The Significance of Serum IgG4/IgG and IgG4/IgG1 Ratio in the Diagnosis Value of IgG4-Related Diseases.

IF 2 4区 医学 Q3 MEDICINE, RESEARCH & EXPERIMENTAL Discovery medicine Pub Date : 2023-08-01 DOI:10.24976/Discov.Med.202335177.48
Wei Wang, Yuanyuan Li, He Feng
{"title":"The Significance of Serum IgG4/IgG and IgG4/IgG1 Ratio in the Diagnosis Value of IgG4-Related Diseases.","authors":"Wei Wang,&nbsp;Yuanyuan Li,&nbsp;He Feng","doi":"10.24976/Discov.Med.202335177.48","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Elevated serum immunoglobulin G4 (IgG4) is one of the important features of patients with IgG4-related diseases (IgG4-RD). But diagnosing these diseases using IgG4 alone is tricky because the tests can sometimes give inaccurate results. Our research is focused on studying the ratio of IgG4 to two other substances, immunoglobulin G (IgG) and immunoglobulin G1 (IgG1), in the blood. We hope this approach will lead to more accurate diagnoses of IgG4-RD.</p><p><strong>Methods: </strong>We conducted a study on 68 patients diagnosed with IgG4-related diseases (IgG4-RD) and 160 individuals suffering from other autoimmune diseases (AID) at our hospital between June 2018 and June 2022. Eighty healthy people who underwent physical examination in our hospital at the same time were randomly selected as controls, and medical records were collected for all subjects. The serum IgG and IgG subclasses were detected, and the IgG4/IgG and IgG4/IgG1 ratios were calculated.</p><p><strong>Results: </strong>We found that patients with IgG4-RD have significantly higher average levels of serum IgG4 and more elevated IgG4/IgG and IgG4/IgG1 ratios compared to individuals with other AID patients and those in good health (<i>p</i> < 0.001). The receiver operating characteristic (ROC) curve analysis showed that the diagnostic effectiveness area under the curve (AUC) of the serum IgG4/IgG ratio for IgG4-RD was 0.906 (95% confidence interval [CI], 0.865-0.947) and 0.921 (95% CI, 0.876-0.965) when comparing with other AID patients and healthy individuals, respectively. The optimal cut-off value for the IgG4/IgG ratio was 0.147 (with 72.1% sensitivity and 94.4% specificity) compared with AID patients and 0.129 (with 77.9% sensitivity and 96.2% specificity) compared with healthy individuals. Similarly, the AUC of the serum IgG4/IgG1 ratio for diagnosing IgG4-RD was 0.919 (95% CI, 0.882-0.956) and 0.916 (95% CI, 0.870-0.962) when compared with patients with other AID and healthy individuals, respectively. When we divided our study participants into a high IgG4/IgG ratio group (>0.129) and a normal IgG4/IgG ratio group (≤0.129) using a cut-off point of 0.129, we found through logistic regression analysis that those with a high IgG4/IgG ratio were more likely to be associated with IgG4-RD (odds ratio [OR], 31.25; 95% CI, 15.31-63.79; <i>p</i> < 0.001). Likewise, a high IgG4/IgG1 ratio was also significantly linked to an increased risk of IgG4-RD (OR, 36.39; 95% CI, 17.57-75.38; <i>p</i> < 0.001).</p><p><strong>Conclusions: </strong>The serum's IgG4/IgG and IgG4/IgG1 ratios are independently linked to IgG4-RD and are valuable in its diagnosis.</p>","PeriodicalId":11379,"journal":{"name":"Discovery medicine","volume":"35 177","pages":"476-482"},"PeriodicalIF":2.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Discovery medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.24976/Discov.Med.202335177.48","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Elevated serum immunoglobulin G4 (IgG4) is one of the important features of patients with IgG4-related diseases (IgG4-RD). But diagnosing these diseases using IgG4 alone is tricky because the tests can sometimes give inaccurate results. Our research is focused on studying the ratio of IgG4 to two other substances, immunoglobulin G (IgG) and immunoglobulin G1 (IgG1), in the blood. We hope this approach will lead to more accurate diagnoses of IgG4-RD.

Methods: We conducted a study on 68 patients diagnosed with IgG4-related diseases (IgG4-RD) and 160 individuals suffering from other autoimmune diseases (AID) at our hospital between June 2018 and June 2022. Eighty healthy people who underwent physical examination in our hospital at the same time were randomly selected as controls, and medical records were collected for all subjects. The serum IgG and IgG subclasses were detected, and the IgG4/IgG and IgG4/IgG1 ratios were calculated.

