Worth the Wait? Time Course of Supine Shifts in Body Water Compartments on Variables of Bioelectrical Impedance Analysis.

Q3 Biochemistry, Genetics and Molecular Biology Journal of Electrical Bioimpedance Pub Date : 2022-01-01 DOI:10.2478/joeb-2022-0014
Jeremy B Ducharme, Holly Hall, Zachary J Fennel, Avadney Gerard-Osbourne, Jonathan M Houck, Chloe Clark, Ann L Gibson
{"title":"Worth the Wait? Time Course of Supine Shifts in Body Water Compartments on Variables of Bioelectrical Impedance Analysis.","authors":"Jeremy B Ducharme,&nbsp;Holly Hall,&nbsp;Zachary J Fennel,&nbsp;Avadney Gerard-Osbourne,&nbsp;Jonathan M Houck,&nbsp;Chloe Clark,&nbsp;Ann L Gibson","doi":"10.2478/joeb-2022-0014","DOIUrl":null,"url":null,"abstract":"<p><p>Bioelectrical impedance analysis (BIA) reference values are based on supine assessments. Little is known regarding the effects of time course shifts in body water compartments after assuming a supine position. The aim of this study was to characterize these effects and provide recommendations regarding the optimal waiting time to perform BIA. Thirty-eight healthy adults underwent BIA via the RJL Quantum Legacy analyzer immediately upon lying down and every 5 minutes for 15 minutes. Differences in resistance (R), reactance (Xc), intracellular (ICW), extracellular (ECW), total body water (TBW), body fat percentage (%BF), and phase angle (PhA) were assessed. There were small but significant increases in R, Xc, and %BF (all p<0.001), as well as small but significant decreases in ICW, ECW, and TBW (all p<0.001) over 15 minutes. No difference was observed for PhA (p=0.065). Average values changed over 15 minutes by +7.14Ω, +1.36Ω, -0.2L, -0.2L, -0.4L, +0.05° and +0.1% for R, Xc, ICW, ECW, TBW, PhA and %BF, respectively. BIA measurements are affected by shifts in body water compartments after assuming a supine position, but these differences lack clinical significance in healthy adults. Technicians working with healthy adults can perform BIA within 15 minutes after participants assume a supine position.</p>","PeriodicalId":38125,"journal":{"name":"Journal of Electrical Bioimpedance","volume":"13 1","pages":"96-105"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837868/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Bioimpedance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/joeb-2022-0014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

Bioelectrical impedance analysis (BIA) reference values are based on supine assessments. Little is known regarding the effects of time course shifts in body water compartments after assuming a supine position. The aim of this study was to characterize these effects and provide recommendations regarding the optimal waiting time to perform BIA. Thirty-eight healthy adults underwent BIA via the RJL Quantum Legacy analyzer immediately upon lying down and every 5 minutes for 15 minutes. Differences in resistance (R), reactance (Xc), intracellular (ICW), extracellular (ECW), total body water (TBW), body fat percentage (%BF), and phase angle (PhA) were assessed. There were small but significant increases in R, Xc, and %BF (all p<0.001), as well as small but significant decreases in ICW, ECW, and TBW (all p<0.001) over 15 minutes. No difference was observed for PhA (p=0.065). Average values changed over 15 minutes by +7.14Ω, +1.36Ω, -0.2L, -0.2L, -0.4L, +0.05° and +0.1% for R, Xc, ICW, ECW, TBW, PhA and %BF, respectively. BIA measurements are affected by shifts in body water compartments after assuming a supine position, but these differences lack clinical significance in healthy adults. Technicians working with healthy adults can perform BIA within 15 minutes after participants assume a supine position.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
值得等待吗?基于生物电阻抗分析变量的人体水区仰卧移位时间过程。
生物电阻抗分析(BIA)参考值是基于仰卧位评估。对于采取仰卧位后体内水区随时间变化的影响,我们所知甚少。本研究的目的是表征这些影响,并就BIA的最佳等待时间提出建议。38名健康成人躺下后立即通过RJL Quantum Legacy分析仪进行BIA检查,每5分钟一次,持续15分钟。评估了电阻(R)、电抗(Xc)、细胞内(ICW)、细胞外(ECW)、全身水分(TBW)、体脂率(%BF)和相角(PhA)的差异。R、Xc和%BF均有小而显著的增加
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Electrical Bioimpedance
Journal of Electrical Bioimpedance Engineering-Biomedical Engineering
CiteScore
3.00
自引率
0.00%
发文量
8
审稿时长
17 weeks
期刊最新文献
Effects of acute essential amino acid intake on post-prandial raw bioimpedance and fluid shifts between healthy young and older adults: An exploratory pilot study. Cell membrane capacitance relationship to reference-measured body composition parameters in young adult athletes. Electrical impedance myography as a marker of muscle mass in rats with simulated Anorexia Nervosa. Assessing the consistency between the anthropometric method and bioelectrical impedance analysis when calculating the Heath-Carter somatotype in people without obesity: a cross-sectional study. Predictive classification and regression models for bioimpedance vector analysis: Insights from a southern Cuban cohort.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1