High precision but systematic offset in a standing bioelectrical impedance analysis (BIA) compared with dual-energy X-ray absorptiometry (DXA).

IF 3.3 Q2 NUTRITION & DIETETICS BMJ Nutrition, Prevention and Health Pub Date : 2022-12-01 DOI:10.1136/bmjnph-2022-000512
Adam W Potter, Lyndsey J Nindl, Lara D Soto, Angie Pazmino, David P Looney, William J Tharion, Jasmine A Robinson-Espinosa, Karl E Friedl
{"title":"High precision but systematic offset in a standing bioelectrical impedance analysis (BIA) compared with dual-energy X-ray absorptiometry (DXA).","authors":"Adam W Potter,&nbsp;Lyndsey J Nindl,&nbsp;Lara D Soto,&nbsp;Angie Pazmino,&nbsp;David P Looney,&nbsp;William J Tharion,&nbsp;Jasmine A Robinson-Espinosa,&nbsp;Karl E Friedl","doi":"10.1136/bmjnph-2022-000512","DOIUrl":null,"url":null,"abstract":"<p><p>Bioelectrical impedance analysis (BIA) provides a practical method of body composition estimation for field research and weight management programmes, with devices and algorithms that have improved in recent years. We compared suitability of a commercial BIA system that uses multi-frequency-based proprietary algorithms (InBody 770, Cerritos, California, USA) and a laboratory-based validated single-frequency system (Quantum IV, RJL Systems, Clinton Township, Michigan, USA) with dual-energy X-ray absorptiometry (DXA) (iDXA, GE Lunar, Madison, Wisconsin, USA). Volunteers included fit non-obese active duty US Marines (480 men; 315 women), assessed by DXA and the two BIA systems. Both RJL and InBody BIA devices predicted DXA-based fat-free mass (FFM) (mean absolute error (MAE) 2.8 and 3.1 kg, respectively) and per cent body fat (%BF) (MAE 3.4% and 3.9%, respectively), with higher correlations from the InBody device (r<sup>2</sup>=0.96 (%BF) and 0.84 (FFM)) versus the RJL (r<sup>2</sup>=0.92 (%BF) and 0.72 (FFM)). InBody overpredicted FFM (bias +2.7, MAE 3.1 kg) and underpredicted %BF (bias -3.4 and MAE 3.9%) versus the RJL. A 3% correction factor applied to the InBody device results provided values very close to the DXA measurements. These findings support the application of modern BIA systems to body composition goals of maximum %BF and minimum lean body mass for both men and women.</p>","PeriodicalId":36307,"journal":{"name":"BMJ Nutrition, Prevention and Health","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/56/46/bmjnph-2022-000512.PMC9813632.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Nutrition, Prevention and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjnph-2022-000512","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 2

Abstract

Bioelectrical impedance analysis (BIA) provides a practical method of body composition estimation for field research and weight management programmes, with devices and algorithms that have improved in recent years. We compared suitability of a commercial BIA system that uses multi-frequency-based proprietary algorithms (InBody 770, Cerritos, California, USA) and a laboratory-based validated single-frequency system (Quantum IV, RJL Systems, Clinton Township, Michigan, USA) with dual-energy X-ray absorptiometry (DXA) (iDXA, GE Lunar, Madison, Wisconsin, USA). Volunteers included fit non-obese active duty US Marines (480 men; 315 women), assessed by DXA and the two BIA systems. Both RJL and InBody BIA devices predicted DXA-based fat-free mass (FFM) (mean absolute error (MAE) 2.8 and 3.1 kg, respectively) and per cent body fat (%BF) (MAE 3.4% and 3.9%, respectively), with higher correlations from the InBody device (r2=0.96 (%BF) and 0.84 (FFM)) versus the RJL (r2=0.92 (%BF) and 0.72 (FFM)). InBody overpredicted FFM (bias +2.7, MAE 3.1 kg) and underpredicted %BF (bias -3.4 and MAE 3.9%) versus the RJL. A 3% correction factor applied to the InBody device results provided values very close to the DXA measurements. These findings support the application of modern BIA systems to body composition goals of maximum %BF and minimum lean body mass for both men and women.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
与双能x射线吸收仪(DXA)相比,常备生物电阻抗分析(BIA)精度高,但系统偏移。
生物电阻抗分析(BIA)为现场研究和体重管理计划提供了一种实用的身体成分估计方法,近年来设备和算法得到了改进。我们比较了使用基于多频率的专有算法的商用BIA系统(InBody 770, Cerritos, California, USA)和基于实验室的验证单频系统(Quantum IV, RJL Systems, Clinton Township, Michigan, USA)与双能x射线吸收仪(DXA) (iDXA, GE Lunar, Madison, Wisconsin, USA)的适用性。志愿者包括健康、不肥胖的现役美国海军陆战队员(480人;315名女性),通过DXA和两个BIA系统进行评估。RJL和InBody BIA设备都预测了基于dx的无脂质量(FFM)(平均绝对误差(MAE)分别为2.8和3.1 kg)和体脂百分比(%BF) (MAE分别为3.4%和3.9%),InBody设备(r2=0.96 (%BF)和0.84 (FFM))与RJL (r2=0.92 (%BF)和0.72 (FFM))的相关性更高。与RJL相比,InBody高估了FFM(偏差+2.7,MAE 3.1 kg),低估了%BF(偏差-3.4,MAE 3.9%)。将3%的校正因子应用于InBody设备结果,提供的值非常接近DXA测量值。这些发现支持现代BIA系统应用于男性和女性的最大BF %和最小瘦体重的身体组成目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMJ Nutrition, Prevention and Health
BMJ Nutrition, Prevention and Health Nursing-Nutrition and Dietetics
CiteScore
5.80
自引率
0.00%
发文量
34
期刊最新文献
Landscape analysis of environmental, social and governance (ESG) investing metrics for consumer nutrition and health in the food and beverage sector. Maternal prenatal, with or without postpartum, vitamin D3 supplementation does not improve maternal iron status at delivery or infant iron status at 6 months of age: secondary analysis of a randomised controlled trial Effects of behavioural change communication (BCC) on menstrual hygiene practices among urban school adolescent girls: a pilot study Physiotherapy-led telehealth and exercise intervention to improve mobility in older people receiving aged care services (TOP UP): protocol for a randomised controlled type 1 hybrid effectiveness-implementation trial Effects of a 5-week intake of erythritol and xylitol on vascular function, abdominal fat and glucose tolerance in humans with obesity: a pilot trial
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1