Results: We found that patients with IgG4-RD have significantly higher average levels of serum IgG4 and more elevated IgG4/IgG and IgG4/IgG1 ratios compared to individuals with other AID patients and those in good health (p < 0.001). The receiver operating characteristic (ROC) curve analysis showed that the diagnostic effectiveness area under the curve (AUC) of the serum IgG4/IgG ratio for IgG4-RD was 0.906 (95% confidence interval [CI], 0.865-0.947) and 0.921 (95% CI, 0.876-0.965) when comparing with other AID patients and healthy individuals, respectively. The optimal cut-off value for the IgG4/IgG ratio was 0.147 (with 72.1% sensitivity and 94.4% specificity) compared with AID patients and 0.129 (with 77.9% sensitivity and 96.2% specificity) compared with healthy individuals. Similarly, the AUC of the serum IgG4/IgG1 ratio for diagnosing IgG4-RD was 0.919 (95% CI, 0.882-0.956) and 0.916 (95% CI, 0.870-0.962) when compared with patients with other AID and healthy individuals, respectively. When we divided our study participants into a high IgG4/IgG ratio group (>0.129) and a normal IgG4/IgG ratio group (≤0.129) using a cut-off point of 0.129, we found through logistic regression analysis that those with a high IgG4/IgG ratio were more likely to be associated with IgG4-RD (odds ratio [OR], 31.25; 95% CI, 15.31-63.79; p < 0.001). Likewise, a high IgG4/IgG1 ratio was also significantly linked to an increased risk of IgG4-RD (OR, 36.39; 95% CI, 17.57-75.38; p < 0.001).

Conclusions: The serum's IgG4/IgG and IgG4/IgG1 ratios are independently linked to IgG4-RD and are valuable in its diagnosis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血清IgG4/IgG及IgG4/IgG1比值在IgG4相关疾病诊断中的意义
目的:血清免疫球蛋白G4 (IgG4)升高是IgG4相关疾病(IgG4- rd)患者的重要特征之一。但是单独使用IgG4来诊断这些疾病是很棘手的,因为测试有时会给出不准确的结果。我们的研究重点是研究IgG4与血液中另外两种物质免疫球蛋白G (IgG)和免疫球蛋白G1 (IgG1)的比例。我们希望这种方法能够更准确地诊断IgG4-RD。方法:我们对2018年6月至2022年6月在我院诊断为igg4相关疾病(IgG4-RD)的68例患者和160例其他自身免疫性疾病(AID)患者进行了研究。随机选取同期在我院体检的健康人群80人作为对照,收集所有受试者的病历。检测血清IgG和IgG亚类,计算IgG4/IgG和IgG4/IgG1比值。结果:我们发现,与其他AID患者和健康状况良好的患者相比,IgG4- rd患者的血清IgG4平均水平显著升高,IgG4/IgG和IgG4/IgG1比值升高(p < 0.001)。受试者工作特征(ROC)曲线分析显示,血清IgG4/IgG比值对IgG4- rd的诊断曲线下有效面积(AUC)分别为0.906(95%可信区间[CI] 0.865 ~ 0.947)和0.921 (95% CI 0.876 ~ 0.965)。与艾滋病患者相比,IgG4/IgG比值的最佳临界值为0.147(敏感性为72.1%,特异性为94.4%);与健康个体相比,最佳临界值为0.129(敏感性为77.9%,特异性为96.2%)。同样,血清IgG4/IgG1比值诊断IgG4- rd的AUC分别为0.919 (95% CI 0.882-0.956)和0.916 (95% CI 0.870-0.962)。当我们使用截断点0.129将研究参与者分为高IgG4/IgG比组(>0.129)和正常IgG4/IgG比组(≤0.129)时,我们发现通过logistic回归分析,IgG4/IgG比高的参与者更有可能与IgG4- rd相关(比值比[OR], 31.25;95% ci, 15.31-63.79;P < 0.001)。同样,高IgG4/IgG1比值也与IgG4- rd风险增加显著相关(OR, 36.39;95% ci, 17.57-75.38;P < 0.001)。结论:血清IgG4/IgG和IgG4/IgG1比值与IgG4- rd独立相关,对其诊断有价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Discovery medicine
Discovery medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
5.40
自引率
0.00%
发文量
80
审稿时长
6-12 weeks
期刊介绍: Discovery Medicine publishes novel, provocative ideas and research findings that challenge conventional notions about disease mechanisms, diagnosis, treatment, or any of the life sciences subjects. It publishes cutting-edge, reliable, and authoritative information in all branches of life sciences but primarily in the following areas: Novel therapies and diagnostics (approved or experimental); innovative ideas, research technologies, and translational research that will give rise to the next generation of new drugs and therapies; breakthrough understanding of mechanism of disease, biology, and physiology; and commercialization of biomedical discoveries pertaining to the development of new drugs, therapies, medical devices, and research technology.
期刊最新文献
The Action Mechanisms, Anti-Cancer and Antibiotic-Modulation Potential of Vaccinium myrtillus L. Extract. Development and Comparative Analysis of an Early Prediction Model for Acute Kidney Injury within 72-Hours Post-ICU Admission Using Evidence from the MIMIC-III Database. H2S Alleviates Propofol-Induced Impaired Learning and Memory by Promoting Nuclear Translocation of Nrf2 and Inhibiting Apoptosis and Pyroptosis in Hippocampal Neurons. Animal Feasibility Study of a Novel Spinal Cord Stimulation Multicolumn Lead (Heron Lead). The Clinical Significance of iNOS/NO Signaling Pathway in Traumatic Shock and the Mechanism under the Promotion on the Development of Traumatic Shock via Endoplasmic Reticulum Stress.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1