Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometric method for the determination of 25 psychoactive drugs in cerumen and its application to real postmortem samples.
{"title":"Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometric method for the determination of 25 psychoactive drugs in cerumen and its application to real postmortem samples.","authors":"Orthodoxia Mastrogianni, Amvrosios Orfanidis, Evdokia Brousa, Dimitrios-Phaedon Kevrekidis, Heleni Zagelidou, Nikolaos Raikos","doi":"10.1007/s11419-022-00640-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In the present study, a method for the detection of 25 psychoactive substances in cerumen was developed and validated. This method targets opiates, cocaine, antidepressants, benzodiazepines, antipsychotics and antiparkinsons.</p><p><strong>Methods: </strong>Analysis was performed on a SCIEX Triple Quad 6500+ system after liquid-liquid extraction. Methanol with 1% acetic acid was chosen as the extraction solvent. After the addition of the solvent, samples were vortexed, sonicated, centrifuged and directly injected into the liquid chromatography-tandem mass spectrometry system.</p><p><strong>Results: </strong>The method was found to be selective and sensitive (limit of detection: 0.017 ng-0.33 ng/mg), the assay was linear for all analytes with linear regression coefficient ranging 0.9911-1.00. The values for intra-assay precision was between 4.34 and 14.6% and inter-assay precision between 5.81 and 17.7%, with accuracy within the acceptable criteria for all analytes. All analytes in cerumen specimens were stable for 48 h at 4 °C and 72 h at - 20 °C, whilst no significant matrix effect or carryover was observed. Applicability was proven by analyzing cerumen samples from 25 deceased with a history of drug abuse. All analytes were detected in real samples, thus confirming the sensitivity of the developed method.</p><p><strong>Conclusions: </strong>According to our knowledge, it is the first time that a method for the simultaneous detection of 25 psychoactive drugs in cerumen was developed, fully validated and finally applied to 25 postmortem samples.</p>","PeriodicalId":12329,"journal":{"name":"Forensic Toxicology","volume":"41 1","pages":"94-104"},"PeriodicalIF":2.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11419-022-00640-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 4
Abstract
Purpose: In the present study, a method for the detection of 25 psychoactive substances in cerumen was developed and validated. This method targets opiates, cocaine, antidepressants, benzodiazepines, antipsychotics and antiparkinsons.
Methods: Analysis was performed on a SCIEX Triple Quad 6500+ system after liquid-liquid extraction. Methanol with 1% acetic acid was chosen as the extraction solvent. After the addition of the solvent, samples were vortexed, sonicated, centrifuged and directly injected into the liquid chromatography-tandem mass spectrometry system.
Results: The method was found to be selective and sensitive (limit of detection: 0.017 ng-0.33 ng/mg), the assay was linear for all analytes with linear regression coefficient ranging 0.9911-1.00. The values for intra-assay precision was between 4.34 and 14.6% and inter-assay precision between 5.81 and 17.7%, with accuracy within the acceptable criteria for all analytes. All analytes in cerumen specimens were stable for 48 h at 4 °C and 72 h at - 20 °C, whilst no significant matrix effect or carryover was observed. Applicability was proven by analyzing cerumen samples from 25 deceased with a history of drug abuse. All analytes were detected in real samples, thus confirming the sensitivity of the developed method.
Conclusions: According to our knowledge, it is the first time that a method for the simultaneous detection of 25 psychoactive drugs in cerumen was developed, fully validated and finally applied to 25 postmortem samples.
期刊介绍:
The journal Forensic Toxicology provides an international forum for publication of studies on toxic substances, drugs of abuse, doping agents, chemical warfare agents, and their metabolisms and analyses, which are related to laws and ethics. It includes original articles, reviews, mini-reviews, short communications, and case reports. Although a major focus of the journal is on the development or improvement of analytical methods for the above-mentioned chemicals in human matrices, appropriate studies with animal experiments are also published.
Forensic Toxicology is the official publication of the Japanese Association of Forensic Toxicology (JAFT) and is the continuation of the Japanese Journal of Forensic Toxicology (ISSN 0915-9606).