The Impact of Patient Factors on Objective Cochlear Implant Verification Using Acoustic Cortical Auditory-Evoked Potentials.

IF 1.6 4区 医学 Q2 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY Audiology and Neuro-Otology Pub Date : 2024-01-01 Epub Date: 2023-09-08 DOI:10.1159/000533273
Caris Bogdanov, Wilhelmina H A M Mulders, Helen Goulios, Dayse Távora-Vieira
{"title":"The Impact of Patient Factors on Objective Cochlear Implant Verification Using Acoustic Cortical Auditory-Evoked Potentials.","authors":"Caris Bogdanov, Wilhelmina H A M Mulders, Helen Goulios, Dayse Távora-Vieira","doi":"10.1159/000533273","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Hearing loss is a major global public health issue that negatively impacts quality of life, communication, cognition, social participation, and mental health. The cochlear implant (CI) is the most efficacious treatment for severe-to-profound sensorineural hearing loss. However, variability in outcomes remains high among CI users. Our previous research demonstrated that the existing subjective methodology of CI programming does not consistently produce optimal stimulation for speech perception, thereby limiting the potential for CI users to derive the maximum device benefit to achieve their peak potential. We demonstrated the benefit of utilising the objective method of measuring auditory-evoked cortical responses to speech stimuli as a reliable tool to guide and verify CI programming and, in turn, significantly improve speech perception performance. The present study was designed to investigate the impact of patient- and device-specific factors on the application of acoustically-evoked cortical auditory-evoked potential (aCAEP) measures as an objective clinical tool to verify CI mapping in adult CI users with bilateral deafness (BD).</p><p><strong>Methods: </strong>aCAEP responses were elicited using binaural peripheral auditory stimulation for four speech tokens (/m/, /g/, /t/, and /s/) and recorded by HEARLab™ software in adult BD CI users. Participants were classified into groups according to subjective or objective CI mapping procedures to elicit present aCAEP responses to all four speech tokens. The impact of patient- and device-specific factors on the presence of aCAEP responses and speech perception was investigated between participant groups.</p><p><strong>Results: </strong>Participants were categorised based on the presence or absence of the P1-N1-P2 aCAEP response to speech tokens. Out of the total cohort of adult CI users (n = 132), 63 participants demonstrated present responses pre-optimisation, 37 participants exhibited present responses post-optimisation, and the remaining 32 participants either showed an absent response for at least one speech token post-optimisation or did not accept the optimised CI map adjustments. Overall, no significant correlation was shown between patient and device-specific factors and the presence of aCAEP responses or speech perception scores.</p><p><strong>Conclusion: </strong>This study reinforces that aCAEP measures offer an objective, non-invasive approach to verify CI mapping, irrespective of patient or device factors. These findings further our understanding of the importance of personalised CI rehabilitation through CI mapping to minimise the degree of speech perception variation post-CI and allow all CI users to achieve maximum device benefit.</p>","PeriodicalId":55432,"journal":{"name":"Audiology and Neuro-Otology","volume":" ","pages":"96-106"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10994594/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology and Neuro-Otology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000533273","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Hearing loss is a major global public health issue that negatively impacts quality of life, communication, cognition, social participation, and mental health. The cochlear implant (CI) is the most efficacious treatment for severe-to-profound sensorineural hearing loss. However, variability in outcomes remains high among CI users. Our previous research demonstrated that the existing subjective methodology of CI programming does not consistently produce optimal stimulation for speech perception, thereby limiting the potential for CI users to derive the maximum device benefit to achieve their peak potential. We demonstrated the benefit of utilising the objective method of measuring auditory-evoked cortical responses to speech stimuli as a reliable tool to guide and verify CI programming and, in turn, significantly improve speech perception performance. The present study was designed to investigate the impact of patient- and device-specific factors on the application of acoustically-evoked cortical auditory-evoked potential (aCAEP) measures as an objective clinical tool to verify CI mapping in adult CI users with bilateral deafness (BD).

Methods: aCAEP responses were elicited using binaural peripheral auditory stimulation for four speech tokens (/m/, /g/, /t/, and /s/) and recorded by HEARLab™ software in adult BD CI users. Participants were classified into groups according to subjective or objective CI mapping procedures to elicit present aCAEP responses to all four speech tokens. The impact of patient- and device-specific factors on the presence of aCAEP responses and speech perception was investigated between participant groups.

