Evaluation of the effect of different rubber dam clamps on the mandibular first molar with Finite element analysis.

IF 1.7 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS Computer Methods in Biomechanics and Biomedical Engineering Pub Date : 2024-09-01 Epub Date: 2023-09-07 DOI:10.1080/10255842.2023.2254882
Mehmet Eskibağlar, Serkan Erdem, Mete Onur Kaman
{"title":"Evaluation of the effect of different rubber dam clamps on the mandibular first molar with Finite element analysis.","authors":"Mehmet Eskibağlar, Serkan Erdem, Mete Onur Kaman","doi":"10.1080/10255842.2023.2254882","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the stress induced by clamps made of different materials on mandibular first molar teeth using finite element analysis. The tooth model to be used in the study was created using micro-CT scanner and the rubber dam clamp model was created in three dimensions (3D) using Solidworks and applied to a finite element tooth model of an intact mandibular first molar. The size of the clamp opening and the force to be applied were calculated according to the buccolingual distances of the tooth. The contact areas of the clamps on the tooth were determined and subjected to force. The stress distribution patterns and maximum von Mises stresses were calculated and compared against these forces. The most stress against these forces occurred in the enamel tissue on the distal side where the clamp was in contact with the tooth. The stress value in the stainless steel clamp (191.63 MPa) was approximately 85% higher than the clamp made of polyethylene ketone (103.85 MPa). The stress in the dentin and pulp tissue of the tooth was negligible. Clinicians should examine the enamel tissue below the equatorial line of the tooth in detail before clamp application. The forces exerted by stainless steel clamps can cause damage to the enamel tissue of the tooth or progression of an existing enamel crack.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2023.2254882","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to evaluate the stress induced by clamps made of different materials on mandibular first molar teeth using finite element analysis. The tooth model to be used in the study was created using micro-CT scanner and the rubber dam clamp model was created in three dimensions (3D) using Solidworks and applied to a finite element tooth model of an intact mandibular first molar. The size of the clamp opening and the force to be applied were calculated according to the buccolingual distances of the tooth. The contact areas of the clamps on the tooth were determined and subjected to force. The stress distribution patterns and maximum von Mises stresses were calculated and compared against these forces. The most stress against these forces occurred in the enamel tissue on the distal side where the clamp was in contact with the tooth. The stress value in the stainless steel clamp (191.63 MPa) was approximately 85% higher than the clamp made of polyethylene ketone (103.85 MPa). The stress in the dentin and pulp tissue of the tooth was negligible. Clinicians should examine the enamel tissue below the equatorial line of the tooth in detail before clamp application. The forces exerted by stainless steel clamps can cause damage to the enamel tissue of the tooth or progression of an existing enamel crack.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过有限元分析评估不同橡胶坝夹对下颌第一磨牙的影响。
本研究的目的是利用有限元分析评估不同材料制成的夹钳在下颌第一磨牙上引起的应力。研究中使用的牙齿模型是用微型 CT 扫描仪制作的,橡胶坝夹模型是用 Solidworks 制作的三维(3D)模型,并应用于完整下颌第一磨牙的有限元牙齿模型。根据牙齿的颊舌距离计算出夹钳开口的大小和施加的力。确定了夹钳在牙齿上的接触面积,并对其施加了力。计算应力分布模式和最大 von Mises 应力,并与这些力进行比较。在这些力的作用下,夹钳与牙齿接触的远侧珐琅质组织的应力最大。不锈钢牙夹的应力值(191.63 兆帕)比聚乙烯酮牙夹(103.85 兆帕)高出约 85%。牙本质和牙髓组织中的应力可以忽略不计。临床医生在使用夹钳前应详细检查牙齿赤道线以下的珐琅质组织。不锈钢牙夹施加的力可能会对牙齿的珐琅质组织造成损害,或使现有的珐琅质裂纹继续发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
期刊最新文献
Reconstruction of blood flow velocity with deep learning information fusion from spectral ct projections and vessel geometry. Reduction of material groups for vertebral bone finite element simulation: cross comparison of grouping methods. Accurate detection of gait events using neural networks and IMU data mimicking real-world smartphone usage. Exploring coronavirus sequence motifs through convolutional neural network for accurate identification of COVID-19. Coexistence of horizontal bone loss and dehiscence with the bundle and conventional fiber post: a finite element analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1