Accuracy and Efficiency of Digitally Fabricated All-Ceramic Crowns from Conventional Impressions and Intraoral Scans: A Single-Blind Clinical Randomized Controlled Trial.

IF 2.1 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Prosthodontics Pub Date : 2024-02-21 DOI:10.11607/ijp.8143
Xinggang Liu, Kun Feng, Ling Dong, Lixia Liu, Lin Ni, Dongxiang Zheng
{"title":"Accuracy and Efficiency of Digitally Fabricated All-Ceramic Crowns from Conventional Impressions and Intraoral Scans: A Single-Blind Clinical Randomized Controlled Trial.","authors":"Xinggang Liu, Kun Feng, Ling Dong, Lixia Liu, Lin Ni, Dongxiang Zheng","doi":"10.11607/ijp.8143","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the accuracy of intraoral scanners by comparing the marginal fit of 70 all-ceramic crowns fabricated from both conventional impressions and intraoral scans.</p><p><strong>Materials and methods: </strong>A total of 70 posterior teeth requiring single-crown restorations randomly underwent either intraoral scanning or conventional impression-taking, followed by laboratory scanning of the casts in a parallel-group randomized controlled trial (RCT). Subsequently, 70 monolithic all-ceramic crowns were CAD/CAM fabricated; only the impression technique differed. The marginal fit, internal fit, adjustment time required for insertion and occlusal contacts, and visual analog scale (VAS) scores assessing dentists' satisfaction with the crowns were clinically evaluated by a calibrated examiner who was blinded to the groups. Data were analyzed using independent samples t test and likelihood-ratio test or Fisher exact test. All tests were performed with α = .05.</p><p><strong>Results: </strong>The mean marginal fit with intraoral scanning (57.94 Å} 22.51 μm) was better than with diagnostic cast scanning (82.98 Å} 21.72 μm). The difference was statistically significant (P = .000). The differences in internal fit, adjustment time for crown insertion and occlusal contacts, and VAS scores were also significant, and the secondary outcomes were in favor of intraoral scanning.</p><p><strong>Conclusions: </strong>Within the limitations of this clinical trial, CAD/CAM-fabricated single-tooth restorations in the posterior region produced with an intraoral scanning technique using TRIOS were found to be a more accurate, efficient alternative to restorations based on conventional impressions in combination with the laboratory scanning technique.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":"8-15"},"PeriodicalIF":2.1000,"publicationDate":"2024-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.8143","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the accuracy of intraoral scanners by comparing the marginal fit of 70 all-ceramic crowns fabricated from both conventional impressions and intraoral scans.

Materials and methods: A total of 70 posterior teeth requiring single-crown restorations randomly underwent either intraoral scanning or conventional impression-taking, followed by laboratory scanning of the casts in a parallel-group randomized controlled trial (RCT). Subsequently, 70 monolithic all-ceramic crowns were CAD/CAM fabricated; only the impression technique differed. The marginal fit, internal fit, adjustment time required for insertion and occlusal contacts, and visual analog scale (VAS) scores assessing dentists' satisfaction with the crowns were clinically evaluated by a calibrated examiner who was blinded to the groups. Data were analyzed using independent samples t test and likelihood-ratio test or Fisher exact test. All tests were performed with α = .05.

Results: The mean marginal fit with intraoral scanning (57.94 Å} 22.51 μm) was better than with diagnostic cast scanning (82.98 Å} 21.72 μm). The difference was statistically significant (P = .000). The differences in internal fit, adjustment time for crown insertion and occlusal contacts, and VAS scores were also significant, and the secondary outcomes were in favor of intraoral scanning.

Conclusions: Within the limitations of this clinical trial, CAD/CAM-fabricated single-tooth restorations in the posterior region produced with an intraoral scanning technique using TRIOS were found to be a more accurate, efficient alternative to restorations based on conventional impressions in combination with the laboratory scanning technique.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根据传统印模和口内扫描数字化制作全瓷牙冠的准确性和效率:单盲临床随机对照试验。
目的:通过比较根据传统印模和口内扫描制作的 70 个全瓷牙冠的边缘密合度,评估口内扫描仪的准确性:共有 70 颗需要单冠修复的后牙随机接受了口内扫描或传统印模取模,然后在平行组 RCT 中对铸模进行实验室扫描。随后,采用 CAD/CAM 技术制作了 70 个单体全瓷冠;只有印模技术有所不同。边缘密合度、内部密合度、插入和咬合接触所需的调整时间,以及评估牙医对所有牙冠满意度的视觉模拟量表(VAS)评分,均由盲法校准检查员进行临床评估。数据分析采用独立样本 t 检验和似然比检验或费雪精确检验。所有检验均以α = .05进行:口内扫描的平均边缘密合度(57.94 ± 22.51 μm)优于诊断性石膏扫描(82.98 ± 21.72 μm)。差异具有统计学意义(P = .000)。在内侧密合度、牙冠插入和咬合接触的调整时间以及VAS评分方面的差异也很显著,次要结果有利于口内扫描:结论:在本临床试验的限制条件下,使用 TRIOS 口内扫描技术制作的后牙区单牙 CAD/CAM 修复体比基于传统印模结合技工室扫描技术制作的修复体更精确、更高效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Prosthodontics
International Journal of Prosthodontics 医学-牙科与口腔外科
CiteScore
3.20
自引率
4.30%
发文量
82
审稿时长
6-12 weeks
期刊介绍: Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP) Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.
期刊最新文献
A Comparison of Abutment Screw Loosening in 24-Degree Angulation-Correcting and Straight Implants: An In Vitro Study. Analysis of Topography, Flexural Strength, and Microstructure of a Lithium Disilicate Glass- Ceramic after Surface Finishing. Aging and Fracture Resistance of Screw-Retained Implant-Supported Molar Crowns Fabricated from Lithium Disilicate Containing Virgilite. Comparison Between Interocclusal Registration Using Silicone Bite Registration Material and Intraoral Scanner on Clenching Strength. Satisfaction with Labial Reinforcement of Custom-Made Mouthguards Among a Cohort of Rugby Union Players: A Randomized Crossover Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1