A Cadaveric Simulation Study of Radiation Exposure to the Surgical Team during Fluoroscopic Spinal Surgery: How Much Are We Exposed?

IF 1.2 Q3 SURGERY Spine Surgery and Related Research Pub Date : 2023-07-27 DOI:10.22603/ssrr.2022-0184
Kazuta Yamashita, Yasuaki Tamaki, Daiki Nakajima, Yasuyuki Omichi, Yoshinori Takahashi, Michihiro Takai, Tomohiro Goto, Hiroaki Hayashi, Kosaku Higashino, Yoshihiro Tsuruo, Koichi Sairyo
{"title":"A Cadaveric Simulation Study of Radiation Exposure to the Surgical Team during Fluoroscopic Spinal Surgery: How Much Are We Exposed?","authors":"Kazuta Yamashita, Yasuaki Tamaki, Daiki Nakajima, Yasuyuki Omichi, Yoshinori Takahashi, Michihiro Takai, Tomohiro Goto, Hiroaki Hayashi, Kosaku Higashino, Yoshihiro Tsuruo, Koichi Sairyo","doi":"10.22603/ssrr.2022-0184","DOIUrl":null,"url":null,"abstract":"Introduction The harmful effects of long-term low-dose radiation have been well known. There are few comprehensive reports evaluating concrete real exposure doses for each part of a surgeon, assistant surgeon, scrub nurse, and anesthesiologist associated with fluoroscopic spinal procedures. This research aimed to quantify the radiation exposure dose to surgical team members during C-arm fluoroscopy-guided spinal surgery. Methods Seven fresh cadavers were irradiated for 1 and 3 min with C-arm fluoroscopy. The position of the X-ray source was under the table, over the table, and laterally. The radiation exposure doses were measured at the optic lens, thyroid gland, and hand in mannequins used to simulate surgical team members. Results A significant difference was observed in the radiation exposure dose according to the position of the X-ray source and the irradiated body area. The risk of scatter radiation exposure was the biggest for the lateral position (nearly 30-fold that for the position under the table). All radiation exposure doses were positively correlated with irradiation time. Conclusions The occupational radiation exposure dose to surgical team members during C-arm fluoroscopy-guided lumbar spinal procedures varies according to the X-ray source position. Our findings would help surgical team members to know the risk of radiation exposure during various fluoroscopic procedures. Surgeons in particular need to reduce their radiation exposure by using appropriate shielding and technique.","PeriodicalId":22253,"journal":{"name":"Spine Surgery and Related Research","volume":"7 4","pages":"341-349"},"PeriodicalIF":1.2000,"publicationDate":"2023-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/2d/59/2432-261X-7-0341.PMC10447199.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spine Surgery and Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22603/ssrr.2022-0184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction The harmful effects of long-term low-dose radiation have been well known. There are few comprehensive reports evaluating concrete real exposure doses for each part of a surgeon, assistant surgeon, scrub nurse, and anesthesiologist associated with fluoroscopic spinal procedures. This research aimed to quantify the radiation exposure dose to surgical team members during C-arm fluoroscopy-guided spinal surgery. Methods Seven fresh cadavers were irradiated for 1 and 3 min with C-arm fluoroscopy. The position of the X-ray source was under the table, over the table, and laterally. The radiation exposure doses were measured at the optic lens, thyroid gland, and hand in mannequins used to simulate surgical team members. Results A significant difference was observed in the radiation exposure dose according to the position of the X-ray source and the irradiated body area. The risk of scatter radiation exposure was the biggest for the lateral position (nearly 30-fold that for the position under the table). All radiation exposure doses were positively correlated with irradiation time. Conclusions The occupational radiation exposure dose to surgical team members during C-arm fluoroscopy-guided lumbar spinal procedures varies according to the X-ray source position. Our findings would help surgical team members to know the risk of radiation exposure during various fluoroscopic procedures. Surgeons in particular need to reduce their radiation exposure by using appropriate shielding and technique.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脊柱透视手术期间外科团队辐射暴露的尸体模拟研究:我们暴露了多少?
长期低剂量辐射的有害影响是众所周知的。很少有全面的报告评估与脊柱透视手术相关的外科医生、助理外科医生、擦洗护士和麻醉师的每个部位的具体实际暴露剂量。本研究旨在量化在c臂透视引导下脊柱手术中手术团队成员的辐射暴露剂量。方法:对7具新鲜尸体进行c臂透视照射1、3min。x射线源位置为桌子下、桌子上、侧面。在视状体、甲状腺和用来模拟外科团队成员的人体模型处测量辐射暴露剂量。结果:不同x射线源位置和照射体面积的照射剂量有显著差异。侧卧位的散射辐射暴露风险最大(是桌子下位的近30倍)。所有辐照剂量均与辐照时间呈正相关。结论:在c臂透视引导下的腰椎手术中,手术团队成员的职业辐射暴露剂量随x射线源位置的不同而不同。我们的发现将帮助外科团队成员了解在各种透视过程中辐射暴露的风险。外科医生尤其需要通过使用适当的屏蔽和技术来减少他们的辐射暴露。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
71
审稿时长
15 weeks
期刊最新文献
A Case of Early Onset Scoliosis with Trisomy 1q and Monosomy 21q. Artificial Intelligence Classification for Detecting and Grading Lumbar Intervertebral Disc Degeneration. A Case of Desmoplastic Fibroma of the Thoracic Spine with Incomplete Paralysis of both Lower Limbs. Transcostal Microendoscopic Discectomy for Central Thoracic Disc Herniation Causing Myelopathy: A Technical Note. Posterior Column Reconstruction of the Lumbar Spine Using En Bloc Resected Vertebral Arch in Spinal Tumor and Deformity Surgeries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1