Isadora Ames Silva, Gabriel Barcelos Só, Theodoro Weissheimer, Aline Mendes, Lina Naomi Hashizume, Marcus Vinícius Reis Só, Ricardo Abreu Da Rosa
{"title":"Does the ultrasonic activation of calcium silicate-based sealers affect their physicochemical properties?","authors":"Isadora Ames Silva, Gabriel Barcelos Só, Theodoro Weissheimer, Aline Mendes, Lina Naomi Hashizume, Marcus Vinícius Reis Só, Ricardo Abreu Da Rosa","doi":"10.1590/0103-6440202205100","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to evaluate the influence of ultrasonic activation (UA) on the physicochemical properties of hydraulic calcium silicate-based sealers. Nine experimental conditions were created based on the hydraulic calcium silicate-based sealers (Bio-C Sealer, Sealer Plus BC and Bio Root RCS) and the ultrasonic activation (no activation [NA], 10 seconds, and 20 seconds). Then the experimental groups were BC-NA, BC-10, BC-20, SPBC-NA, SPBC-10, SPBC-20, BR-NA, BR-10, and BR-20. Activation was performed with an ultrasonic insert 20/.01. The mold for the physicochemical analysis was filled and evaluated according to the ANSI/ADA specification nº. 57: initial and final setting time, flow, radiopacity and solubility. Tests were also performed to evaluate pH and calcium ion release with experimental periods of 1, 24, 72, and 168 hours with a pH meter and colorimetric spectrophotometer. Data were analyzed by one-way analysis of variance and post-hoc Tukey tests. The significance level was set at 5%. The time of UA progressively delayed the initial setting time for all hydraulic calcium silicate-based sealers (p < 0.05). Twenty seconds of UA increased the mean flow values of Sealer Plus BC and Bio-C Sealer compared to NA (p < 0.05). UA did not influence the radiopacity and solubility of the tested sealers (p > 0.05). UA for 20 seconds enhanced the pH levels and the calcium ion release of Sealer Plus BC and Bio-C Sealer at 168h (p < 0.05). UA for twenty seconds interferes with some physicochemical properties of hydraulic calcium silicate-based sealers.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"33 6","pages":"20-27"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9733370/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian dental journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0103-6440202205100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1
Abstract
This study aimed to evaluate the influence of ultrasonic activation (UA) on the physicochemical properties of hydraulic calcium silicate-based sealers. Nine experimental conditions were created based on the hydraulic calcium silicate-based sealers (Bio-C Sealer, Sealer Plus BC and Bio Root RCS) and the ultrasonic activation (no activation [NA], 10 seconds, and 20 seconds). Then the experimental groups were BC-NA, BC-10, BC-20, SPBC-NA, SPBC-10, SPBC-20, BR-NA, BR-10, and BR-20. Activation was performed with an ultrasonic insert 20/.01. The mold for the physicochemical analysis was filled and evaluated according to the ANSI/ADA specification nº. 57: initial and final setting time, flow, radiopacity and solubility. Tests were also performed to evaluate pH and calcium ion release with experimental periods of 1, 24, 72, and 168 hours with a pH meter and colorimetric spectrophotometer. Data were analyzed by one-way analysis of variance and post-hoc Tukey tests. The significance level was set at 5%. The time of UA progressively delayed the initial setting time for all hydraulic calcium silicate-based sealers (p < 0.05). Twenty seconds of UA increased the mean flow values of Sealer Plus BC and Bio-C Sealer compared to NA (p < 0.05). UA did not influence the radiopacity and solubility of the tested sealers (p > 0.05). UA for 20 seconds enhanced the pH levels and the calcium ion release of Sealer Plus BC and Bio-C Sealer at 168h (p < 0.05). UA for twenty seconds interferes with some physicochemical properties of hydraulic calcium silicate-based sealers.
期刊介绍:
Brazilian Dental Journal, publishes Full-Length Papers, Short Communications and Case Reports, dealing with dentistry or related disciplines and edited six times a year.