Use of 3D Planning and Patient-specific Guides for Proximal Humerus Corrective Osteotomy Associated With Shoulder Prosthesis Implantation in Proximal Humeral Varus Malunion.

Raffaele Russo, Andrea Cozzolino, Antonio Guastafierro, Giuseppe Della Rotonda, Stefano Viglione, Michele Ciccarelli, Marco Mortellaro, Paolo Minopoli, Fabrizio Fiorentino, Livia R Pietroluongo
{"title":"Use of 3D Planning and Patient-specific Guides for Proximal Humerus Corrective Osteotomy Associated With Shoulder Prosthesis Implantation in Proximal Humeral Varus Malunion.","authors":"Raffaele Russo,&nbsp;Andrea Cozzolino,&nbsp;Antonio Guastafierro,&nbsp;Giuseppe Della Rotonda,&nbsp;Stefano Viglione,&nbsp;Michele Ciccarelli,&nbsp;Marco Mortellaro,&nbsp;Paolo Minopoli,&nbsp;Fabrizio Fiorentino,&nbsp;Livia R Pietroluongo","doi":"10.1097/BTH.0000000000000372","DOIUrl":null,"url":null,"abstract":"<p><p>Humeral stem prosthesis implantation in case of proximal humerus varus malunion (type 1D fracture sequelae) is often complicated by greater tuberosity fracture and by posterosuperior rotator cuff iatrogenic damage. Moreover, the varus malunited humeral head could lead to scapular impingement and reduce the range of motion. To address this problem, we introduced a new surgical procedure consisting in a proximal humerus osteotomy, planned with three-dimensional (3D) preoperative virtual surgery, and performed with patient-specific surgical guides, to correct humerus deformity before the implantation of the prosthetic humeral stem. A 3D evaluation of the deformity, based on the comparison to the healthy contralateral side or to anatomical standard values, is firstly performed. The metaphyseal osteotomy is then planned and virtually performed. To faithfully reproduce the planned correction, 3D printed surgical guides are prepared. Before the surgery, it is advisable to perform a simulation of the planned osteotomies to verify their real feasibility and to find any critical issues. Preliminary outcomes of this surgical technique are encouraging, but formal studies are warranted to validate its clinical utility and longevity of results.</p>","PeriodicalId":39303,"journal":{"name":"Techniques in Hand and Upper Extremity Surgery","volume":"26 2","pages":"131-138"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Hand and Upper Extremity Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTH.0000000000000372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

Abstract

Humeral stem prosthesis implantation in case of proximal humerus varus malunion (type 1D fracture sequelae) is often complicated by greater tuberosity fracture and by posterosuperior rotator cuff iatrogenic damage. Moreover, the varus malunited humeral head could lead to scapular impingement and reduce the range of motion. To address this problem, we introduced a new surgical procedure consisting in a proximal humerus osteotomy, planned with three-dimensional (3D) preoperative virtual surgery, and performed with patient-specific surgical guides, to correct humerus deformity before the implantation of the prosthetic humeral stem. A 3D evaluation of the deformity, based on the comparison to the healthy contralateral side or to anatomical standard values, is firstly performed. The metaphyseal osteotomy is then planned and virtually performed. To faithfully reproduce the planned correction, 3D printed surgical guides are prepared. Before the surgery, it is advisable to perform a simulation of the planned osteotomies to verify their real feasibility and to find any critical issues. Preliminary outcomes of this surgical technique are encouraging, but formal studies are warranted to validate its clinical utility and longevity of results.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肱骨近端矫正截骨联合肩关节假体植入术治疗肱骨近端内翻畸形愈合的3D规划和患者特异性指南的应用
肱骨干假体植入术治疗肱骨近端内翻畸形愈合(1D型骨折后遗症)常并发大结节骨折和后上肩袖医源性损伤。此外,肱骨头畸形内翻可导致肩胛骨撞击和活动范围减小。为了解决这个问题,我们引入了一种新的手术方法,包括肱骨近端截骨术,计划三维(3D)术前虚拟手术,并在患者特定的手术指导下进行,在植入假体肱骨干之前纠正肱骨畸形。首先根据与健康对侧或解剖标准值的比较,对畸形进行三维评估。然后计划并虚拟执行干骺端截骨术。为了忠实地再现计划的矫正,准备了3D打印的手术指南。在手术前,建议对计划的截骨术进行模拟,以验证其真正的可行性并发现任何关键问题。这种手术技术的初步结果是令人鼓舞的,但需要正式的研究来验证其临床应用和结果的持久性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
54
期刊介绍: Techniques in Hand & Upper Extremity Surgery presents authoritative, practical information on today"s advances in hand and upper extremity surgery. It features articles by leading experts on the latest surgical techniques, the newest equipment, and progress in therapies for rehabilitation. The primary focus of the journal is hand surgery, but articles on the wrist, elbow, and shoulder are also included. Major areas covered include arthroscopy, microvascular surgery, plastic surgery, congenital anomalies, tendon and nerve disorders, trauma, and work-related injuries.
期刊最新文献
Surgical Technique: Spinal Accessory to Infraspinatus Nerve Transfer in Brachial Plexus Birth Injury. The Use of Nitinol Staples as Reduction Aids in Fixation of Forearm Diaphyseal Fractures: Surgical Technique and Case Series. Stabilization of the Thumb Carpometacarpal Joint Utilizing a Minimally Invasive Approach: A Novel Technique. Chronic Exertional Compartment Syndrome of the Forearm: Compartment-specific Endoscopic Fasciotomy. Radial Longitudinal Deficiency: Description of a Novel Surgical Technique and Clinical Cases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1