{"title":"Demography, indications and outcome of descemet stripping automated endothelial keratoplasty in Nepal.","authors":"Leena Bajracharya,&nbsp;Leesha Shrestha Joshi,&nbsp;Rachana Singh Rana,&nbsp;Reeta Gurung","doi":"10.3126/nepjoph.v14i2.40248","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Descemet stripping automated endothelial keratoplasty (DSAEK) is performed for corneal endothelial pathology. It had gained popularity over penetrating keratoplasty (PK) because of better outcome.</p><p><strong>Methods: </strong>Retrospective data was collected from records of patients who underwent DSAEK from 2005 to 2019. Demography, indications and post-operative complications of DSAEK were analyzed. Outcome was measured in terms of graft clarity and vision.</p><p><strong>Results: </strong>93 eyes of 86 patients had undergone DSAEK in the study period of 15 years. Average age of the patients was 61.0 years. 55.9% were female. The common indications for DSAEK were cataract surgery related bullous keratopathy (n=47, 50.5%), Fuchs dystrophy (n=22, 23.6%) and failed graft (n=11, 11.8%). 8.6% of surgeries had graft detachment and 5.3% had pupillary block in the early post-operative period. Outcome analysis was done for cases (n=80) which had follow-up duration of at least 2 months (range: 2 months to 11 years; average: 28.5 months).Endothelial rejection occurred in 8 cases (10.0%), 5 of which regained graft clarity after treatment. At the last follow-up visit, 23.8% (n=19) of grafts had failed, which was mostly due to endothelial failure (n=16); 3 grafts failed due to infective keratitis. 42.5% (n=34) acquired best corrected vision of 6/18 or better. The average astigmatic error was 1.6 Diopter Cylinder by refraction.</p><p><strong>Conclusion: </strong>DSAEK showed good outcome with our results comparable to other studies. It had replaced traditional PK in our institute for endothelial dysfunction. Surgeons in the country should be encouraged and trained to do the procedure.</p>","PeriodicalId":44759,"journal":{"name":"Nepalese Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nepalese Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/nepjoph.v14i2.40248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Descemet stripping automated endothelial keratoplasty (DSAEK) is performed for corneal endothelial pathology. It had gained popularity over penetrating keratoplasty (PK) because of better outcome.

Methods: Retrospective data was collected from records of patients who underwent DSAEK from 2005 to 2019. Demography, indications and post-operative complications of DSAEK were analyzed. Outcome was measured in terms of graft clarity and vision.

Results: 93 eyes of 86 patients had undergone DSAEK in the study period of 15 years. Average age of the patients was 61.0 years. 55.9% were female. The common indications for DSAEK were cataract surgery related bullous keratopathy (n=47, 50.5%), Fuchs dystrophy (n=22, 23.6%) and failed graft (n=11, 11.8%). 8.6% of surgeries had graft detachment and 5.3% had pupillary block in the early post-operative period. Outcome analysis was done for cases (n=80) which had follow-up duration of at least 2 months (range: 2 months to 11 years; average: 28.5 months).Endothelial rejection occurred in 8 cases (10.0%), 5 of which regained graft clarity after treatment. At the last follow-up visit, 23.8% (n=19) of grafts had failed, which was mostly due to endothelial failure (n=16); 3 grafts failed due to infective keratitis. 42.5% (n=34) acquired best corrected vision of 6/18 or better. The average astigmatic error was 1.6 Diopter Cylinder by refraction.

Conclusion: DSAEK showed good outcome with our results comparable to other studies. It had replaced traditional PK in our institute for endothelial dysfunction. Surgeons in the country should be encouraged and trained to do the procedure.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人口统计学,指征和结果的网膜剥离自动内皮角膜移植术在尼泊尔。
背景:Descemet剥离自动内皮角膜移植术(DSAEK)用于角膜内皮病理。由于效果较好,它已比穿透性角膜移植术(PK)更受欢迎。方法:收集2005 - 2019年DSAEK患者的回顾性资料。分析DSAEK的人口统计学、适应证及术后并发症。结果是根据移植物的清晰度和视力来衡量的。结果:在15年的研究期间,86例患者93只眼接受了DSAEK手术。患者平均年龄61.0岁。55.9%为女性。DSAEK的常见适应症为白内障手术相关大疱性角膜病变(n=47, 50.5%)、Fuchs营养不良(n=22, 23.6%)和移植失败(n=11, 11.8%)。8.6%的患者术后早期出现移植物脱离,5.3%的患者术后早期出现瞳孔阻滞。对随访时间至少2个月的病例(n=80)进行结果分析(范围:2个月至11年;平均:28.5个月)。8例(10.0%)发生内皮排斥反应,其中5例经治疗后移植物恢复透明。最后一次随访时,23.8% (n=19)的移植物失败,主要是由于内皮细胞衰竭(n=16);3例因感染性角膜炎导致移植失败。42.5% (n=34)获得6/18或更高的最佳矫正视力。平均像散误差为1.6屈光度圆柱。结论:DSAEK显示了良好的结果,我们的结果与其他研究相当。它已经取代了我们研究所治疗内皮功能障碍的传统PK。应该鼓励和培训该国的外科医生进行这种手术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
27
审稿时长
12 weeks
期刊最新文献
Ocular Findings among the Patients of Renal Transplantation Radius-Maumenee Syndrome, A Rare Entity: A Case Report Developing Artificial Intelligence Model for Prediction of Diabetic Retinopathy and Delivering in a real-world Local Context: BP Eye Foundation’s Perspective A Case of Full Thickness Parafoveal Hole Associated with Chorio-Retinal Atrophy Hyperostotic Sphenoid Wing Meningioma with Proptosis: A Rare Case Report with Literature Review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1