{"title":"Finite Element Analysis of Occlusal Interferences in Dental Prosthetics Caused by Occlusal Adjustment.","authors":"Alois Schmid, Thomas Strasser, Martin Rosentritt","doi":"10.11607/ijp.7178","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the influence of occlusal interference using finite element analysis (FEA).</p><p><strong>Materials and methods: </strong>The FEA model designed for this study centered on an all-ceramic, bilayered, fixed partial denture (FPD) retained on the maxillary first premolar and first molar, with the second premolar replaced by a pontic. The surrounding structures-such as the neighboring teeth, antagonists, and periodontium-were modeled. Four different loading cases were designed at occlusal interferences of 0, 8, 12, and 24 μm and were loaded by a simulated bite force of 300 N. Principal and von Mises stresses, as well as strain, were evaluated for all included structures.</p><p><strong>Results: </strong>For interferences of 12 and 24 μm, failure-relevant tensile stresses in the veneering layer were observed at the occlusal surfaces. Stress found in the zirconia FPD did not reach fatigue or flexural strength for any test load.</p><p><strong>Conclusion: </strong>Peak tensile stress was observed in close proximity to occlusal contact points, increasing with increasing occlusal interference. The FEA results suggest that the majority of occlusal stress is absorbed by the deformation of the periodontal ligament. Framework failure caused by the simulated interferences was not expected. Surface defects may ultimately lead to failure due to fracture or chipping, especially in cases of weaker ceramics or veneering.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 4","pages":"436-442"},"PeriodicalIF":2.1000,"publicationDate":"2023-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7178","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3
Abstract
Purpose: To investigate the influence of occlusal interference using finite element analysis (FEA).
Materials and methods: The FEA model designed for this study centered on an all-ceramic, bilayered, fixed partial denture (FPD) retained on the maxillary first premolar and first molar, with the second premolar replaced by a pontic. The surrounding structures-such as the neighboring teeth, antagonists, and periodontium-were modeled. Four different loading cases were designed at occlusal interferences of 0, 8, 12, and 24 μm and were loaded by a simulated bite force of 300 N. Principal and von Mises stresses, as well as strain, were evaluated for all included structures.
Results: For interferences of 12 and 24 μm, failure-relevant tensile stresses in the veneering layer were observed at the occlusal surfaces. Stress found in the zirconia FPD did not reach fatigue or flexural strength for any test load.
Conclusion: Peak tensile stress was observed in close proximity to occlusal contact points, increasing with increasing occlusal interference. The FEA results suggest that the majority of occlusal stress is absorbed by the deformation of the periodontal ligament. Framework failure caused by the simulated interferences was not expected. Surface defects may ultimately lead to failure due to fracture or chipping, especially in cases of weaker ceramics or veneering.
期刊介绍:
Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP)
Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.