Correlation of Sonographic Parameters with Renal Function in Patients with Newly Diagnosed Chronic Kidney Disease.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Ultrasonography Pub Date : 2022-10-01 DOI:10.15557/jou.2022.0036
Aborishi Garg, Anupam Jhobta, Sumala Kapila, Devesha Rathour
{"title":"Correlation of Sonographic Parameters with Renal Function in Patients with Newly Diagnosed Chronic Kidney Disease.","authors":"Aborishi Garg,&nbsp;Anupam Jhobta,&nbsp;Sumala Kapila,&nbsp;Devesha Rathour","doi":"10.15557/jou.2022.0036","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To correlate sonographic renal parameters (mean renal cortical thickness, length and volume) with renal functions in patients with newly diagnosed chronic kidney disease. To predict the best renal parameter correlating with renal functions in patients with newly diagnosed chronic kidney disease.</p><p><strong>Material and methods: </strong>A hospital-based prospective cross-sectional study was conducted in the Department of Radiodiagnosis, Indira Gandhi Medical College and Hospital, Shimla, in 78 adults with newly diagnosed chronic kidney disease visiting the hospital from December 2019 to November 2020.</p><p><strong>Results: </strong>A statistically significant positive correlation was found between eGFR and mean renal length, mean renal cortical thickness, and mean renal volume (<i>p</i> <0.001).The strongest correlation was shown between mean renal volume and eGFR (r = 0.90, r<sup>2</sup> = 0.82; <i>p</i>-value <0.001).</p><p><strong>Conclusions: </strong>Renal volume and cortical thickness should be considered along with traditional renal parameters.</p>","PeriodicalId":45612,"journal":{"name":"Journal of Ultrasonography","volume":"22 91","pages":"e216-e221"},"PeriodicalIF":1.3000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/14/21/jou-22-e216.PMC9714278.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasonography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15557/jou.2022.0036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: To correlate sonographic renal parameters (mean renal cortical thickness, length and volume) with renal functions in patients with newly diagnosed chronic kidney disease. To predict the best renal parameter correlating with renal functions in patients with newly diagnosed chronic kidney disease.

Material and methods: A hospital-based prospective cross-sectional study was conducted in the Department of Radiodiagnosis, Indira Gandhi Medical College and Hospital, Shimla, in 78 adults with newly diagnosed chronic kidney disease visiting the hospital from December 2019 to November 2020.

Results: A statistically significant positive correlation was found between eGFR and mean renal length, mean renal cortical thickness, and mean renal volume (p <0.001).The strongest correlation was shown between mean renal volume and eGFR (r = 0.90, r2 = 0.82; p-value <0.001).

Conclusions: Renal volume and cortical thickness should be considered along with traditional renal parameters.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新诊断慢性肾病患者超声参数与肾功能的相关性
目的:探讨新诊断慢性肾病患者超声肾参数(平均肾皮质厚度、长度和体积)与肾功能的关系。目的:预测新诊断慢性肾病患者与肾功能相关的最佳肾脏参数。材料和方法:在西姆拉英迪拉甘地医学院和医院放射诊断科对2019年12月至2020年11月期间就诊的78名新诊断为慢性肾病的成年人进行了一项基于医院的前瞻性横断面研究。结果:eGFR与平均肾长度、平均肾皮质厚度、平均肾体积呈正相关(p 2 = 0.82;结论:肾体积和肾皮质厚度应与传统的肾脏参数一起考虑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Ultrasonography
Journal of Ultrasonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.30
自引率
0.00%
发文量
58
审稿时长
20 weeks
期刊最新文献
Imaging methods in monitoring gout - a pictorial essay. Measures of acromiohumeral distance with wireless ultrasound machine in subacromial impingement syndrome: an inter-machine reliability study. The atlantomastoid: a muscle variant relevant to point-of-care ultrasound? Ultrasonography in the diagnosis of pediatric distal forearm fracture: a systematic review. Uterine vascular abnormalities linked to pregnancy complications: color and power Doppler-assisted transvaginal ultrasound evaluation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1