Accuracy of a Glycerol Dehydrogenase Assay for Ethylene Glycol Detection.

IF 2.5 4区 医学 Q3 TOXICOLOGY Journal of Medical Toxicology Pub Date : 2023-10-01 Epub Date: 2023-09-11 DOI:10.1007/s13181-023-00967-x
Ari B Filip, Christopher W Farnsworth, Michael E Mullins, Bridgit O Crews, Jeffrey A Kraut
{"title":"Accuracy of a Glycerol Dehydrogenase Assay for Ethylene Glycol Detection.","authors":"Ari B Filip,&nbsp;Christopher W Farnsworth,&nbsp;Michael E Mullins,&nbsp;Bridgit O Crews,&nbsp;Jeffrey A Kraut","doi":"10.1007/s13181-023-00967-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Ethylene glycol (EG) is a frequently considered toxicant in poisoned patients. Definitive diagnosis relies on gas chromatography (GC), but this is unavailable at most hospitals. A glycerol dehydrogenase (GDH)-based assay rapidly detects EG. A rapid turnaround time and wide availability of necessary instrumentation suggest this method could facilitate the rapid detection of EG.</p><p><strong>Methods: </strong>This is a prospective, observational analysis of banked, remnant serum samples submitted to the laboratory of a large, multi-hospital healthcare system. Samples were submitted over a 12-month period for the explicit purpose of testing for suspected EG ingestion. All samples underwent GC and the GDH-based assay.</p><p><strong>Results: </strong>Of the 118 analyzed samples, 88 had no EG detected by GC, and 30 were \"positive.\" At the manufacturer's threshold of 6 mg/dL EG, there was 100% (95%CI; 88.7-100) positive percent agreement (PPA) and 98% (92.1-99.6) negative percent agreement (NPA). Adjusted to a threshold of 9 mg/dL, both the PPA and NPA were 100%. Deming regression of the observed concentrations revealed a slope of 1.16 (1.01 to 1.32) and intercept of -5.3 (-8.9 to -1.7).</p><p><strong>Conclusions: </strong>The GDH assay provides a sensitive and specific method for the detection and quantification of EG that is comparable to a GC-based method. More widespread use of this rapid, inexpensive assay could improve the care of patients with suspected toxic alcohol exposure. Further study is needed to evaluate the test performance in real-time patient treatment decisions.</p>","PeriodicalId":16429,"journal":{"name":"Journal of Medical Toxicology","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10522546/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13181-023-00967-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Ethylene glycol (EG) is a frequently considered toxicant in poisoned patients. Definitive diagnosis relies on gas chromatography (GC), but this is unavailable at most hospitals. A glycerol dehydrogenase (GDH)-based assay rapidly detects EG. A rapid turnaround time and wide availability of necessary instrumentation suggest this method could facilitate the rapid detection of EG.

Methods: This is a prospective, observational analysis of banked, remnant serum samples submitted to the laboratory of a large, multi-hospital healthcare system. Samples were submitted over a 12-month period for the explicit purpose of testing for suspected EG ingestion. All samples underwent GC and the GDH-based assay.

Results: Of the 118 analyzed samples, 88 had no EG detected by GC, and 30 were "positive." At the manufacturer's threshold of 6 mg/dL EG, there was 100% (95%CI; 88.7-100) positive percent agreement (PPA) and 98% (92.1-99.6) negative percent agreement (NPA). Adjusted to a threshold of 9 mg/dL, both the PPA and NPA were 100%. Deming regression of the observed concentrations revealed a slope of 1.16 (1.01 to 1.32) and intercept of -5.3 (-8.9 to -1.7).

Conclusions: The GDH assay provides a sensitive and specific method for the detection and quantification of EG that is comparable to a GC-based method. More widespread use of this rapid, inexpensive assay could improve the care of patients with suspected toxic alcohol exposure. Further study is needed to evaluate the test performance in real-time patient treatment decisions.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
甘油脱氢酶测定法检测乙二醇的准确性。
引言:乙二醇(EG)是中毒患者经常考虑的毒物。最终诊断依赖于气相色谱(GC),但这在大多数医院是不可用的。基于甘油脱氢酶(GDH)的检测方法可以快速检测EG。快速的周转时间和广泛可用的必要仪器表明,该方法可以促进EG的快速检测。方法:这是对提交给大型多医院医疗保健系统实验室的库存残余血清样本的前瞻性、观察性分析。样本在12个月内提交,明确用于测试疑似乙二醇摄入。所有样品均进行GC和基于GDH的测定。结果:在118份分析样本中,88份GC未检测到EG,30份为“阳性”。在制造商规定的6 mg/dL EG阈值下,阳性百分比一致性(PPA)为100%(95%CI;88.7-100),阴性百分比一致性为98%(92.1-99.6)。调整到9 mg/dL的阈值,PPA和NPA均为100%。观察到的浓度的德明回归显示斜率为1.16(1.01至1.32),截距为-5.3(-8.9至-1.7)。结论:GDH测定为EG的检测和定量提供了一种灵敏和特异的方法,与基于GC的方法相当。更广泛地使用这种快速、廉价的检测方法可以改善疑似有毒酒精暴露患者的护理。需要进一步的研究来评估实时患者治疗决策中的测试性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.40
自引率
10.30%
发文量
46
期刊介绍: Journal of Medical Toxicology (JMT) is a peer-reviewed medical journal dedicated to advances in clinical toxicology, focusing on the diagnosis, management, and prevention of poisoning and other adverse health effects resulting from medications, chemicals, occupational and environmental substances, and biological hazards. As the official journal of the American College of Medical Toxicology (ACMT), JMT is managed by an editorial board of clinicians as well as scientists and thus publishes research that is relevant to medical toxicologists, emergency physicians, critical care specialists, pediatricians, pre-hospital providers, occupational physicians, substance abuse experts, veterinary toxicologists, and policy makers.       JMT articles generate considerable interest in the lay media, with 2016 JMT articles cited by various social media sites, the Boston Globe, and the Washington Post among others.     For questions or comments about the journal, please contact jmtinfo@acmt.net.    For questions or comments about the journal, please contact jmtinfo@acmt.net.
期刊最新文献
Investigating a Novel Two-Bag N-Acetylcysteine Regimen for Acetaminophen Toxicity. Intravenous Acetylcysteine: What Should Replace the Prescott "Three-Bag" Protocol? Comment on "Safety of Physostigmine for Pediatric Antimuscarinic Poisoning". In Response to Comment on "Safety of Physostigmine for Pediatric Antimuscarinic Poisoning". Pharmacobezoar Associated Prolonged Clinical Course in a Patient with Immediate Release Quetiapine Overdose.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1