Results: Participants were categorised based on the presence or absence of the P1-N1-P2 aCAEP response to speech tokens. Out of the total cohort of adult CI users (n = 132), 63 participants demonstrated present responses pre-optimisation, 37 participants exhibited present responses post-optimisation, and the remaining 32 participants either showed an absent response for at least one speech token post-optimisation or did not accept the optimised CI map adjustments. Overall, no significant correlation was shown between patient and device-specific factors and the presence of aCAEP responses or speech perception scores.

Conclusion: This study reinforces that aCAEP measures offer an objective, non-invasive approach to verify CI mapping, irrespective of patient or device factors. These findings further our understanding of the importance of personalised CI rehabilitation through CI mapping to minimise the degree of speech perception variation post-CI and allow all CI users to achieve maximum device benefit.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
患者因素对使用听觉皮层听觉诱发电位进行客观人工耳蜗植入验证的影响
引言听力损失是一个重大的全球公共卫生问题,对生活质量、沟通、认知、社会参与和心理健康都有负面影响。人工耳蜗(CI)是治疗重度至永久性感音神经性听力损失最有效的方法。然而,CI 使用者之间的疗效差异仍然很大。我们之前的研究表明,现有的 CI 编程主观方法并不能始终如一地为言语感知提供最佳刺激,从而限制了 CI 用户从设备中获得最大益处以实现其最大潜能的可能性。我们证明了利用客观方法测量听觉诱发皮层对语音刺激的反应的益处,该方法是指导和验证 CI 编程的可靠工具,可显著提高语音感知性能。本研究旨在调查患者和设备特定因素对应用声学诱发皮层听觉诱发电位(aCAEP)测量作为客观临床工具来验证双侧耳聋(BD)成人 CI 用户的 CI 映射的影响。方法:使用双耳外周听觉刺激对四种语音标记(/m/、/g/、/t/和/s/)诱发 aCAEP 反应,并通过 HEARLab™ 软件记录 BD 成人 CI 用户的反应。根据主观或客观的 CI 映射程序将参与者分为不同组别,以激发他们对所有四个语音标记的 aCAEP 反应。研究了患者和设备特异性因素对各组参与者的 aCAEP 反应和言语感知的影响:结果:研究人员根据患者是否出现 P1-N1-P2 aCAEP 对语音符号的反应对参与者进行了分类。在所有成年 CI 用户(n = 132)中,63 名参与者在优化前表现出存在反应,37 名参与者在优化后表现出存在反应,其余 32 名参与者要么在优化后对至少一个语音标记表现出无反应,要么不接受优化后的 CI 地图调整。总体而言,患者和设备的特定因素与出现 aCAEP 反应或言语感知评分之间没有明显的相关性:本研究证实了 aCAEP 测量可提供一种客观、无创的方法来验证 CI 映射,而不受患者或设备因素的影响。这些发现让我们进一步了解了通过 CI 映射进行个性化 CI 康复的重要性,从而将 CI 后的言语感知变化程度降至最低,使所有 CI 用户都能获得最大的设备效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Audiology and Neuro-Otology
Audiology and Neuro-Otology 医学-耳鼻喉科学
CiteScore
3.20
自引率
6.20%
发文量
35
审稿时长
>12 weeks
期刊介绍: ''Audiology and Neurotology'' provides a forum for the publication of the most-advanced and rigorous scientific research related to the basic science and clinical aspects of the auditory and vestibular system and diseases of the ear. This journal seeks submission of cutting edge research opening up new and innovative fields of study that may improve our understanding and treatment of patients with disorders of the auditory and vestibular systems, their central connections and their perception in the central nervous system. In addition to original papers the journal also offers invited review articles on current topics written by leading experts in the field. The journal is of primary importance for all scientists and practitioners interested in audiology, otology and neurotology, auditory neurosciences and related disciplines.
期刊最新文献
Predicting hearing aids outcomes using machine learning. Concentration dependent effects of human Cometin on spiral ganglion neuron survival and neurite outgrowth. Early deficits in speech perception in carriers of the p.Pro51Ser variant in the COCH gene: a prospective longitudinal evaluation of speech perception in quiet and noise. Social Life and Communication Skills of School-Age Children with Congenital Hearing Loss Who Received Cochlear Implants at an Advanced Age. Comparative effectiveness of the exact versus estimated angle of head position in the Epley maneuver: a randomized controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1