Leilei Zhao, Jianshe Zhao, Changyou Ma, Yi Lu, Chunhua Dong
{"title":"Diagnostic Performance of 3D-NERVE as an Adjunct to Electromyography for the Assessment of Brachial Plexus Injury in Infants.","authors":"Leilei Zhao, Jianshe Zhao, Changyou Ma, Yi Lu, Chunhua Dong","doi":"10.1177/08830738231200301","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> This study aimed to explore diagnostic performance of 3D-NERVE as an adjunct to electromyography for the assessment of brachial plexus injury in infants. <b>Methods:</b> Imaging of infants with brachial plexus injury using 3D-NERVE and/or 3D-STIR from 2019 to 2022 were reviewed. Images were evaluated between the 2 sequences for nerve-to-fat ratio, nerve-to-muscle ratio, muscle-to-fat ratio, fat suppression homogeneity, and display rate of brachial plexus branches. <b>Results:</b> This study included 37 infants who were referred for a clinical diagnosis of brachial plexus injury. A total of 21 infants accepted 3D-NERVE sequence scanning, and 16 infants accepted 3D-NERVE and 3D-STIR sequences scanning. The results of examination were generally consistent with electromyography. The 2 sequences were compared, yielding the following results. There were no pulsation artifacts (0/16), and 1 case with heterogeneous fat saturation (1/16) was seen on 3D-NERVE. There were no pulsation artifacts (0/16), and 5 cases with heterogeneous fat saturation (5/16) were seen on 3D-STIR. 3D-NERVE performed better (<i>P</i> < .05) for nerve-to-fat and nerve-to-muscle ratios compared with 3D-STIR, and no significant difference in the muscle-to-fat ratio (<i>P</i> > .05). The 3D-NERVE and STIR helped depict 100% (16/16) of the brachial roots and brachial plexus trunk. Brachial plexus bundles and brachial plexus branches were observed in 93.75% (15/16) and 68.75% (11/16) of the 3D-NERVE and 93.75% (15/16) and 62.5% (10/16) of the 3D-STIR, respectively. The differences were not statistically significant (<i>P</i> > .05). <b>Conclusion:</b> Nerve trauma was better visualized with the 3D-NERVE, which is an effective adjunct to electromyography for doctors to assess brachial plexus injury and consequently helps in better treatment planning.</p>","PeriodicalId":15319,"journal":{"name":"Journal of Child Neurology","volume":" ","pages":"617-621"},"PeriodicalIF":2.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Child Neurology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08830738231200301","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: This study aimed to explore diagnostic performance of 3D-NERVE as an adjunct to electromyography for the assessment of brachial plexus injury in infants. Methods: Imaging of infants with brachial plexus injury using 3D-NERVE and/or 3D-STIR from 2019 to 2022 were reviewed. Images were evaluated between the 2 sequences for nerve-to-fat ratio, nerve-to-muscle ratio, muscle-to-fat ratio, fat suppression homogeneity, and display rate of brachial plexus branches. Results: This study included 37 infants who were referred for a clinical diagnosis of brachial plexus injury. A total of 21 infants accepted 3D-NERVE sequence scanning, and 16 infants accepted 3D-NERVE and 3D-STIR sequences scanning. The results of examination were generally consistent with electromyography. The 2 sequences were compared, yielding the following results. There were no pulsation artifacts (0/16), and 1 case with heterogeneous fat saturation (1/16) was seen on 3D-NERVE. There were no pulsation artifacts (0/16), and 5 cases with heterogeneous fat saturation (5/16) were seen on 3D-STIR. 3D-NERVE performed better (P < .05) for nerve-to-fat and nerve-to-muscle ratios compared with 3D-STIR, and no significant difference in the muscle-to-fat ratio (P > .05). The 3D-NERVE and STIR helped depict 100% (16/16) of the brachial roots and brachial plexus trunk. Brachial plexus bundles and brachial plexus branches were observed in 93.75% (15/16) and 68.75% (11/16) of the 3D-NERVE and 93.75% (15/16) and 62.5% (10/16) of the 3D-STIR, respectively. The differences were not statistically significant (P > .05). Conclusion: Nerve trauma was better visualized with the 3D-NERVE, which is an effective adjunct to electromyography for doctors to assess brachial plexus injury and consequently helps in better treatment planning.
期刊介绍:
The Journal of Child Neurology (JCN) embraces peer-reviewed clinical and investigative studies from a wide-variety of neuroscience disciplines. Focusing on the needs of neurologic patients from birth to age 18 years, JCN covers topics ranging from assessment of new and changing therapies and procedures; diagnosis, evaluation, and management of neurologic, neuropsychiatric, and neurodevelopmental disorders; and pathophysiology of central nervous system diseases.