Reliability of inter-recti distance measurement on ultrasound images captured by novice examiners.

IF 1.5 4区 医学 Q2 REHABILITATION Physiotherapy Theory and Practice Pub Date : 2024-11-01 Epub Date: 2023-09-11 DOI:10.1080/09593985.2023.2255897
Daria Chmielewska, Maciej Cebula, Rafał Gnat, Magdalena Rudek-Zeprzałka, Katarzyna Gruszczyńska, Jan Baron, Agnieszka Opala-Berdzik
{"title":"Reliability of inter-recti distance measurement on ultrasound images captured by novice examiners.","authors":"Daria Chmielewska, Maciej Cebula, Rafał Gnat, Magdalena Rudek-Zeprzałka, Katarzyna Gruszczyńska, Jan Baron, Agnieszka Opala-Berdzik","doi":"10.1080/09593985.2023.2255897","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>With the increased interest in inter-recti distance measurement using ultrasound imaging in physiotherapy, there is a question of measurement reliability, and the importance of the examiner's experience.</p><p><strong>Purpose: </strong>The study aimed to investigate the reliability of inter-recti distance measurement in a DICOM viewer software by an experienced radiologist. For the measurement, the radiologist used linea alba images captured by two physiotherapists who were novice examiners.</p><p><strong>Methods: </strong>Ultrasound images were acquired by two novice examiners on repeated occasions 7 days apart (sessions A and B) in 28 nulliparous women at supraumbilical, umbilical, and infraumbilical locations along linea alba.</p><p><strong>Results: </strong>Excellent intra-examiner reliability of inter-recti distance measurements was shown at the supraumbilical and umbilical levels (ICC<sub>2,k</sub> = 0.941-0.983) with minimal detectable change (MDC<sub>95</sub>) ranging from 1.31 mm to 2.29 mm. Infraumbilical measurements had good to excellent reliability (ICC<sub>2,k</sub> = 0.894-0.972) with MDC<sub>95</sub> ranging from 0.33 mm to 0.72 mm. Session A inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at each location (ICC<sub>2,k</sub> = 0.913-0.954) with MDC<sub>95</sub> ranging from 0.47 mm to 2.96 mm. Session B inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at the supraumbilical and umbilical (ICC<sub>2,k</sub> = 0.94-0.98), MDC<sub>95</sub> ranging from 1.38 mm to 2.58 mm and good (ICC<sub>2,k</sub> ≥ 0.81) with MDC<sub>95</sub> ranging from 0.72 mm to 0.80 mm at the infraumbilical locations.</p><p><strong>Conclusion: </strong>Novice examiners were able to capture good-quality ultrasound images of the linea alba that allowed for good to excellent intra- and inter-examiner reliability.</p>","PeriodicalId":48699,"journal":{"name":"Physiotherapy Theory and Practice","volume":" ","pages":"2652-2660"},"PeriodicalIF":1.5000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiotherapy Theory and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09593985.2023.2255897","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

Abstract

Background: With the increased interest in inter-recti distance measurement using ultrasound imaging in physiotherapy, there is a question of measurement reliability, and the importance of the examiner's experience.

Purpose: The study aimed to investigate the reliability of inter-recti distance measurement in a DICOM viewer software by an experienced radiologist. For the measurement, the radiologist used linea alba images captured by two physiotherapists who were novice examiners.

Methods: Ultrasound images were acquired by two novice examiners on repeated occasions 7 days apart (sessions A and B) in 28 nulliparous women at supraumbilical, umbilical, and infraumbilical locations along linea alba.

Results: Excellent intra-examiner reliability of inter-recti distance measurements was shown at the supraumbilical and umbilical levels (ICC2,k = 0.941-0.983) with minimal detectable change (MDC95) ranging from 1.31 mm to 2.29 mm. Infraumbilical measurements had good to excellent reliability (ICC2,k = 0.894-0.972) with MDC95 ranging from 0.33 mm to 0.72 mm. Session A inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at each location (ICC2,k = 0.913-0.954) with MDC95 ranging from 0.47 mm to 2.96 mm. Session B inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at the supraumbilical and umbilical (ICC2,k = 0.94-0.98), MDC95 ranging from 1.38 mm to 2.58 mm and good (ICC2,k ≥ 0.81) with MDC95 ranging from 0.72 mm to 0.80 mm at the infraumbilical locations.

Conclusion: Novice examiners were able to capture good-quality ultrasound images of the linea alba that allowed for good to excellent intra- and inter-examiner reliability.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对新手检查员拍摄的超声波图像进行直间距离测量的可靠性。
背景:目的:本研究旨在调查一位经验丰富的放射科医生在 DICOM 查看器软件中进行直间距离测量的可靠性。在测量过程中,放射科医生使用了由两名新手物理治疗师采集的白线图像:方法:由两名新手检查员在相隔 7 天的重复场合(A 和 B 次)采集 28 名无产科妇女的脐上、脐部和脐下沿白线位置的超声波图像:脐上和脐下的直间距测量结果显示出极佳的检查者内部可靠性(ICC2,k = 0.941-0.983),最小可检测变化(MDC95)范围为 1.31 毫米至 2.29 毫米。脐下测量的可靠性从良好到极佳(ICC2,k = 0.894-0.972),MDC95 在 0.33 毫米到 0.72 毫米之间。A 次检查中,每个位置的两张、三张、四张和五张图像的平均测量值的检查者间可靠性极佳(ICC2,k = 0.913-0.954),MDC95 范围为 0.47 毫米至 2.96 毫米。在脐上和脐下拍摄的两张、三张、四张和五张图像的平均测量值(ICC2,k = 0.94-0.98),MDC95 的范围为 1.38 毫米至 2.58 毫米;在脐下位置拍摄的两张、三张、四张和五张图像的平均测量值(ICC2,k ≥ 0.81),MDC95 的范围为 0.72 毫米至 0.80 毫米:结论:新手检查者能够捕捉到高质量的白线超声图像,检查者内部和检查者之间的可靠性良好甚至极佳。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.40
自引率
10.00%
发文量
300
期刊介绍: The aim of Physiotherapy Theory and Practice is to provide an international, peer-reviewed forum for the publication, dissemination, and discussion of recent developments and current research in physiotherapy/physical therapy. The journal accepts original quantitative and qualitative research reports, theoretical papers, systematic literature reviews, clinical case reports, and technical clinical notes. Physiotherapy Theory and Practice; promotes post-basic education through reports, reviews, and updates on all aspects of physiotherapy and specialties relating to clinical physiotherapy.
期刊最新文献
Letter to the editor on "Effectiveness of motor imagery training in women with chronic neck pain: A single-blind, randomized controlled trial". Musculoskeletal injury incidence, associated factors, and players' beliefs in beach tennis: a cross-sectional study. Examining the frequency, severity and associated factors of burnout in Nebraska physical therapists. Interference of functional dual-tasks on static posturography in people with Parkinson's disease. Patient perspectives of a physiotherapy-led musculoskeletal community event: A mixed methods survey.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1