The additional tibial stem extension is not mandatory for the stability of 5 mm metal block augmented tibial prosthesis construct in primary total knee arthroplasty: 5-year minimum follow-up results.

IF 4.1 Q1 ORTHOPEDICS Knee Surgery & Related Research Pub Date : 2023-02-01 DOI:10.1186/s43019-023-00174-6
Jae Joon Ryu, Yeong Hwan Kim, Choong Hyeok Choi
{"title":"The additional tibial stem extension is not mandatory for the stability of 5 mm metal block augmented tibial prosthesis construct in primary total knee arthroplasty: 5-year minimum follow-up results.","authors":"Jae Joon Ryu,&nbsp;Yeong Hwan Kim,&nbsp;Choong Hyeok Choi","doi":"10.1186/s43019-023-00174-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine whether additional stem extension for stability is necessary, we performed mid-term follow-up of patients who had been managed with 5-mm metal block augmentation for a tibial defect, where tibial prosthesis was fixed using bone cement without stem extension. Also, we evaluated clinical and radiologic results including survival rate of patients without stem extension.</p><p><strong>Methods: </strong>We retrospectively analyzed patients with tibial bone defect, had undergone primary total knee arthroplasty, and had been treated with 5-mm metal block augmentation without stem extension between March 2003 and September 2013. Among 74 patients (80 cases), 47 patients (52 cases) were followed up for at least 5 years.</p><p><strong>Results: </strong>Mean flexion contracture improved from 8.8° (0-40°) preoperatively to 0.4° (-5° to 15°) at final follow-up (P < 0.01), but there was no significant change in the mean angle of great flexion: 124.6° (75-150°) preoperatively and 126.2° (90-145°) at final follow-up (P = 0.488). Mean range of motion improved from 115.8° (35-150°) preoperatively to 125.5° (90-145°) at final follow-up (P < 0.01). Mean knee score improved from 38.7 points (0-66 points) preoperatively to 93.2 points (79-100 points) at final follow-up (P < 0.01), and mean functional score also improved from 50.4 points (10-70 points) preoperatively to 81.8 points (15-100 points) at final follow-up (P < 0.01). The mean postoperative Western Ontario and McMaster University osteoarthritis score was 19.5 points (0-66.0 points). The mean femorotibial angle was corrected from 9.0° varus (23.0° varus-6.3° valgus) preoperatively to 5.5° valgus (2.2° varus-11.1° valgus) at final follow-up (P < 0.01). There was no change in the mean β-angle, which was 90.7° (87.2-94.9°) immediately postoperative and 90.8° (87.2-94.9°) at final follow-up (P = 0.748) and in the mean δ-angle, which was 86.2° (81.3-90.0°) immediately postoperative and 87.2° (83.1-96.5°) at final follow-up (P = 0.272). Radiolucent lines (RLL) were observed in ten cases (26.3%), and the mean RLL scores at final follow-up were 0.34 points (0-3 points) in the anteroposterior view and 0.42 points (0-6 points) in the lateral view. Scores for the RLL were ≤ 4 points in 36 cases, 5-9 points in two cases. Revision surgery due to aseptic loosening (three cases) is rarely required, and the Kaplan-Meier survival rate at 10 postoperative years was 96.4% CONCLUSION: When performing 5-mm metal block augmentation for a proximal tibial defect, no additional tibial stem extension can be a good surgical option for the stability of tibial prosthetic construct and mid-term clinical and radiologic results.</p><p><strong>Level of evidence: </strong>IV.</p>","PeriodicalId":17886,"journal":{"name":"Knee Surgery & Related Research","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890779/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee Surgery & Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43019-023-00174-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: To determine whether additional stem extension for stability is necessary, we performed mid-term follow-up of patients who had been managed with 5-mm metal block augmentation for a tibial defect, where tibial prosthesis was fixed using bone cement without stem extension. Also, we evaluated clinical and radiologic results including survival rate of patients without stem extension.

Methods: We retrospectively analyzed patients with tibial bone defect, had undergone primary total knee arthroplasty, and had been treated with 5-mm metal block augmentation without stem extension between March 2003 and September 2013. Among 74 patients (80 cases), 47 patients (52 cases) were followed up for at least 5 years.

Results: Mean flexion contracture improved from 8.8° (0-40°) preoperatively to 0.4° (-5° to 15°) at final follow-up (P < 0.01), but there was no significant change in the mean angle of great flexion: 124.6° (75-150°) preoperatively and 126.2° (90-145°) at final follow-up (P = 0.488). Mean range of motion improved from 115.8° (35-150°) preoperatively to 125.5° (90-145°) at final follow-up (P < 0.01). Mean knee score improved from 38.7 points (0-66 points) preoperatively to 93.2 points (79-100 points) at final follow-up (P < 0.01), and mean functional score also improved from 50.4 points (10-70 points) preoperatively to 81.8 points (15-100 points) at final follow-up (P < 0.01). The mean postoperative Western Ontario and McMaster University osteoarthritis score was 19.5 points (0-66.0 points). The mean femorotibial angle was corrected from 9.0° varus (23.0° varus-6.3° valgus) preoperatively to 5.5° valgus (2.2° varus-11.1° valgus) at final follow-up (P < 0.01). There was no change in the mean β-angle, which was 90.7° (87.2-94.9°) immediately postoperative and 90.8° (87.2-94.9°) at final follow-up (P = 0.748) and in the mean δ-angle, which was 86.2° (81.3-90.0°) immediately postoperative and 87.2° (83.1-96.5°) at final follow-up (P = 0.272). Radiolucent lines (RLL) were observed in ten cases (26.3%), and the mean RLL scores at final follow-up were 0.34 points (0-3 points) in the anteroposterior view and 0.42 points (0-6 points) in the lateral view. Scores for the RLL were ≤ 4 points in 36 cases, 5-9 points in two cases. Revision surgery due to aseptic loosening (three cases) is rarely required, and the Kaplan-Meier survival rate at 10 postoperative years was 96.4% CONCLUSION: When performing 5-mm metal block augmentation for a proximal tibial defect, no additional tibial stem extension can be a good surgical option for the stability of tibial prosthetic construct and mid-term clinical and radiologic results.

Level of evidence: IV.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在初次全膝关节置换术中,5mm金属块增强胫骨假体结构的稳定性并不是强制性的额外胫骨柄延伸:5年最小随访结果。
目的:为了确定是否需要额外的柄延伸以保持稳定,我们对胫骨缺损患者进行了5毫米金属块增强术,其中胫骨假体使用骨水泥固定而不需要柄延伸。此外,我们评估了临床和放射学结果,包括无茎延伸患者的生存率。方法:回顾性分析2003年3月至2013年9月间,行一期全膝关节置换术并行5mm金属块增强术(无膝关节柄延长)的胫骨骨缺损患者。74例(80例)患者中,随访5年以上的有47例(52例)。结果:平均屈曲挛缩从术前8.8°(0-40°)改善到最终随访时的0.4°(-5°至15°)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.40
自引率
0.00%
发文量
0
期刊最新文献
A novel practical method to predict anterior cruciate ligament hamstring graft size using preoperative MRI Evaluating the accuracy and relevance of ChatGPT responses to frequently asked questions regarding total knee replacement Phenotype-considered kinematically aligned total knee arthroplasty for windswept-deformity-associated osteoarthritis: surgical strategy and clinical outcomes Analysis of radiographic factors affecting the significant differences in knee alignment between hip-to-talus and hip-to-calcaneus radiographs after opening-wedge high tibial osteotomy Ramp lesion in anterior cruciate ligament injury: a review of the anatomy, biomechanics, epidemiology, and diagnosis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1