Conversion hip arthroplasty for failed internal fixation of ipsilateral femoral neck and shaft fractures: a case report.

IF 2.6 Q1 SURGERY Patient Safety in Surgery Pub Date : 2023-01-19 DOI:10.1186/s13037-023-00352-1
Marlon M Mencia, Pablo Pedro Hernandez Cruz
{"title":"Conversion hip arthroplasty for failed internal fixation of ipsilateral femoral neck and shaft fractures: a case report.","authors":"Marlon M Mencia,&nbsp;Pablo Pedro Hernandez Cruz","doi":"10.1186/s13037-023-00352-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ipsilateral femoral neck and hip fractures are uncommon high energy injuries. In the literature no single method of treatment has emerged as superior to the others. A recent publication has documented the successful application of the rendezvous technique using dual-implants for treating these injuries. However in some cases, this technique may fail and revision surgery is required.</p><p><strong>Case presentation: </strong>A 67-year old man sustained ipsilateral fractures of his femur and femoral neck in a road traffic accident. His injuries were treated by a dual construct consisting of a retrograde femoral nail and dynamic hip screw. Three months after surgery the hip screw cut out of the femoral head necessitating revision to a total hip arthroplasty. Surgery was carried out using a single stage two part procedure on a standard operating table without having to reposition or redrape the patient. There were no postoperative complications and at 1 year from surgery the patient is satisfied with the result and has returned to work.</p><p><strong>Conclusion: </strong>Conversion hip arthroplasty in the presence of dual implants is a technically challenging and unpredictable procedure, with an increased risk of complications. Our surgical approach provides a framework for orthopedic surgeons to safely perform this complex procedure.</p>","PeriodicalId":46782,"journal":{"name":"Patient Safety in Surgery","volume":"17 1","pages":"1"},"PeriodicalIF":2.6000,"publicationDate":"2023-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9850509/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patient Safety in Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13037-023-00352-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Ipsilateral femoral neck and hip fractures are uncommon high energy injuries. In the literature no single method of treatment has emerged as superior to the others. A recent publication has documented the successful application of the rendezvous technique using dual-implants for treating these injuries. However in some cases, this technique may fail and revision surgery is required.

Case presentation: A 67-year old man sustained ipsilateral fractures of his femur and femoral neck in a road traffic accident. His injuries were treated by a dual construct consisting of a retrograde femoral nail and dynamic hip screw. Three months after surgery the hip screw cut out of the femoral head necessitating revision to a total hip arthroplasty. Surgery was carried out using a single stage two part procedure on a standard operating table without having to reposition or redrape the patient. There were no postoperative complications and at 1 year from surgery the patient is satisfied with the result and has returned to work.

Conclusion: Conversion hip arthroplasty in the presence of dual implants is a technically challenging and unpredictable procedure, with an increased risk of complications. Our surgical approach provides a framework for orthopedic surgeons to safely perform this complex procedure.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
置换髋关节置换术治疗同侧股骨颈骨折及股骨骨干骨折内固定失败1例。
背景:同侧股骨颈和髋部骨折是一种少见的高能量损伤。在文献中,没有一种治疗方法优于其他方法。最近的一份出版物记录了使用双植入物治疗这些损伤的交会技术的成功应用。然而,在某些情况下,这种技术可能会失败,需要进行翻修手术。病例介绍:一名67岁男性在一次道路交通事故中股骨和股骨颈同侧骨折。他的损伤采用双结构治疗,包括逆行股骨干钉和动力髋螺钉。术后3个月髋螺钉从股骨头上脱落,需要翻修全髋关节置换术。手术在标准手术台上采用单阶段两部分程序进行,无需重新放置或重新包裹患者。术后无并发症,术后1年患者对结果满意,已恢复工作。结论:双假体存在下的置换髋关节置换术在技术上具有挑战性和不可预测性,并发症的风险增加。我们的手术方法为骨科医生安全执行这一复杂手术提供了一个框架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.80
自引率
8.10%
发文量
37
审稿时长
9 weeks
期刊最新文献
Bilateral lower extremity compartment syndrome after prolonged gynecological surgery in lithotomy position: a case report. The role of spinal injections towards optimizing patient selection for spinal surgery: A proof-of-concept study in 176 lower back pain patients. Implementation of the WHO surgical safety checklist in resource-limited Somalia: a new standard in surgical safety. Association between postoperative complications and hospital length of stay: a large-scale observational study of 4,495,582 patients in the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) registry. Improving surgical technical skills for emergency fixation of unstable pelvic ring fractures: an experimental study using a pelvic ring fracture simulator.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1