{"title":"Accuracy of the SRK/T Formula in Pediatric Cataract Surgery.","authors":"Irawati Irfani, Tri Wahyu, Primawita Oktarima, Sesy Caesarya, Maya Sari, Feti Karfiati","doi":"10.2147/OPTO.S390994","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Determining IOL power is an important step in achieving the desired postoperative refractive target, but this determination remains challenging, as currently the used formulas were developed using IOL power calculations derived from adults.</p><p><strong>Patients and methods: </strong>This is a retrospective analytical study with the period of June 2018 to May 2019. All of the data were taken from medical records in referral tertiary eye hospital in Indonesia. All type of cataracts underwent uncomplicated surgeries and in-the-bag IOL implantation were included in this study, while aphakia, secondary IOL implantation, primary sulcus implantation, and history of ocular disorders were excluded. The data were analyzed using Wilcoxon sign-rank, paired t, and Kruskal-Wallis tests.</p><p><strong>Results: </strong>Sixty-seven patients (106 eyes) were found to meet the inclusion criteria, average age was 7.35 ± 4.61 years (1.00 to 17.00 years). Average targeted refraction was 1.69 ± 2.06 D (-0.38-+6.99 D), and spherical equivalent (actual postoperative refraction) was -0.90 ± 1.45 D (-4.38 to +2.75 D). There was statistically significant difference between preoperative targeted refraction and actual postoperative refraction (p < 0.001). Mean absolute prediction error (APE) in general was 1.34 ± 1.18 D, 1.22 ± 0.88 D (in short eyes), 1.52 ± 1.37 D (in moderate eyes), and 0.69 ± 0.52 D (in long eyes) (p = 0.202). Mean APE in age group <7 years old was 1.27 ± 1.18 D and ≥7 years-old was 1.42 ± 1.19 D (p = 0.429).</p><p><strong>Conclusion: </strong>SRK/T formula is fairly accurate in calculating IOL power in pediatric cataract surgery. Mean APE in this study was within the range of accurate mean APE in pediatric patients despite differentiated axial length and age.</p>","PeriodicalId":43701,"journal":{"name":"Clinical Optometry","volume":"15 ","pages":"1-8"},"PeriodicalIF":1.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1f/e3/opto-15-1.PMC9826636.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Optometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTO.S390994","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Determining IOL power is an important step in achieving the desired postoperative refractive target, but this determination remains challenging, as currently the used formulas were developed using IOL power calculations derived from adults.
Patients and methods: This is a retrospective analytical study with the period of June 2018 to May 2019. All of the data were taken from medical records in referral tertiary eye hospital in Indonesia. All type of cataracts underwent uncomplicated surgeries and in-the-bag IOL implantation were included in this study, while aphakia, secondary IOL implantation, primary sulcus implantation, and history of ocular disorders were excluded. The data were analyzed using Wilcoxon sign-rank, paired t, and Kruskal-Wallis tests.
Results: Sixty-seven patients (106 eyes) were found to meet the inclusion criteria, average age was 7.35 ± 4.61 years (1.00 to 17.00 years). Average targeted refraction was 1.69 ± 2.06 D (-0.38-+6.99 D), and spherical equivalent (actual postoperative refraction) was -0.90 ± 1.45 D (-4.38 to +2.75 D). There was statistically significant difference between preoperative targeted refraction and actual postoperative refraction (p < 0.001). Mean absolute prediction error (APE) in general was 1.34 ± 1.18 D, 1.22 ± 0.88 D (in short eyes), 1.52 ± 1.37 D (in moderate eyes), and 0.69 ± 0.52 D (in long eyes) (p = 0.202). Mean APE in age group <7 years old was 1.27 ± 1.18 D and ≥7 years-old was 1.42 ± 1.19 D (p = 0.429).
Conclusion: SRK/T formula is fairly accurate in calculating IOL power in pediatric cataract surgery. Mean APE in this study was within the range of accurate mean APE in pediatric patients despite differentiated axial length and age.
期刊介绍:
Clinical Optometry is an international, peer-reviewed, open access journal focusing on clinical optometry. All aspects of patient care are addressed within the journal as well as the practice of optometry including economic and business analyses. Basic and clinical research papers are published that cover all aspects of optics, refraction and its application to the theory and practice of optometry. Specific topics covered in the journal include: Theoretical and applied optics, Delivery of patient care in optometry practice, Refraction and correction of errors, Screening and preventative aspects of eye disease, Extended clinical roles for optometrists including shared care and provision of medications, Teaching and training optometrists, International aspects of optometry, Business practice, Patient adherence, quality of life, satisfaction, Health economic evaluations.