{"title":"Usefulness and Educational Benefit of a Virtual Scale Endoscope in Measuring Colorectal Polyp Size.","authors":"Yudai Takehara, Ken Yamashita, Shin Morimoto, Fumiaki Tanino, Noriko Yamamoto, Yuki Kamigaichi, Hidenori Tanaka, Hidehiko Takigawa, Ryo Yuge, Yuji Urabe, Shiro Oka","doi":"10.1159/000533326","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The virtual scale endoscope (VSE) is a newly introduced endoscope that helps endoscopists in measuring colorectal polyp size (CPS) during colonoscopy by displaying a virtual scale. This study aimed to determine the usefulness of the VSE for CPS measurement and the educational benefit of using VSE images to improve CPS estimation accuracy.</p><p><strong>Methods: </strong>This study included 42 colorectal polyps in 26 patients treated at Hiroshima University Hospital. In study 1, CPS measured using a VSE before endoscopic mucosal resection was compared with CPS measured on resected specimens, and the agreement between the two measurement methods was evaluated via Bland-Altman analysis. In study 2, 14 endoscopists (5 beginners, 5 intermediates, and 4 experts) took a pre-test to determine the size of 42 polyps. After the pre-test, a lecture on CPS measurement using VSE images was given. One month later, the endoscopists took a post-test to compare CPS accuracy before and after the lecture.</p><p><strong>Results: </strong>In study 1, Bland-Altman analysis revealed no fixed or proportional errors. The mean bias ±95% limits of agreement (±1.96 standard deviations) of the measurement error was -0.05 ± 0.21 mm, indicating that the agreement between two measurement methods was sufficient. In study 2, the accuracy of CPS measurement was significantly higher among beginners (59.5% vs. 26.7%, p < 0.01) and intermediates (65.2% vs. 44.3%, p < 0.05) in the post-test than in the pre-test.</p><p><strong>Conclusion: </strong>The VSE accurately measures CPS before resection, and its images are useful teaching tools for beginner and intermediate endoscopists.</p>","PeriodicalId":11315,"journal":{"name":"Digestion","volume":" ","pages":"73-80"},"PeriodicalIF":3.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000533326","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: The virtual scale endoscope (VSE) is a newly introduced endoscope that helps endoscopists in measuring colorectal polyp size (CPS) during colonoscopy by displaying a virtual scale. This study aimed to determine the usefulness of the VSE for CPS measurement and the educational benefit of using VSE images to improve CPS estimation accuracy.
Methods: This study included 42 colorectal polyps in 26 patients treated at Hiroshima University Hospital. In study 1, CPS measured using a VSE before endoscopic mucosal resection was compared with CPS measured on resected specimens, and the agreement between the two measurement methods was evaluated via Bland-Altman analysis. In study 2, 14 endoscopists (5 beginners, 5 intermediates, and 4 experts) took a pre-test to determine the size of 42 polyps. After the pre-test, a lecture on CPS measurement using VSE images was given. One month later, the endoscopists took a post-test to compare CPS accuracy before and after the lecture.
Results: In study 1, Bland-Altman analysis revealed no fixed or proportional errors. The mean bias ±95% limits of agreement (±1.96 standard deviations) of the measurement error was -0.05 ± 0.21 mm, indicating that the agreement between two measurement methods was sufficient. In study 2, the accuracy of CPS measurement was significantly higher among beginners (59.5% vs. 26.7%, p < 0.01) and intermediates (65.2% vs. 44.3%, p < 0.05) in the post-test than in the pre-test.
Conclusion: The VSE accurately measures CPS before resection, and its images are useful teaching tools for beginner and intermediate endoscopists.
期刊介绍:
''Digestion'' concentrates on clinical research reports: in addition to editorials and reviews, the journal features sections on Stomach/Esophagus, Bowel, Neuro-Gastroenterology, Liver/Bile, Pancreas, Metabolism/Nutrition and Gastrointestinal Oncology. Papers cover physiology in humans, metabolic studies and clinical work on the etiology, diagnosis, and therapy of human diseases. It is thus especially cut out for gastroenterologists employed in hospitals and outpatient units. Moreover, the journal''s coverage of studies on the metabolism and effects of therapeutic drugs carries considerable value for clinicians and investigators beyond the immediate field of gastroenterology.