Comparison of Different Cleaning Procedures for Decontaminating Zirconium Oxide Surface After Polishing.

IF 2.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Prosthodontics Pub Date : 2023-11-01 DOI:10.11607/ijp.6896
Evelina Gineviciute, Jonas Alkimavicius, Rolandas Andrijauskas, Danas Sakalauskas, Laura Linkeviciene
{"title":"Comparison of Different Cleaning Procedures for Decontaminating Zirconium Oxide Surface After Polishing.","authors":"Evelina Gineviciute,&nbsp;Jonas Alkimavicius,&nbsp;Rolandas Andrijauskas,&nbsp;Danas Sakalauskas,&nbsp;Laura Linkeviciene","doi":"10.11607/ijp.6896","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the efficacy of cleaning protocols for the decontamination of organic compounds from polished zirconium oxide samples.</p><p><strong>Materials and methods: </strong>A total of 24 rectangular plate specimens were sintered from zirconium oxide. All samples were polished with commercially available polishers (coarse, fine, and superfine) and polishing paste. During the first step of the protocol, all specimens were cleaned with steam. Samples were then randomly assigned to one of three groups (n = 8 each): A, B, or C. In group A, no additional cleaning was performed, while specimens in group B underwent ultrasonic cleaning in distilled water. Group C specimens were cleaned in an ultrasonic bath with a special detergent solution. After washing, samples were subjected to energy-dispersive x-ray spectroscopy (EDX) and scanning electron microscopy (SEM) examination. In order to detect organic materials, the level of carbon atoms was measured.</p><p><strong>Results: </strong>EDX analysis revealed that samples in group A had the highest percent of carbon atoms (9.57 ± 3.67) on the surface compared to other cleaning protocols. Following the Group B cleaning protocol resulted in lower carbon levels (4.73 ± 3.56), but this difference was not significant compared to group A (P = .439). None of the specimens in group C had detectable carbon atoms (0), which implies that all wax molecules were removed (P < .05).</p><p><strong>Conclusion: </strong>Total decontamination of organic compounds from a polished zirconium surface can be expected only following the C cleaning protocol; therefore, it is advised to employ an ultrasonic bath with detergent solution for cleaning procedures of zirconium abutments before delivery. Int J Prosthodont 2023;36:588-594.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"588-594"},"PeriodicalIF":2.1000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.6896","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: To evaluate the efficacy of cleaning protocols for the decontamination of organic compounds from polished zirconium oxide samples.

Materials and methods: A total of 24 rectangular plate specimens were sintered from zirconium oxide. All samples were polished with commercially available polishers (coarse, fine, and superfine) and polishing paste. During the first step of the protocol, all specimens were cleaned with steam. Samples were then randomly assigned to one of three groups (n = 8 each): A, B, or C. In group A, no additional cleaning was performed, while specimens in group B underwent ultrasonic cleaning in distilled water. Group C specimens were cleaned in an ultrasonic bath with a special detergent solution. After washing, samples were subjected to energy-dispersive x-ray spectroscopy (EDX) and scanning electron microscopy (SEM) examination. In order to detect organic materials, the level of carbon atoms was measured.

Results: EDX analysis revealed that samples in group A had the highest percent of carbon atoms (9.57 ± 3.67) on the surface compared to other cleaning protocols. Following the Group B cleaning protocol resulted in lower carbon levels (4.73 ± 3.56), but this difference was not significant compared to group A (P = .439). None of the specimens in group C had detectable carbon atoms (0), which implies that all wax molecules were removed (P < .05).

Conclusion: Total decontamination of organic compounds from a polished zirconium surface can be expected only following the C cleaning protocol; therefore, it is advised to employ an ultrasonic bath with detergent solution for cleaning procedures of zirconium abutments before delivery. Int J Prosthodont 2023;36:588-594.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
抛光后氧化锆表面不同清洗程序的比较。
目的:评估清洁方案对抛光氧化锆样品中有机化合物的净化效果。材料和方法:用氧化锆烧结了24块矩形板试样。所有样品都用市售抛光剂(粗、细和超细)和抛光膏进行抛光。在方案的第一步中,所有样本都用蒸汽清洗。然后将样品随机分配到三组中的一组(每组n=8):A、B或C。在A组中,不进行额外的清洁,而B组的样品在蒸馏水中进行超声波清洁。C组标本在超声波浴中用特殊洗涤剂溶液清洗。洗涤后,对样品进行能量色散x射线光谱(EDX)和扫描电子显微镜(SEM)检查。为了检测有机物质,测量了碳原子的含量。结果:EDX分析显示,与其他清洁方案相比,A组样品表面的碳原子百分比最高(9.57±3.67)。按照B组清洁方案,碳含量较低(4.73±3.56),但与A组相比,这一差异并不显著(P=.439)。C组中没有一个样品具有可检测的碳原子(0),这意味着所有的蜡分子都被去除了(P<.05)。结论:只有遵循C清洁方案,才能预期抛光锆表面有机化合物的完全去污;因此,建议在交付前使用带有洗涤剂溶液的超声波浴来清洁锆基牙。Int J Prostodont 2023;36:588-594。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Prosthodontics
International Journal of Prosthodontics 医学-牙科与口腔外科
CiteScore
3.20
自引率
4.30%
发文量
82
审稿时长
6-12 weeks
期刊介绍: Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP) Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.
期刊最新文献
A Comparison of Abutment Screw Loosening in 24-Degree Angulation-Correcting and Straight Implants: An In Vitro Study. Analysis of Topography, Flexural Strength, and Microstructure of a Lithium Disilicate Glass- Ceramic after Surface Finishing. Aging and Fracture Resistance of Screw-Retained Implant-Supported Molar Crowns Fabricated from Lithium Disilicate Containing Virgilite. Comparison Between Interocclusal Registration Using Silicone Bite Registration Material and Intraoral Scanner on Clenching Strength. Satisfaction with Labial Reinforcement of Custom-Made Mouthguards Among a Cohort of Rugby Union Players: A Randomized Crossover Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1