the early phases is now possible, offering the potential of improved diagnostic confidence and prognostic value. To date little work has been carried out to optimize the acquisition of early phase bone images using SPECT/CT with most of the available studies acquiring SPECT images after the traditional planar images to allow comparison of the two techniques. Imaging durations of 7 to 10 minutes have been commonly used. However, the use of iterative reconstruction algorithms has been investigated with rapid SPECT imaging to allow imaging durations as low as 4 minutes. The use of CZT based systems with increased sensitivity and improved energy and spatial resolution also offers the potential to reduce imaging times. The optimization of projection measurement order has been investigated as a method of reducing image artefacts as a result of changing tracer distribution during the SPECT acquisition. In this article we consider the current state of early phase SPECT imaging and possible areas for future investigation as well as recommendations for departments looking to adopt blood pool SPECT imaging as part of their routine clinical practice.</p>","PeriodicalId":23069,"journal":{"name":"The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...","volume":"67 3","pages":"183-190"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S1824-4785.23.03506-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Guidelines for bone scintigraphy are well established and recommend the use of planar early phase images to investigate a number of clinical indications. With recent advances in gamma camera technology the use of SPECT/CT imaging in the early phases is now possible, offering the potential of improved diagnostic confidence and prognostic value. To date little work has been carried out to optimize the acquisition of early phase bone images using SPECT/CT with most of the available studies acquiring SPECT images after the traditional planar images to allow comparison of the two techniques. Imaging durations of 7 to 10 minutes have been commonly used. However, the use of iterative reconstruction algorithms has been investigated with rapid SPECT imaging to allow imaging durations as low as 4 minutes. The use of CZT based systems with increased sensitivity and improved energy and spatial resolution also offers the potential to reduce imaging times. The optimization of projection measurement order has been investigated as a method of reducing image artefacts as a result of changing tracer distribution during the SPECT acquisition. In this article we consider the current state of early phase SPECT imaging and possible areas for future investigation as well as recommendations for departments looking to adopt blood pool SPECT imaging as part of their routine clinical practice.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血池相SPECT的技术概念(采集、重建)。
骨显像指南已经建立,并推荐使用平面早期图像来调查一些临床适应症。随着伽马相机技术的最新进展,在早期阶段使用SPECT/CT成像现在是可能的,提供了提高诊断信心和预后价值的潜力。迄今为止,使用SPECT/CT优化早期骨图像采集的工作很少,大多数可用的研究是在传统的平面图像之后获取SPECT图像,以便对两种技术进行比较。成像时间通常为7 - 10分钟。然而,迭代重建算法的使用已经研究了快速SPECT成像,使成像持续时间低至4分钟。使用基于CZT的系统,具有更高的灵敏度和改进的能量和空间分辨率,也提供了减少成像时间的潜力。研究了优化投影测量顺序的方法,以减少在SPECT采集过程中由于示踪剂分布的改变而产生的图像伪影。在这篇文章中,我们考虑了早期SPECT成像的现状和未来可能研究的领域,以及对希望采用血池SPECT成像作为常规临床实践一部分的部门的建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Toxicity comparison of yttrium-90 resin and glass microspheres radioembolization. Risk factors for rib metastases of lung cancer patients with high-uptake rib foci on 99Tcm-MDP SPECT/CT. Second radioiodine treatment hardly benefits TT-DTC patients with radioiodine-negative metastases on initial post-therapeutic whole-body scans. Total variation regularized expectation maximization reconstruction improves 68Ga-FAPI-04 PET/CT image quality as compared to ordered subset expectation maximization reconstruction. The sentinel node with technetium-99m for prostate cancer. A safe and mature new gold standard?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1