{"title":"Reproducibility of each retinal layer thickness measurement in epiretinal membrane patients with ectopic inner foveal layers.","authors":"Il Jung,&nbsp;Yong-Jin Na,&nbsp;Sung-Chul Lee,&nbsp;Min-Woo Lee","doi":"10.1186/s40662-022-00321-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To identify the reliability of each retinal layer thickness measurement in epiretinal membrane (ERM) patients with ectopic inner foveal layers (EIFLs).</p><p><strong>Methods: </strong>Subjects were divided into two groups: ERM patients with EIFLs (Group 1) and without EIFLs (Group 2). The retinal layer thickness was measured twice, and intraclass correlation coefficient (ICC) and coefficient of variation (CV) values were calculated.</p><p><strong>Results: </strong>In Group 1, the CVs of the nerve fiber layer (NFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), and outer nuclear layer (ONL) were 22.39%, 13.12%, 13.37%, 13.21%, 15.09%, and 11.94%, while the ICCs were 0.431, 0.550, 0.440, 0.286, 0.279, and 0.503, respectively. In Group 2, the CVs were 18.20%, 10.59%, 10.65%, 13.27%, 14.75%, and 10.37%, while the ICCs were 0.788, 0.834, 0.830, 0.715, 0.226, and 0.439, respectively. The average central macular thickness (CMT) was significantly correlated with the CVs of NFL (coefficient = 0.317; P < 0.001), GCL (coefficient = 0.328; P < 0.001), and IPL (coefficient = 0.186; P = 0.042) in Group 1.</p><p><strong>Conclusions: </strong>The reproducibility of the inner retinal layer thickness measurements in ERM patients with EIFLs was low compared to those without EIFLs. The reproducibility of the outer retinal layer thickness measurements, including OPL and ONL, was poor regardless of the presence of EIFLs in ERM patients. Additionally, the thicker the CMT in patients with EIFLs, the lower the reproducibility of the inner retinal layer thickness measurements.</p>","PeriodicalId":12194,"journal":{"name":"Eye and Vision","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2023-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9811706/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-022-00321-2","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To identify the reliability of each retinal layer thickness measurement in epiretinal membrane (ERM) patients with ectopic inner foveal layers (EIFLs).

Methods: Subjects were divided into two groups: ERM patients with EIFLs (Group 1) and without EIFLs (Group 2). The retinal layer thickness was measured twice, and intraclass correlation coefficient (ICC) and coefficient of variation (CV) values were calculated.

Results: In Group 1, the CVs of the nerve fiber layer (NFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), and outer nuclear layer (ONL) were 22.39%, 13.12%, 13.37%, 13.21%, 15.09%, and 11.94%, while the ICCs were 0.431, 0.550, 0.440, 0.286, 0.279, and 0.503, respectively. In Group 2, the CVs were 18.20%, 10.59%, 10.65%, 13.27%, 14.75%, and 10.37%, while the ICCs were 0.788, 0.834, 0.830, 0.715, 0.226, and 0.439, respectively. The average central macular thickness (CMT) was significantly correlated with the CVs of NFL (coefficient = 0.317; P < 0.001), GCL (coefficient = 0.328; P < 0.001), and IPL (coefficient = 0.186; P = 0.042) in Group 1.

Conclusions: The reproducibility of the inner retinal layer thickness measurements in ERM patients with EIFLs was low compared to those without EIFLs. The reproducibility of the outer retinal layer thickness measurements, including OPL and ONL, was poor regardless of the presence of EIFLs in ERM patients. Additionally, the thicker the CMT in patients with EIFLs, the lower the reproducibility of the inner retinal layer thickness measurements.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
视网膜前膜内中央凹层异位患者各视网膜层厚度测量的可重复性。
背景:确定视网膜前膜(ERM)内中央凹层异位(eifl)患者各视网膜层厚度测量的可靠性。方法:将受试者分为有eifl的ERM患者(1组)和无eifl的ERM患者(2组),测量视网膜层厚度2次,计算类内相关系数(ICC)和变异系数(CV)值。结果:1组神经纤维层(NFL)、神经节细胞层(GCL)、内丛状层(IPL)、内核层(INL)、外丛状层(OPL)、外核层(ONL)的CVs分别为22.39%、13.12%、13.37%、13.21%、15.09%、11.94%,ICCs分别为0.431、0.550、0.440、0.286、0.279、0.503。第2组的cv分别为18.20%、10.59%、10.65%、13.27%、14.75%和10.37%,ICCs分别为0.788、0.834、0.830、0.715、0.226和0.439。平均中央黄斑厚度(CMT)与NFL的cv呈显著相关(系数= 0.317;结论:与没有eifl的ERM患者相比,eifl患者视网膜内层厚度测量的可重复性较低。无论ERM患者是否存在eifl,包括OPL和ONL在内的视网膜外层厚度测量的再现性都很差。此外,eifs患者的CMT越厚,视网膜内层厚度测量的可重复性越低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Eye and Vision
Eye and Vision OPHTHALMOLOGY-
CiteScore
8.60
自引率
2.40%
发文量
89
审稿时长
15 weeks
期刊介绍: Eye and Vision is an open access, peer-reviewed journal for ophthalmologists and visual science specialists. It welcomes research articles, reviews, methodologies, commentaries, case reports, perspectives and short reports encompassing all aspects of eye and vision. Topics of interest include but are not limited to: current developments of theoretical, experimental and clinical investigations in ophthalmology, optometry and vision science which focus on novel and high-impact findings on central issues pertaining to biology, pathophysiology and etiology of eye diseases as well as advances in diagnostic techniques, surgical treatment, instrument updates, the latest drug findings, results of clinical trials and research findings. It aims to provide ophthalmologists and visual science specialists with the latest developments in theoretical, experimental and clinical investigations in eye and vision.
期刊最新文献
Advances and prospects of multi-modal ophthalmic artificial intelligence based on deep learning: a review. Ten-year trends of delayed sequential bilateral cataract surgery (DSBCS) in Sweden: a register-based study. An L-type calcium channel blocker nimodipine exerts anti-fibrotic effects by attenuating TGF-β1 induced calcium response in an in vitro model of thyroid eye disease. Efficacy of orthokeratology lens with the modified small treatment zone on myopia progression and visual quality: a randomized clinical trial. Nominal and achieved stromal ablation depth after myopic transepithelial photorefractive keratectomy: implications for residual stromal thickness calculation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1