Brian C Lynch, David R Swanson, William A Marmor, Bryan Gibb, David E Komatsu, Edward D Wang
{"title":"The Relationship between Bacterial Load and Initial Run Time of a Surgical Helmet.","authors":"Brian C Lynch, David R Swanson, William A Marmor, Bryan Gibb, David E Komatsu, Edward D Wang","doi":"10.1177/24715492221142688","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Periprosthetic joint infection (PJI) is a complication of arthroplasty surgery with significant morbidity and mortality. Surgical helmets are a possible source of infection. Pre-existing dust and microorganisms on its surface may be blown into the surgical field by the helmet ventilation system.</p><p><strong>Methods: </strong>Twenty surgical helmets at our institution were assessed through microscopy and polymerase chain reaction testing. Helmets were arranged with agar plates under the front and rear outflow vents. Helmets ran while plates were exchanged at different time points. Bacterial growth was assessed via colony counts and correlated with fan operating time. Gram staining and 16S sequencing were performed to identify bacterial species.</p><p><strong>Results: </strong>The primary microbiological contaminate identified was Burkholderia. There was an inverse relationship between colony formation and fan operating time. The highest number of colonies was found within the first minute of fan operating time. There was a significant decrease in the number of colonies formed from the zero-minute to the three (27 vs 5; <i>P</i> = <.01), four (27 vs 3; <i>P</i> = <.01), and five-minute (27 vs 4; <i>P</i> = <.01) time points for the front outflow plates. A significant difference was also observed between the one-minute and four-minute time points (<i>P</i> = .046).</p><p><strong>Conclusion: </strong>We observed an inverse relationship between bacterial spread helmet fan operation time, which may correlate with dispersion of pre-existing contaminates. To decrease contamination risk, we recommend that helmets are run for at least 3 min prior to entering the operating room.</p>","PeriodicalId":73942,"journal":{"name":"Journal of shoulder and elbow arthroplasty","volume":"6 ","pages":"24715492221142688"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/07/8d/10.1177_24715492221142688.PMC9720822.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of shoulder and elbow arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/24715492221142688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Background: Periprosthetic joint infection (PJI) is a complication of arthroplasty surgery with significant morbidity and mortality. Surgical helmets are a possible source of infection. Pre-existing dust and microorganisms on its surface may be blown into the surgical field by the helmet ventilation system.
Methods: Twenty surgical helmets at our institution were assessed through microscopy and polymerase chain reaction testing. Helmets were arranged with agar plates under the front and rear outflow vents. Helmets ran while plates were exchanged at different time points. Bacterial growth was assessed via colony counts and correlated with fan operating time. Gram staining and 16S sequencing were performed to identify bacterial species.
Results: The primary microbiological contaminate identified was Burkholderia. There was an inverse relationship between colony formation and fan operating time. The highest number of colonies was found within the first minute of fan operating time. There was a significant decrease in the number of colonies formed from the zero-minute to the three (27 vs 5; P = <.01), four (27 vs 3; P = <.01), and five-minute (27 vs 4; P = <.01) time points for the front outflow plates. A significant difference was also observed between the one-minute and four-minute time points (P = .046).
Conclusion: We observed an inverse relationship between bacterial spread helmet fan operation time, which may correlate with dispersion of pre-existing contaminates. To decrease contamination risk, we recommend that helmets are run for at least 3 min prior to entering the operating room.
背景:假体周围关节感染(PJI)是关节置换术的并发症,具有很高的发病率和死亡率。手术头盔是一个可能的感染源。其表面存在的灰尘和微生物可能被头盔通风系统吹入手术场。方法:通过镜检和聚合酶链反应检测对我院20个外科头盔进行评估。头盔前后出风口下设置琼脂板。在不同的时间点交换车牌时,头盔在奔跑。通过菌落计数评估细菌生长,并与风扇操作时间相关。革兰氏染色和16S测序鉴定细菌种类。结果:鉴定出的主要微生物污染物为伯克霍尔德菌。菌落形成与风机运行时间呈反比关系。在风扇工作时间的第一分钟内,菌落数量最多。从0分钟到3分钟,形成的菌落数量显著减少(27 vs 5;p = p = p = p = 0.046)。结论:我们观察到细菌传播与头盔风扇操作时间成反比关系,这可能与预先存在的污染物的分散有关。为了降低污染风险,我们建议在进入手术室之前,头盔至少运行3分钟。