{"title":"Reliability of implant stability measuring devices depending on various clinical conditions: an <i>in vitro</i> study.","authors":"Han-Na Lee,&nbsp;Myoung-Sub Kim,&nbsp;Jeong-Yol Lee,&nbsp;Xu Zihan,&nbsp;Jae-Jun Ryu,&nbsp;Ji-Suk Shim","doi":"10.4047/jap.2023.15.3.126","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient.</p><p><strong>Materials and methods: </strong>Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent <i>t</i>-test.</p><p><strong>Results: </strong>Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (<i>P</i> < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (<i>P</i> < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (<i>P</i> < .05).</p><p><strong>Conclusion: </strong>In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/32/f2/jap-15-126.PMC10333099.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2023.15.3.126","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient.

Materials and methods: Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test.

Results: Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05).

Conclusion: In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
种植体稳定性测量装置的可靠性取决于不同的临床条件:一项体外研究。
目的:本研究的目的是评估种植体稳定性测量装置的可靠性,这取决于种植体的位置和患者的位置。材料与方法:将6个种植体安装在6个人工骨模型的不同齿状六分仪上。在骨模型的三种情况下(不安装在虚幻头上,安装在仰卧位的虚幻头上,安装在直立位置的虚幻头上)测量植入物的稳定性。使用一个共振频率分析装置(Osstell)和两个阻尼容量分析装置(Periotest和Anycheck)来测量种植体的稳定性。幻象头外测量值作为对照,幻象头内测量值采用独立t检验进行比较。结果:Osstell在仰卧位和直立位的6个分区中有2个分区的结果与口腔外不同(P < 0.05)。仰卧位的6个部位和直立位的5个部位的骨膜检查结果与口腔外比较差异有统计学意义(P < 0.05)。而Anycheck在仰卧位与口外位的5个区域显示不同的结果,在直立位只有1个区域显示不同的结果(P < 0.05)。结论:在操作人员难以接近种植体位置时,种植体稳定性测量装置的可靠性较差。影响种植体可及性的顺序依次为Osstell、Anycheck、Periotest。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
期刊最新文献
A novel brief questionnaire using a face rating scale to assess dental anxiety and fear. Clinical performance of implant-assisted removable partial dentures using implant surveyed crowns: a systematic review and meta-analysis. Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis. Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study. Recording maximal intercuspation and border positions of the mandible with intraoral scanner using the acquisition software's multi-occlusion function.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1