{"title":"Development and Validation of a SPE-HPLC Method for Quantification of Rhein, Emodin, Chrysophanol and Physcion in Rhamnus petiolaris Boiss. & Balansa.","authors":"Pelin Köseoğlu Yılmaz, Ufuk Kolak","doi":"10.1093/chromsci/bmad053","DOIUrl":null,"url":null,"abstract":"<p><p>Anthraquinones exhibit a significant group of natural and synthetic quinone derivatives because of their biological activities and industrial applications. Rhamnaceae is one of the families known to contain different kinds of anthraquinones. In this study, it was aimed to quantify rhein, emodin, chrysophanol and physcion in fruits of Rhamnus petiolaris Boiss. & Balansa belonging to Rhamnaceae by solid phase extraction and high performance liquid chromatography with ultraviolet detection. The anthraquinones were separated using a C18 analytical column. Gradient elution was performed using a mobile phase consisted of 0.1% o-phosphoric acid solution and methanol. Analytes were detected at 254 nm. Calibration curves were prepared in the range of 0.25-5.00 μg/mL for rhein, chrysophanol, physcion, 1.00-50.00 μg/mL for emodin. Limits of detection and quantification were between 0.07-0.11 and 0.20-0.34 μg/mL, respectively. Relative standard deviations were ≤ 5.78% in repeatability and intermediate precision studies. Accuracy was determined as relative mean error (8.17-12.06%). Extraction was achieved by maceration with acetone and ethanol, followed by hydrophilic-lipophilic balance solid phase extraction. Recoveries were between 96.2 and 109.6%. The developed and validated method was successfully performed to quantify rhein, emodin, chrysophanol and physcion in R. petiolaris fruit extracts. Only physcion was not detected above limit of detection.</p>","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":" ","pages":"872-877"},"PeriodicalIF":1.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11530379/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmad053","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Anthraquinones exhibit a significant group of natural and synthetic quinone derivatives because of their biological activities and industrial applications. Rhamnaceae is one of the families known to contain different kinds of anthraquinones. In this study, it was aimed to quantify rhein, emodin, chrysophanol and physcion in fruits of Rhamnus petiolaris Boiss. & Balansa belonging to Rhamnaceae by solid phase extraction and high performance liquid chromatography with ultraviolet detection. The anthraquinones were separated using a C18 analytical column. Gradient elution was performed using a mobile phase consisted of 0.1% o-phosphoric acid solution and methanol. Analytes were detected at 254 nm. Calibration curves were prepared in the range of 0.25-5.00 μg/mL for rhein, chrysophanol, physcion, 1.00-50.00 μg/mL for emodin. Limits of detection and quantification were between 0.07-0.11 and 0.20-0.34 μg/mL, respectively. Relative standard deviations were ≤ 5.78% in repeatability and intermediate precision studies. Accuracy was determined as relative mean error (8.17-12.06%). Extraction was achieved by maceration with acetone and ethanol, followed by hydrophilic-lipophilic balance solid phase extraction. Recoveries were between 96.2 and 109.6%. The developed and validated method was successfully performed to quantify rhein, emodin, chrysophanol and physcion in R. petiolaris fruit extracts. Only physcion was not detected above limit of detection.
期刊介绍:
The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.