Reliability and Reproducibility of Analyzing 3D Transperineal Ultrasound Volumes Obtained in the First Phase of Labor - A Pilot Study.

IF 3.1 3区 医学 Q1 ACOUSTICS Ultraschall in Der Medizin Pub Date : 2023-12-01 Epub Date: 2023-01-19 DOI:10.1055/a-1957-5383
Rebecca Caspers, Elmar Stickeler, Lieven Nils Kennes, Stefanie Krawutschke, Rene Wynands, Julia Wittenborn, Linda Lecker, Friederike Schlayer, Laila Najjari
{"title":"Reliability and Reproducibility of Analyzing 3D Transperineal Ultrasound Volumes Obtained in the First Phase of Labor - A Pilot Study.","authors":"Rebecca Caspers, Elmar Stickeler, Lieven Nils Kennes, Stefanie Krawutschke, Rene Wynands, Julia Wittenborn, Linda Lecker, Friederike Schlayer, Laila Najjari","doi":"10.1055/a-1957-5383","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to investigate the reliability and reproducibility of transperineal ultrasound (TPUS) in the initial phase of labor. As TPUS is a common method, it could supplement vaginal palpation and even replace it in certain situations. In addition, we used a 4-dimensional method for the assessment of cervical effacement.</p><p><strong>Materials and methods: </strong>54 women in labor were included and underwent TPUS. The resulting images from the acquired 4D volumes were evaluated after the examination for the first time and a second time after 21 days. The measured values were cervical length, dilatation and effacement, the angle of progression (AoP), and head-perineum distance.</p><p><strong>Results: </strong>54 patients were examined. TPUS images were unable to be evaluated in 12 patients because of cervical dilatation of more than 5 cm or poor image quality. Thus, 42 measurements were included. The concordance correlation coefficients according to Lin are satisfactory overall, with one exception for cervical effacement. The accuracy component of cervical length (CCC<sub>Lin</sub>: 0.93; accuracy: 1.00), dilatation (CCC<sub>Lin</sub>: 0.93; accuracy: 1.00), and AoP (CCC<sub>Lin</sub>: 0.87; accuracy: 1.00) is excellent and still high for the head-perineum distance (CCC<sub>Lin</sub>: 0.89; accuracy: 0.96) and cervical effacement (CCC<sub>Lin</sub>: 0.77; accuracy: 0.97).</p><p><strong>Conclusion: </strong>TPUS is a valuable noninvasive tool with good diagnostic accuracy for the AoP, cervical length, and dilatation. Our study provides support for the use of TPUS to complement a vaginal examination. It should not replace a digital examination but should serve as a suitable alternative method for monitoring labor progression in the future.</p>","PeriodicalId":49400,"journal":{"name":"Ultraschall in Der Medizin","volume":" ","pages":"623-630"},"PeriodicalIF":3.1000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultraschall in Der Medizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1957-5383","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to investigate the reliability and reproducibility of transperineal ultrasound (TPUS) in the initial phase of labor. As TPUS is a common method, it could supplement vaginal palpation and even replace it in certain situations. In addition, we used a 4-dimensional method for the assessment of cervical effacement.

Materials and methods: 54 women in labor were included and underwent TPUS. The resulting images from the acquired 4D volumes were evaluated after the examination for the first time and a second time after 21 days. The measured values were cervical length, dilatation and effacement, the angle of progression (AoP), and head-perineum distance.

Results: 54 patients were examined. TPUS images were unable to be evaluated in 12 patients because of cervical dilatation of more than 5 cm or poor image quality. Thus, 42 measurements were included. The concordance correlation coefficients according to Lin are satisfactory overall, with one exception for cervical effacement. The accuracy component of cervical length (CCCLin: 0.93; accuracy: 1.00), dilatation (CCCLin: 0.93; accuracy: 1.00), and AoP (CCCLin: 0.87; accuracy: 1.00) is excellent and still high for the head-perineum distance (CCCLin: 0.89; accuracy: 0.96) and cervical effacement (CCCLin: 0.77; accuracy: 0.97).

Conclusion: TPUS is a valuable noninvasive tool with good diagnostic accuracy for the AoP, cervical length, and dilatation. Our study provides support for the use of TPUS to complement a vaginal examination. It should not replace a digital examination but should serve as a suitable alternative method for monitoring labor progression in the future.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在分娩第一阶段获得的三维经会阴超声体积分析的可靠性和可重复性-一项试点研究。
目的:本研究旨在探讨经会阴超声(TPUS)在分娩初期的可靠性和可重复性。由于tpu是一种常用的方法,在某些情况下,它可以作为阴道触诊的补充,甚至取代阴道触诊。此外,我们使用了一个四维的方法来评估宫颈糜落。材料与方法:纳入54例产妇行tpu。第一次检查后,对获取的四维体图像进行评估,21天后进行第二次评估。测量值为宫颈长度、扩张和消退、进展角(AoP)和头-会阴距离。结果:共检查54例患者。12例患者因宫颈扩张大于5cm或图像质量差而无法评价tpu图像。因此,纳入了42项测量。根据Lin的说法,一致性相关系数总体上是令人满意的,只有一个例外是宫颈消退。宫颈长度准确性分值(CCCLin: 0.93;准确性:1.00),扩张(CCCLin: 0.93;准确度:1.00),AoP (CCCLin: 0.87;准确度:1.00)是非常好的,而且对于头-会阴距离(CCCLin: 0.89;准确性:0.96)和宫颈消退(CCCLin: 0.77;准确性:0.97)。结论:tpu是一种有价值的无创工具,对AoP、宫颈长度和宫颈扩张具有良好的诊断准确性。我们的研究为使用tpu辅助阴道检查提供了支持。它不应该取代数字检查,但应该作为一种合适的替代方法来监测未来的分娩进展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ultraschall in Der Medizin
Ultraschall in Der Medizin 医学-核医学
CiteScore
5.30
自引率
8.80%
发文量
228
审稿时长
6-12 weeks
期刊介绍: Ultraschall in der Medizin / European Journal of Ultrasound publishes scientific papers and contributions from a variety of disciplines on the diagnostic and therapeutic applications of ultrasound with an emphasis on clinical application. Technical papers with a physiological theme as well as the interaction between ultrasound and biological systems might also occasionally be considered for peer review and publication, provided that the translational relevance is high and the link with clinical applications is tight. The editors and the publishers reserve the right to publish selected articles online only. Authors are welcome to submit supplementary video material. Letters and comments are also accepted, promoting a vivid exchange of opinions and scientific discussions.
期刊最新文献
The impact of real-time ultrasound guidance on ventricular catheter placement in cerebrospinal fluid shunts - a single-center study. The reliability and validity of superb microvascular imaging as a potential disease activity marker in rheumatoid arthritis. Fetal cardiovascular function in a late-onset SGA and FGR cohort: CURIOSA study. Risk-based ultrasound probe quality assurance - a single center proof-of-concept study. Evaluation of placenta and fetal lung using shear wave elastography in gestational diabetes mellitus: An innovative approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1