The Use of Oxygen/Air Blender during Transoral Laser Microsurgery with Supraglottic Manual Jet Ventilation: A Safe Approach.

Q3 Medicine Case Reports in Anesthesiology Pub Date : 2023-01-01 DOI:10.1155/2023/5516988
Sara Abu-Ghanem, James Cochran
{"title":"The Use of Oxygen/Air Blender during Transoral Laser Microsurgery with Supraglottic Manual Jet Ventilation: A Safe Approach.","authors":"Sara Abu-Ghanem,&nbsp;James Cochran","doi":"10.1155/2023/5516988","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Surgical fires are known, preventable, and devastating complications of transoral microlaryngeal laser surgery. Several guidelines have recommended maintaining the fraction of inspired oxygen concentration (FiO<sub>2</sub>) at or below 30% for open delivery cases. We hereby present our experience utilizing an air/oxygen gas mixing device (blender) attached to a supraglottic manual jet ventilator during transoral laser microlaryngeal surgery in three cases to control oxygen levels.</p><p><strong>Methods: </strong>Retrospective chart review of three cases and literature review.</p><p><strong>Results: </strong>Three patients underwent microlaryngeal laser surgery and balloon dilation for the management of subglottic stenosis. All three patients were successfully ventilated throughout the procedures, and no major complications occurred intraoperatively. Two of three patients demonstrated symptomatic and clinical improvement at the first follow-up.</p><p><strong>Conclusions: </strong>This report demonstrates the successful use of an oxygen/air blender to reduce FiO<sub>2</sub> to fire-safe levels of less than 30% during laser surgery of the airway using jet ventilation.</p>","PeriodicalId":36504,"journal":{"name":"Case Reports in Anesthesiology","volume":"2023 ","pages":"5516988"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10495234/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Anesthesiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/5516988","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Surgical fires are known, preventable, and devastating complications of transoral microlaryngeal laser surgery. Several guidelines have recommended maintaining the fraction of inspired oxygen concentration (FiO2) at or below 30% for open delivery cases. We hereby present our experience utilizing an air/oxygen gas mixing device (blender) attached to a supraglottic manual jet ventilator during transoral laser microlaryngeal surgery in three cases to control oxygen levels.

Methods: Retrospective chart review of three cases and literature review.

Results: Three patients underwent microlaryngeal laser surgery and balloon dilation for the management of subglottic stenosis. All three patients were successfully ventilated throughout the procedures, and no major complications occurred intraoperatively. Two of three patients demonstrated symptomatic and clinical improvement at the first follow-up.

Conclusions: This report demonstrates the successful use of an oxygen/air blender to reduce FiO2 to fire-safe levels of less than 30% during laser surgery of the airway using jet ventilation.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经口激光显微手术合并声门上手动喷射通气时使用氧气/空气混合器:一种安全的方法。
背景:手术火灾是经口微喉激光手术已知的、可预防的、毁灭性的并发症。一些指南建议将开放分娩病例的吸入氧浓度(FiO2)保持在30%或以下。我们在此介绍我们在经口激光显微喉手术中使用空气/氧气混合装置(搅拌器)连接声门上手动喷射呼吸机来控制氧气水平的经验。方法:对3例病例进行回顾性图表复习和文献复习。结果:3例患者行喉激光微创手术及球囊扩张术治疗声门下狭窄。所有3例患者在整个手术过程中均成功通气,术中无重大并发症发生。三名患者中的两名在第一次随访时表现出症状和临床改善。结论:本报告展示了在气道激光手术中使用氧气/空气搅拌器成功地将FiO2降低到防火水平低于30%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Case Reports in Anesthesiology
Case Reports in Anesthesiology Medicine-Anesthesiology and Pain Medicine
CiteScore
1.40
自引率
0.00%
发文量
19
审稿时长
12 weeks
期刊最新文献
A Rare Case of Intraoperative Anaphylaxis Secondary to Central Venous Catheter Placement: A Case Report. Awake Thoracotomy in an Obese Case of Cardiac Tamponade: A Case Report. Uniportal Robotic-Assisted Tracheal Resection and Reconstruction Under Spontaneous Ventilation. Anesthetic Management and Considerations for Cesarean Delivery in a Patient With Cystic Fibrosis. Arrhythmia Induced by Positional Change Under General Anesthesia Related to Caudal Movement of the Peripherally Inserted Central Venous Catheter: A Case Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1