Sung Ho Moon, Daeseok Oh, Myoung Jin Ko, Ji Yeon Kwon, Young Gyun Choi, Sun Young Kim, Sehun Lim
{"title":"Thenar Compartment Syndrome Related to Tightened Radial Arterial Line During Robotic Laparoscopic Surgery: A Case Report.","authors":"Sung Ho Moon, Daeseok Oh, Myoung Jin Ko, Ji Yeon Kwon, Young Gyun Choi, Sun Young Kim, Sehun Lim","doi":"10.1213/XAA.0000000000001642","DOIUrl":null,"url":null,"abstract":"<p><p>We present a 54-year-old man who developed an unexpected thenar space compartment syndrome after robotic laparoscopic surgery, which was caused when the radial arterial pressure tubing was pulled too tightly around the base of the thumb while changing the surgical position. A conventional method of securing the tubing by looping it around the thumb appeared to be the primary cause. This complication went unnoticed during the surgery because the arm was tucked out of sight; there were no remarkable findings on monitoring. This case highlights the risks of looping tubing around the thumb, especially if continual inspection is not possible.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":"16 12","pages":"e01642"},"PeriodicalIF":0.5000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"A&A Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1213/XAA.0000000000001642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We present a 54-year-old man who developed an unexpected thenar space compartment syndrome after robotic laparoscopic surgery, which was caused when the radial arterial pressure tubing was pulled too tightly around the base of the thumb while changing the surgical position. A conventional method of securing the tubing by looping it around the thumb appeared to be the primary cause. This complication went unnoticed during the surgery because the arm was tucked out of sight; there were no remarkable findings on monitoring. This case highlights the risks of looping tubing around the thumb, especially if continual inspection is not possible.
期刊介绍:
A & A Case Reports, our new online journal publishing Case Reports, related Editorial Commentary, and Correspondence. Anesthesia & Analgesia 1 and Anesthesiology 2 recently announced that they were suspending publication of Case Reports. One reason is that Case Reports typically reduce the Impact Factor of a journal because they are rarely cited. Regardless of the merits of Impact Factor as a metric of journal worth, journals and their editors necessarily consider Impact Factor in strategic planning. At the same time, Case Reports are appreciated by readers for describing “real life” management of difficult or unusual cases not often encountered by practitioners. In a recent issue of Anesthesia & Analgesia, Steven Shafer1 identified many Case Reports whose publication launched productive careers dedicated to solving the puzzle posed by an unusual observation in a single patient.