Luca Filippi, Viviana Frantellizzi, Giuseppe De Vincentis, Orazio Schillaci
{"title":"The new bone WB-SPECT/CT: hybrid, from head-to-toe and digital! Is it worth the effort?","authors":"Luca Filippi, Viviana Frantellizzi, Giuseppe De Vincentis, Orazio Schillaci","doi":"10.1080/17434440.2023.2252743","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>A bone scan (BS) plays a pivotal role in many oncological and non-oncological conditions. The planar BS is characterized by high sensitivity but low specificity. With respect to planar imaging, the implementation of single-photon emission computed tomography (SPECT) has allowed increased image contrast and more accurate tracer localization.</p><p><strong>Areas covered: </strong>Recent technological innovations in the field of BS are treated, with a particular focus on multi-field-of-view devices allowing to cover the entire scan length with a 3D acquisition (WB-SPECT/CT). In addition, the applications of cadmium zinc telluride/CzT detectors capable of converting gamma photons directly into electrical impulses (i.e. 'digital SPECT') are discussed.</p><p><strong>Expert opinion: </strong>Initial clinical experiences indicate that WB-SPECT/CT is characterized by higher sensitivity, diagnostic accuracy, and increased confidence in image interpretation with respect to the 'old-fashioned' BS (planar images with or without a single field-of-view SPECT). Furthermore, CzT-based detectors, thanks to their superior sensitivity, might be helpful to implement fast acquisition protocols. Further studies are needed to better define the clinical impact of bone CzT WB-SPECT/CT on patients' management and outcome, as well as its cost-benefit ratio.</p>","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":" ","pages":"791-795"},"PeriodicalIF":2.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Medical Devices","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2252743","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/29 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1
Abstract
Introduction: A bone scan (BS) plays a pivotal role in many oncological and non-oncological conditions. The planar BS is characterized by high sensitivity but low specificity. With respect to planar imaging, the implementation of single-photon emission computed tomography (SPECT) has allowed increased image contrast and more accurate tracer localization.
Areas covered: Recent technological innovations in the field of BS are treated, with a particular focus on multi-field-of-view devices allowing to cover the entire scan length with a 3D acquisition (WB-SPECT/CT). In addition, the applications of cadmium zinc telluride/CzT detectors capable of converting gamma photons directly into electrical impulses (i.e. 'digital SPECT') are discussed.
Expert opinion: Initial clinical experiences indicate that WB-SPECT/CT is characterized by higher sensitivity, diagnostic accuracy, and increased confidence in image interpretation with respect to the 'old-fashioned' BS (planar images with or without a single field-of-view SPECT). Furthermore, CzT-based detectors, thanks to their superior sensitivity, might be helpful to implement fast acquisition protocols. Further studies are needed to better define the clinical impact of bone CzT WB-SPECT/CT on patients' management and outcome, as well as its cost-benefit ratio.
期刊介绍:
The journal serves the device research community by providing a comprehensive body of high-quality information from leading experts, all subject to rigorous peer review. The Expert Review format is specially structured to optimize the value of the information to reader. Comprehensive coverage by each author in a key area of research or clinical practice is augmented by the following sections:
Expert commentary - a personal view on the most effective or promising strategies
Five-year view - a clear perspective of future prospects within a realistic timescale
Key issues - an executive summary cutting to the author''s most critical points
In addition to the Review program, each issue also features Medical Device Profiles - objective assessments of specific devices in development or clinical use to help inform clinical practice. There are also Perspectives - overviews highlighting areas of current debate and controversy, together with reports from the conference scene and invited Editorials.